RIGIDFIX BIOCRYL 2.7MM BTB (210815), FEMORAL 3.3MM ST (210816), AND TIBIAL 3.3MM ST (210817) CROSS PIN KITS
K091041 · Depuy Mitek, A Johnson & Johnson Company · MAI · Aug 7, 2009 · Orthopedic
Device Facts
Record ID
K091041
Device Name
RIGIDFIX BIOCRYL 2.7MM BTB (210815), FEMORAL 3.3MM ST (210816), AND TIBIAL 3.3MM ST (210817) CROSS PIN KITS
Applicant
Depuy Mitek, A Johnson & Johnson Company
Product Code
MAI · Orthopedic
Decision Date
Aug 7, 2009
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 888.3030
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
RigidFix Biocryl Cross Pin Kits The RigidFix Biocryl 2.7 mm BTB Cross Pin Kit is intended femoral and/or tibial fixation of autograft or allograft ACL Bone-tendon-bone grafts. The RigidFix Biocryl Fcmoral 3.3 mm ST Cross Pin Kit is intended for femoral fixation of autograft or allograft ACL soft tissue grafts (semitendinosus and gracillis). The RigidFix Biocryl Tibial 3.3 mm ST Cross Pin Kit is intended for tibial fixation of autograft or allograft ACL soft tissue grafts (semitendinosus and gracillis). BioIntrafix Tibial Tapered Sheaths and Screws The BioIntrafix Tibial Screw and Tibial Sheath are intended for fixation of soft tissue grafts during cruciate ligament reconstruction. Biocryl Interference Screws The Biocryl Interference Screw is indicated for the fixation of soft tissue grafts gr bone-tendon-bone grafts during cruciate ligament reconstruction surgeries of the knee.
Device Story
Absorbable orthopedic implants used for graft fixation in ACL reconstruction; includes cross pin kits, tibial tapered sheaths/screws, and interference screws. Implants manufactured from Biocryl (15% beta-TCP/85% PLA composite). Used by surgeons in clinical settings to secure grafts to femur or tibia. Implants are sterile, single-use; associated with reusable stainless steel instrumentation (guides, trocars, rods) for placement. Provides mechanical fixation of grafts to bone to facilitate healing. Submission supports 3-year shelf life based on 36-month stability study.
Clinical Evidence
No clinical data. Substantial equivalence supported by identical indications, materials, and design to predicates, with performance and safety data previously established in predicate 510(k) submissions.
Technological Characteristics
Absorbable implants composed of 15% beta-tricalcium phosphate (beta-TCP) and 85% polylactic acid (PLA) polymer. Includes cannulated, threaded fasteners and cross pins. Reusable instrumentation (guides, trocars) made of stainless steel. Sterile, single-patient use implants; non-sterile, reusable instruments. No software or electronic components.
Indications for Use
Indicated for fixation of autograft or allograft bone-tendon-bone or soft tissue (semitendinosus and gracillis) grafts during knee cruciate ligament reconstruction surgeries.
Regulatory Classification
Identification
Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.
Predicate Devices
BioIntrafix Tibial Tapered Sheaths and Screws (K032167)
{0}------------------------------------------------
## SECTION 2 – 510(k) SUMMARY
Raynham, MA 02767
DePuy Mitek, Inc.
Regulatory Affairs Specialist
a Johnson & Johnson company 325 Paramount Drive Raynham, MA 02767, USA Telephone: 508-977-3966
Zheng Liu
RigidFix BiocryI Cross Pin Kits BioIntrafix Tibial Tapered Sheaths and Screws Biocryl Interference Screws
AUG 0 7 2009
DePuy Mitek Submitter's Name and a Johnson & Johnson company Address: 325 Paramount Drive
Contact Person
Name of Medical Device
Facsimile: 508-977-6955 e-mail: zliu8@its.jnj.com Classification Name: Single/multiple component metallic bone fixation appliances and accessories Common/Usual Name: Bone Anchor RigidFix Biocryl Cross Pin Kits Proprietary Name: BioIntrafix Tibial Tapered Sheaths and Screws Biocryl Interference Screws
Substantial Equivalence
and Restorative Deyice
BioIntrafix Tibial Tapered Sheaths and Screws are substantially equivalent to: (Division Sign-Off) Division of Surgical, Orthopedic,
트
- K032167 BioIntrafix Tibial Tapered Sheaths and Screws (October 이 15, 2003).
RigidFix Biocryl Cross Pin Kits are substantially equivalent to:
K090669 RigidFix Biocryl Cross Pin Kits (April 03, 2009).
Biocryl Interference Screws are substantially equivalent to:
510(k) Number
- K013572 Biocryl Interference Screws (March 14, 2002).
