K083454 · U.S. Safety Syringes Co., Inc. · FOZ · Dec 4, 2008 · General Hospital
Device Facts
Record ID
K083454
Device Name
NUOVOCATH
Applicant
U.S. Safety Syringes Co., Inc.
Product Code
FOZ · General Hospital
Decision Date
Dec 4, 2008
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 880.5200
Device Class
Class 2
Attributes
Therapeutic, 3rd-Party Reviewed
Intended Use
The NUOVOcath IV Catheter in size 14G to 26 G is used for venous access for the infusion of I.V. fluids, medicines into the circulating system. Caution: Federal law restricts this device to sale by or on the order of physician.
Device Story
NUOVOcath IV Catheter provides venous access for infusion of fluids and medications into circulatory system. Device consists of catheter assembly for insertion into patient veins. Used in clinical settings by healthcare professionals. Output is established venous access path. Benefits include reliable delivery of therapeutic agents.
Clinical Evidence
No clinical data provided; device is a standard intravascular catheter.
Technological Characteristics
Intravascular catheter; sizes 14G to 26G; intended for venous access. Class II device (21 CFR 880.5200, Product Code FOZ).
Indications for Use
Indicated for patients requiring venous access for the infusion of IV fluids and medications. Available in sizes 14G to 26G. Prescription use only.
Regulatory Classification
Identification
An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or administer fluids intravenously. The device may be constructed of metal, rubber, plastic, or a combination of these materials.
Related Devices
K042504 — CATHY STERILE DISPOSABLE I.V. CANNULA WITH CATHETER · Myco Medical Supplies, Inc. · Jan 19, 2006
K980994 — IV ADMINISTRATION SETS WITH NEEDLE ACCESS DEVICES · Venetec Intl., Inc. · May 29, 1998
K990236 — MODIFICATION OF JELCO*,JELCO*-W AND JELCO* PLUS I.V. CATHETERS, CATHLON* I.V. CATHETERS, OPTIVA* I.V. CATHETERS, PROTECT · Johnson & Johnson Medical, Div. of Ethicon, Inc. · Aug 20, 1999
K081123 — NEXUS I.V. NEEDLESS ACCESS CANNULA FOR INTRAVASCULAR ADMINISTRATION SETS · Nexus Medical, LLC · Nov 14, 2008
K162951 — TUBETECH IV Administration Set · Douglas Medical Products, Inc. · Jul 28, 2017
Submission Summary (Full Text)
{0}------------------------------------------------
### DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/0/Picture/1 description: The image is a circular seal for the U.S. Department of Health & Human Services. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged around the top half of the circle. The bottom half of the circle contains a stylized emblem, possibly representing an eagle or other bird, with abstract lines forming its wings and body.
#### Public Health Service
## DEC 0 4 2008
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
U.S. Safety Syringes Company, Incorporated C/O Mr. Ned Devine Responsible Third Party Official Underwriters Laboratories, Incorporated 333 Pfingsten Road Northbrook, Illinois 60062
Re: K083454
Trade/Device Name: NUOVOCath IV Catheter Regulation Number: 21 CFR 880.5200 Regulation Name: Intravascular Catheter Regulatory Class: II Product Code: FOZ Dated: November 19, 2008 Received: November 21, 2008
Dear Mr. Devine:
We have reviewed vour Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{1}------------------------------------------------
### Page 2 - Mr. Devine
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket Surveillance at 240-276-3474. For questions regarding the reporting of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at 240-276-3464. You may obtain other general information on vour responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely vours.
Chiu S. Liu, Ph.D.
Chiu S. Lin, Ph. D Division Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
### Enclosure
{2}------------------------------------------------
Indications for Use
# 510(k) Number (if known): KOS 3454
Device Name: NUOVOCATH IV CATHETER
Indications for Use:
The NUOVOcath IV Catheter in size 14G to 26 G is used for venous access for the infusion of I.V. fluids, medicines into the circulating system.
Caution: Federal law restricts this device to sale by or on the order of physician.
Prescription use X (Part 21 CFR 801 Subpart D)
AND/OR
Over - The - Counter Use (21 CFR 807 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Anthen O. nratin
(Division Sign-Off)
Division of Anesthesiology, General Hospital Infection Control, Dental Devices
510(k) Number: _______________________________________________________________________________________________________________________________________________________________
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.