EndoWave Infusion System

K080392 · Ekos Corp. · QEY · Apr 30, 2008 · Cardiovascular

Device Facts

Record IDK080392
Device NameEndoWave Infusion System
ApplicantEkos Corp.
Product CodeQEY · Cardiovascular
Decision DateApr 30, 2008
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 870.5150
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The EndoWave Infusion System is intended for the controlled and selective infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature.

Device Story

EndoWave Infusion System; disposable infusion catheter with removable ultrasound core; control instrument generates/delivers energy. Catheter features multiple side holes in treatment zone; ultrasound core contains up to 30 elements; thermal sensors monitor temperature. Used in clinical setting by physicians for peripheral vasculature infusion. Device delivers fluids while ultrasound energy potentially enhances thrombolytic effect. Modification involves revised acoustic protocol; system maintains original technological characteristics.

Clinical Evidence

Bench testing only. Testing confirmed revised acoustic protocol remains safe and ultrasound core operates as required.

Technological Characteristics

Disposable infusion catheter with removable ultrasound core; instrument for energy delivery. Up to 30 ultrasound elements; thermal sensors for temperature monitoring. Modification: revised acoustic protocol.

Indications for Use

Indicated for patients requiring controlled, selective infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature.

Regulatory Classification

Identification

An embolectomy catheter is a balloon-tipped catheter that is used to remove thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to another.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K080392 page 1 of 1 SPECIAL 510(k) Notification EndoWave™ Infusion System #### 510(k) Summary Section 4. General Provisions Submitter's Name and Address: EKOS Corporation 11911 North Creek Parkway South Bothell, WA 98011 Catheter, Continuous Flush (KRA) Contact Person: Jocelyn Kersten 425-415-3132 425-415-3102 (fax) jkersten@EKOSCORP.com Classification Name: Regulation Number: 21 CFR §870.1210 Continuous Flush Catheter Proprietary Name: Name of Predicate Device: Common or Usual Name: EndoWave Infusion System EndoWave Infusion System K072507, K062508 510(k) Reference No .: ### Device Description The system consists of a disposable infusion catheter with removable ultrasound core and an instrument that generates and controls the delivery of energy to the catheter. The infusion catheter contains multiple side holes distributed over the length of the treatment zone. The ultrasound core contains up to 30 ultrasound elements, evenly spaced over the treatment zone. Thermal sensors in the treatment zone monitor catheter temperature. ### Intended Use The EndoWave Infusion System is intended for the controlled and selective infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature. ## Summary of Technological Characteristics The device modification described in this notification does not affect the technological characteristics for the EndoWave Infusion System. ### Test Summary Testing confirmed the revised acoustic protocol remains safe and the ultrasound core will operate as required with the new protocol. # APR 3 0 2008
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...