Premarket Notification: Traditional
RigidFix Biocryl Cross Pin Kits, Biocryl Interference Screws, BioIntrafix Tibial Tapered Sheaths and Screws
{1}------------------------------------------------
| Device Classification | These devices carry an FDA product code MAI, and subsequent code<br>HTY, and is classified as single/multiple component metallic bone<br>fixation appliances and accessories under 21 CFR 888.3030. |
|------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Device Description | RigidFix Biocryl Cross Pin Kits |
| | The proposed RigidFix Biocryl 2.7 mm BTB Cross Pins are<br>absorbable implants manufactured from "Biocryl" (15% ß-TCP/<br>85%PLA) material. The proposed RigidFix Biocryl 2.7 mm BTB Cross<br>Pins are used for the fixation of bone-tendon-bone grafts to the femur<br>and the tibia in Anterior Cruciate Ligament (ACL) reconstruction. A<br>total of four RigidFix Biocryl 2.7 mm BTB Cross Pins are used to<br>complete the reconstruction: two on the femur and two on the tibia. |
| | The proposed RigidFix Biocryl Femoral 3.3 mm ST Cross Pins are<br>absorbable implants manufactured from "Biocryl" (15% ß-TCP/<br>85%PLA) material. The proposed RigidFix Biocryl Femoral 3.3 mm<br>ST Cross Pins are used for the fixation of soft tissue (semitendinosus<br>and gracillis) grafts to the femur in ACL reconstruction. Two RigidFix<br>Biocryl Femoral 3.3 mm ST Cross Pins are used to complete the repair. |
| | The proposed RigidFix Biocryl Tibial 3.3 mm ST Cross Pins are<br>absorbable implants manufactured from "Biocryl" (15% ß-TCP/<br>85%PLA) material. The proposed RigidFix biocryl Tibial 3.3 mm ST<br>Cross Pins are used for the fixation of soft tissue (semitendinosus and<br>gracillis) grafts to the femur in ACL reconstruction. Two RigidFix<br>Biocryl Tibial 3.3 mm ST Cross Pins are used to complete the repair. |
| (Division Sign-Off)<br>Division of Surgical, Orthopedic,<br>and Restorative Devices<br>510(k) Number | Each RigidFix Biocryl Cross Pin Kit is provided sterile and is for single<br>patient use only. |
| | Except for the Interlocking Trocar and Sleeve assemblies that are<br>packaged in the RigidFix kits with the RigidFix Biocryl pins, other<br>reusable instrumentation is offered separately to assist in the placement<br>of the RigidFix Biocryl pins. The instrumentation consists of Tibial<br>Guide Frame, Tibial Rods, Long Stepped Trocar, Trocar Trial, Guide<br>Block Head Thumb Screw, Probe, Short Stepped Trocar, Tibial Pin<br>Insertion Rod and Femora/Tibial Rod Thumb Screw. These devices are<br>all stainless steel, non-sterile, reusable devices. In accordance to CFR<br>§888.4540, these are Class I devices and, therefore, are exempt from<br>510(k) premarketing notification procedures. Validated cleaning and<br>sterilization instructions are provided for those instruments. |
| | BioIntrafix Tibial Tapered Sheaths and Screws |
The DePuy Mitek BioIntrafix Tibial Tapered Screws and BioIntrafix Tibial Sheaths are absorbable implants made from a composite of absorbable Polylactic Acid (PLA) Polymer and Tricalcium Phosphate (TCP). They are used to secure soft tissue grafts to the bone during
Premarket Notification: Traditional RigidFix Biocryl Cross Pin Kits, Biocryl Interference Screws, BioIntrafix Tibial Tapered Sheaths and Screws
{2}------------------------------------------------
K091041
cruciate ligament reconstruction. The BioIntrafix Tibial Tapered Screws and BioIntrafix Tibial Sheaths are supplied sterile ready to use. The tie tensioner is a non-sterile, reusable instrument used to apply and measure tension on the graft.
#### Biocryl Interference Screws
The DePuy Mitek Biocryl Interference Screw is an absorbable, tapered, cannulated, threaded fastener for use in interference fixation of soft tissue grafts or bone-tendon grafts. The Interference Screw is made from a composite made of absorbable Poly Lactic Acid.(PLA) polymer and Tricalcium Phosphate (TCP). The Biocryl Interference Screw is packaged one per pouch.
#### RigidFix Biocryl Cross Pin Kits
The RigidFix Biocryl 2.7 mm BTB Cross Pin Kit is intended for femoral and/or tibial fixation of autograft or allograft ACL Bonetendon-bone grafts.
The RigidFix Biocryl Femoral 3.3 mm ST Cross Pin Kit is intended for femoral fixation of autograft or allograft ACL soft tissue grafts (semitendinosus and gracillis).
The RigidFix Biocryl Tibial 3.3 mm ST Cross Pin Kit is intended for tibial fixation of autograft or allograft ACL soft tissue grafts (semitendinosus and gracillis).
### BioIntrafix Tibial Tapered Sheaths and Screws
The BioIntrafix Tibial Screw and Tibial Sheath are intended for fixation of soft tissue grafts during cruciate ligament reconstruction.
#### Biocryl Interference Screws
The Biocryl Interference Screw is indicated for the fixation of soft tissue grafts or bone-tendon-bone grafts during cruciate ligament reconstruction surgeries of the knee.
