NAVIGATOR ANESTHESIA DELIVERY SYSTEM, MODEL 0998-00-3024-01

K080175 · Datascope Corp., Patient Monitoring Division · BSZ · Jun 9, 2008 · Anesthesiology

Device Facts

Record IDK080175
Device NameNAVIGATOR ANESTHESIA DELIVERY SYSTEM, MODEL 0998-00-3024-01
ApplicantDatascope Corp., Patient Monitoring Division
Product CodeBSZ · Anesthesiology
Decision DateJun 9, 2008
DecisionSESE
Submission TypeAbbreviated
Regulation21 CFR 868.5160
Device ClassClass 2
AttributesTherapeutic, Pediatric

Intended Use

The Navigator Anesthesia Delivery System is a device used to administer to a patient, continuously or intermittently, a general inhalation anesthetic and to maintain a patient's ventilation. The Navigator System is intended for use by licensed clinicians, for patient requiring anesthesia within a health care facility, and can be used in both adult and pediatric populations.

Device Story

Continuous flow anesthesia system; provides manual or automatic ventilation; delivers fresh gas and anesthetic agents. Features include dual flow tubes, two vaporizers, and heated breathing system to minimize condensation. Supports multiple ventilation modes (CMV, PCV, SIMV, PSV) with electronic PEEP. Designed to prevent hypoxic mixtures and accidental flow knob movement; includes battery backup for AC power failure. Used by licensed clinicians in healthcare facilities. Output includes ventilation monitoring and gas delivery; assists clinicians in maintaining patient anesthesia and respiratory support during procedures.

Clinical Evidence

No clinical data. Performance testing included bench testing for safety, performance, and electromagnetic compatibility standards, as well as risk analysis and software validation per FDA guidance.

Technological Characteristics

Continuous flow anesthesia delivery system; electronic PEEP; dual flow tubes; two vaporizers; heated breathing system. Includes battery backup. Software-controlled ventilation modes (CMV, PCV, SIMV, PSV).

Indications for Use

Indicated for adult and pediatric patients requiring general inhalation anesthesia and ventilation maintenance within a healthcare facility.

Regulatory Classification

Identification

A gas machine for anesthesia is a device used to administer to a patient, continuously or intermittently, a general inhalation anesthetic and to maintain a patient's ventilation. The device may include a gas flowmeter, vaporizer, ventilator, breathing circuit with bag, and emergency air supply. A gas machine for analgesia is a device used to administer to a patient an analgesic agent, such as a nitrous oxide-oxygen mixture (maximum concentration of 70 percent nitrous oxide).

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image shows the word "Datascope" in a stylized font. Above the word is a curved line that starts thick on the left and thins out as it moves to the right, creating an arc over the word. The "®" symbol is located to the right of the word. innovation is the best medicinc Ko80175 510(k) Summary Navigator Anesthesia Delivery System This 510(K) Summary is provided in accordance with 21 CFR 807.92. JUN - 9 2008 | Date: | January 23, 2008 | |------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Submitter: | Datascope Corp.<br>800 MacArthur Blvd.<br>Mahwah, NJ 07430<br>Contact: Kathleen Kramer<br>Manager, Clinical and Regulatory Affairs<br>Telephone: 201-995-8169<br>Facsimile: 201-995-8605 | | Device Trade Name: | Navigator Anesthesia Delivery System | | Common Name: | Gas-Machine, Anesthesia | | Device Classification: | Anesthesiology<br>21 CFR 868.5160, Product code: BSZ, Class: II | | Predicate Devices: | Modular Anesthesia System, Heyer America Inc. (K001988) and<br>Avance Anesthesia System, GE Datex-Ohmeda (K071142). | | Device description: | The Navigator Anesthesia Delivery System is a continuous flow<br>anesthesia system which offers manual or automatic ventilation,<br>easily adjustable fresh gas delivery, anesthetic agent delivery,<br>ventilation monitoring, convenient ergonomics, and state-of-the-art<br>safety systems. The Navigator System is designed to decrease the<br>risk of hypoxic mixtures and the inadvertent movement of the air<br>flow control knobs. Additionally, the Navigator provides battery<br>power in the event of an AC power outage.<br>Multiple ventilation modes, i.e., CMV, PCV, SIMV and PSV, are<br>offered by the Navigator System with electronic PEEP available in<br>each of the modes. The fresh gas dosing subsystem offers features<br>of a traditional anesthesia system along with dual flow tubes which<br>display the gas flows at all times. The Navigator contains two<br>vaporizers and a heated breathing system to minimize<br>condensation and return moisture to the patient. | . : 上 501(K) Summary : : 1 . : {1}------------------------------------------------ Image /page/1/Picture/0 description: The image shows the word "Datascope" in a serif font. Above the word is a curved line that starts thick and tapers off to the right. A small registration mark is present to the right of the word. innovation is the best medicine | Indications for Use: | The Navigator Anesthesia Delivery System is a device used to administer to a patient, continuously or intermittently, a general inhalation anesthetic and to maintain a patient's ventilation.<br>The Navigator System is intended for use by licensed clinicians, for patient requiring anesthesia within a health care facility, and can be used in both adult and pediatric populations. | |-----------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Technological Comparison to Predicate Device: | The Navigator System is technically equivalent to Heyer America's Modular Anesthesia System (K001988) and GE Datex-Ohmeda's Avance Anesthesia System (K071142) with respect to indications for use and technical/performance characteristics. | | Summary of Performance Testing: | The Navigator System has been tested and found to be in compliance with recognized safety, performance and electromagnetic compatibility standards.<br>A risk analysis has been developed to identify potential hazards and document the mitigation of the hazards. The device's software has been validated in accordance with the requirements set forth in the FDA Guidance for the Content of Premarket Submissions for Software Contained in Medical Devices (May 11, 2005). | | Conclusion: | Based on the above description, technological comparison, performance testing and the supporting documentation it can be concluded that the Navigator Anesthesia Delivery System is safe, effective and substantially equivalent to the predicate device. | : . {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle-like symbol with three wing-like shapes. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the symbol. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 Ms. Kathleen Kramer Manager, Clinical & Regulatory Affairs Datascope Corporation Patient Monitoring Division 800 MacArthur Boulevard Mahwah, New Jersey 07430 JUN - 9 2008 Re: K080175 Trade/Device Name: Navigator Anesthesia Delivery System Regulation Number: 21 CFR 868.5160 Regulation Name: Gas Machine for Anesthesia or Analgesia Regulatory Class: II Product Code: BSZ Dated: May 16, 2008 Received: May 19, 2008 Dear Ms. Kramer: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA), You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {3}------------------------------------------------ Page 2 - Ms. Kramer Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours, Chih-Lin, Ph.D. Chiu Lin, Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ ## Indications for Use 510(k) Number (if known): Device Name: Navigator Anesthesia Delivery System Indications For Use: The Navigator Anesthesia Delivery System is a device used to administer to a patient, continuously or intermittently, a general inhalation anesthetic and to maintain a patient's ventilation. The Navigator is intended for use by licensed clinicians, for patients requiring anesthesia within a health care facility, and can be used in both adult and pediatric populations. Prescription Use (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Mi Khul (Division Sign-Off) Division of Anesthesiology, General Hospital Infection Control, Dental Devices Page 1 of K080 175 510(k) Number:
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...