QUANTIX/OR DEVICE

K030357 · Cardiosonix, Ltd. · DPW · Aug 20, 2003 · Cardiovascular

Device Facts

Record IDK030357
Device NameQUANTIX/OR DEVICE
ApplicantCardiosonix, Ltd.
Product CodeDPW · Cardiovascular
Decision DateAug 20, 2003
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 870.2100
Device ClassClass 2

Intended Use

The Quantix/OR device is intended for intra-operative examinations of blood flow measurements. Diagnostic blood flow measurements. For direct application to exposed blood vessel (miniature, sterilizable transducer).

Device Story

Quantix/OR is a dual-beam, angle-independent, pulse-wave Doppler ultrasound system; used intra-operatively by clinicians for direct application to exposed blood vessels. Device inputs ultrasound Doppler signals; transforms signals by deriving flow velocity from Doppler shift frequency; calculates volume blood flow by multiplying velocity by vessel cross-sectional area. Produces real-time measurements of blood flow velocity and volume blood flow. Output displayed to healthcare provider to assist in intra-operative hemodynamic assessment and clinical decision-making regarding vascular flow status.

Clinical Evidence

Bench testing only.

Technological Characteristics

Dual-beam, angle-independent, pulse-wave Doppler ultrasound system. Includes miniature, sterilizable transducers (Models CSN 01095, CSN 01094). Operates via Doppler shift frequency analysis to derive velocity and volume flow. Standalone system.

Indications for Use

Indicated for intra-operative diagnostic blood flow measurements in patients requiring direct application to exposed blood vessels.

Regulatory Classification

Identification

A cardiovascular blood flowmeter is a device that is connected to a flow transducer that energizes the transducer and processes and displays the blood flow signal.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ # SECTION 6 - SUMMARY OF SAFETY AND EFFECTIVENESS K030357 (Premarket Notification [510(k)] Number) #### 1. Applicant Cardiosonix Ltd. 3 Hatedhar Str. P.O.B. 3035. Raa'nana 43654 ISRAEL Tel: +972-9-7766444 Fax: +972-9-7766445 Corresponding Official: Name: Ahava M. Stein, Consultant Address: A. Stein - Regulatory Affairs Consulting Beit Hapa'amon (Box 124) 20 Hata'as St. 44425 Kfar Saba ISRAEL Tel: +972-9-767 0002 Fax: +972-9-766 8534 2. Device Name Device trade or proprietary name: Quantix/OR device Blood Flowmeter Common Name: Classification Name: Cardiovascular Blood Flowmeter, Class II, 870.2100 ## 3. Predicate Devices The Quantix/OR device is substantially equivalent to the following device: | Device | Manufacturer | 510(k) No. | |-----------|--------------------------------|------------| | FlowGuard | Biosonix Ltd./Cardiosonix Ltd. | K013803 | {1}------------------------------------------------ #### 4. Intended Use The Quantix/OR device is intended for intra-operative examinations of blood flow measurements. #### 5. Description of the Device The Quantix/OR is a dual-beam, angle-independent, pulse-wave Doppler ultrasound system used for intra-operative volume blood flow measurements, including blood flow velocity and volume blood flow. In addition to the conventional Doppler (blood flow velocity) measurements, the Quantix/OR technology utilizes special applications of ultrasound Doppler methods to obtain real-time measurements according to the definition of volume blood flow in target blood vessels. By definition, blood flow is the product of velocity and cross-sectional area. In other words, the volume blood flow is calculated by deriving flow velocity from the Doppler shift frequency using the basic standard formula and then multiplying the velocity by the cross-section area of the blood vessel.. #### 6. Technological Characteristics Compared to Predicate Device The technological characteristics, e.g., overall design, materials, mechanism of action, mode of operation, performance characteristics, etc., and the intended use of the Quantix/OR device are substantially equivalent to the predicate devices cited above. Signature General Manager, Dr. Danny Manor Jan. 27, 2003 Date Date {2}------------------------------------------------ Public Health Service Image /page/2/Picture/2 description: The image is a black and white seal. The seal is circular and contains an image of an eagle. The words "Department of Health & Human Services USA" are written around the edge of the seal. AUG 2 0 2003 Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 Cardiosonix Ltd. c/o Ms. Ahava Stein Regulatory Affairs Consultant Beit Hapa'amon (Box 124) 20 Hata'as Street. 44425 Kfar Saba ISRAEL Re: K030357 Quantix/OR Regulation Number: 21 CFR 870.2100 Regulation Name: Cardiovascular Blood Flowmeter Regulatory Class: Class II (two) Product Code: 74 DPW Dated: June 22, 2003 Received: June 26, 2003 Dear Ms. Stein: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. This determination of substantial equivalence applies to the following transducers intended for use with the Bi-Directional Doppler Volume Flowmeter, as described in your premarket notification: > Model CSN 01095 Model CSN 01094 {3}------------------------------------------------ ### Page 2 - Ms. Ahava Stein If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA mav publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus permits your device to proceed to market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801, please contact the Office of Compliance at (301) 594-4591. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or at (301) 443-6597 or at its Internet address "http://www.fda.gov/cdrh/dsmamain.html". If you have any questions regarding the content of this letter, please contact Kachi Enyinna at (301) 443-8262. Sincerely yours, Nolatter Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosures {4}------------------------------------------------ # Indications for Use Form Fill out one form for each ultrasound system and each transducer. | Mode of Operation | | | | | | | | | | | |----------------------------------|---|---|---|-----|-----|------------------|---------------------------------|------------------------------|-----------------------|--------------------| | Clinical<br>Application | A | B | C | PWD | CWD | Color<br>Doppler | Power<br>(Amplitude)<br>Doppler | Color<br>Velocity<br>Imaging | Combined<br>(Specify) | Other<br>(Specify) | | Ophthalmic | | | | | | | | | | | | Fetal | | | | | | | | | | | | Abdominal | | | | | | | | | | | | Intra-operative<br>(Specify) | | | | X | | | | | | | | Pediatric | | | | | | | | | | | | Small Organ<br>(Specify) | | | | | | | | | | | | Neonatal | | | | | | | | | | | | Cephalic | | | | | | | | | | | | Adult Cephalic | | | | | | | | | | | | Cardiac | | | | | | | | | | | | Trans-esophageal | | | | | | | | | | | | Trans-Rectal | | | | | | | | | | | | Trans-Vaginal | | | | | | | | | | | | Trans-Urethral | | | | | | | | | | | | Intra-Luminal | | | | | | | | | | | | Peripheral<br>Vascular | | | | | | | | | | | | Laparoscopic | | | | | | | | | | | | Musculo-Skeletal<br>Conventional | | | | | | | | | | | | Muscolo-Skeletal<br>Superficial | | | | | | | | | | | | Other (Specify) | | | | | | | | | | | Intended Use: Diagnostic blood flow measurements # Additional Comments: Intra-operative (Specify): For direct application to exposed blood vessel (miniature, sterilizable transducer) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Prescription Use (Per 21 CFR 801.109) Indications for Use Form Fill out one form for each ultrasound system and each transducer. (Division Sign-Off) Division of Cardiovascular Devices 510(k) Number K030357
Innolitics
510(k) Summary
Decision Summary
Classification Order
Enter a record ID and click Load to view the document.
100%