This premarket notification is submitted to have the protocol of the 36month stability study reviewed to support a 3-year shelf life claim on the proposed products (i.e. RigidFix Biocryl Cross Pin Kits, BioIntrafix Tibial Tapered Sheaths and Screws, and Biocryl Interference Screws). No other changes have been made to the predicate devices.
The proposed products have the same indication statements and the same technological characteristics (e.g., design, materials, etc.) as that of the respective predicate products. In addition, the descriptive characteristics are precise enough to establish substantial equivalence
#### Premarket Notification: Traditional
Safety and Performance
RigidFix Biocryl Cross Pin Kits, Biocryl Interference Screws, BioIntrafix Tibial Tapered Sheaths and Screws
### Indications for Use
{3}------------------------------------------------
K091041
between the proposed products and their respective predicates. Therefore, additional safety and performance testing on the proposed products are not necessary.
Results of performance and safety testing have been submitted in the predicate 510(k)'s (i.e. K090669 for RigidFix Biocryl Cross Pin Kits, K032167 for BioIntrafix Tibial Sheaths and Screws, and K013572 for Biocryl Interference Screws) and have demonstrated that the devices are suitable for their intended use.
Based on the identical indications for use and technological characteristics as compared to the predicate devices, the proposed RigidFix Biocryl Cross Pin Kits, BioIntrafix Tibial Sheaths and Screws, and Biocryl Interference Screws have shown to be substantially equivalent to their respective predicate devices under the Federal Food, Drug and Cosmetic Act.
DK
(Division Sign-Off) Division of Surgical, Orthopedic, and Restorative Devices
510(k) Number 1109/04/
Premarket Notification: Traditional RigidFix Biocryl Cross Pin Kits, Biocryl Interference Screws, BioIntrafix Tibial Tapered Sheaths and Screws
{4}------------------------------------------------
## DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/4/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized depiction of an eagle or bird-like figure with three wing-like strokes, positioned above a wavy, ribbon-like element. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the bird symbol.
Food and Drug Administration 10903 New Hampshire Avenue Document Mail Center - WO66-G609 Silver Spring, MD 20993-0002
DePuy Mitek A Johnson & Johnson Company % Ms. Zheng Liu Regulatory Affairs Specialist 325 Paramount Drive Raynham, Massachusetts 02767
# AUG 0 7 2009
Re: K091041
Trade/Device Name: RigidFix Biocryl Cross Pin Kits, BioIntrafix Tibial Tapered Sheaths and Screws, Biocryl Interference Screws
Regulation Number: 21 CFR 888.3030
Regulation Name: Single/multiple component metallic bone fixation appliances and
accessories
Regulatory Class: II Product Code: MAI, HTY, HWC Dated: July 15, 2009
Received: July 16, 2009
### Dear Ms. Liu
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
{5}------------------------------------------------
Page 2- Ms. Zheng Liu
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely yours,
Mark N. Melkerson
Director Division of Surgical, Orthopedic, and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{6}------------------------------------------------
K091041
# Indications for Use
510(k) Number (if known):
Device Name: RigidFix Biocryl Cross Pin Kits BioIntrafix Tibial Tapered Sheaths and Screws Biocryl Interference Screws
Indications for Use:
#### RigidFix Biocryl Cross Pin Kits
The RigidFix Biocryl 2.7 mm BTB Cross Pin Kit is intended femoral and/or tibial fixation of autograft or allograft ACL Bone-tendon-bone grafts.
The RigidFix Biocryl Fcmoral 3.3 mm ST Cross Pin Kit is intended for femoral fixation of autograft or allograft ACL soft tissue grafts (semitendinosus and gracillis).
The RigidFix Biocryl Tibial 3.3 mm ST Cross Pin Kit is intended for tibial fixation of autograft or allograft ACL soft tissue grafts (semitendinosus and gracillis).
BioIntrafix Tibial Tapered Sheaths and Screws
The BioIntrafix Tibial Screw and Tibial Sheath are intended for fixation of soft tissue grafts during cruciate ligament reconstruction.
#### Biocryl Interference Screws
The Biocryl Interference Screw is indicated for the fixation of soft tissue grafts gr bone-tendon-bone grafts during cruciate ligament reconstruction surgeries of the knee.
| (Division Sign-Off) |
|-----------------------------------|
| Division of Surgical, Orthopedic, |
| and Restorative Devices |
| /09/04/ |
Prescription Use X (Part 21 CFR 801 Subpart D) AND/OR
51Qtkz Npggccccuntor Use (21 CFR 807 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Page 1 of_1
Premarket Notification: Traditional RigidFix Biocryl Cross Pin Klts, Biocryl Interference Screws, BioIntrafix Tibial Tapered Sheaths and Screws
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Report an issue or suggest a feature
Spot a broken citation, a wrong extraction, a missing document, or something you wish this app did? Tell us — no account needed.
or drag and drop files here
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.