K021471 · Marquette Medical, Inc. · FPA · Sep 8, 2003 · General Hospital
Device Facts
Record ID
K021471
Device Name
MARQUETTE HUBER TRAP SAFETY INFUSION SET
Applicant
Marquette Medical, Inc.
Product Code
FPA · General Hospital
Decision Date
Sep 8, 2003
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 880.5440
Device Class
Class 2
Attributes
Therapeutic
Intended Use
The Marquette Medical Safety Huber Infusion Set is a safety IV administration set used to access surgically implanted vascular ports. The Medical Safety Huber Needle is used to administer fluids or drugs and blood sampling. The Marquette Medical Safety Huber Infusion Set facilitates safe removal of the needle by encapsulating the needle within a telescoping plastic cone to help prevent needlestick injuries when using the device for vascular port access.
Device Story
Safety IV administration set for accessing surgically implanted vascular ports; facilitates fluid/drug administration and blood sampling. Features telescoping plastic cone mechanism to encapsulate needle upon removal; designed to prevent needlestick injuries. Used by clinicians in clinical settings for vascular port access.
Clinical Evidence
No clinical data provided; bench testing only.
Technological Characteristics
Safety IV administration set; includes Huber needle and telescoping plastic cone mechanism for needle encapsulation. Class II device; Product Codes FPA, LJT.
Indications for Use
Indicated for patients requiring access to surgically implanted vascular ports for the administration of fluids, drugs, or blood sampling.
Regulatory Classification
Identification
An intravascular administration set is a device used to administer fluids from a container to a patient's vascular system through a needle or catheter inserted into a vein. The device may include the needle or catheter, tubing, a flow regulator, a drip chamber, an infusion line filter, an I.V. set stopcock, fluid delivery tubing, connectors between parts of the set, a side tube with a cap to serve as an injection site, and a hollow spike to penetrate and connect the tubing to an I.V. bag or other infusion fluid container.
Special Controls
*Classification.* Class II (special controls). The special control for pharmacy compounding systems within this classification is the FDA guidance document entitled “Class II Special Controls Guidance Document: Pharmacy Compounding Systems; Final Guidance for Industry and FDA Reviewers.” Pharmacy compounding systems classified within the intravascular administration set are exempt from the premarket notification procedures in subpart E of this part and subject to the limitations in § 880.9.
Related Devices
K170881 — ISP Safety Huber Needle Infusion Set · Infusion Safety Products, Inc. · Dec 14, 2017
K051009 — HUBER CLEAR SAFETY INFUSION SET · Now Medical Distribution, Inc. · Jul 12, 2005
K042234 — MODIFICATION TO: LIFTLOC SAFTEY INFUSION SET · Specialty Health Products, Inc. · Sep 8, 2004
K081210 — NIPRO SAFETOUCH HUBER INFUSTION SET · Nipro Medical Corp. · Oct 21, 2008
K142590 — All Safe Huber Safety Infusion Set · Nexus Medical, LLC · Jan 16, 2015
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image is a black and white circular seal. The seal contains the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the border of the circle. Inside the circle is a stylized image of an eagle or other bird with three wing-like shapes extending from its body.
Public Health Service
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
SEP - 8 2003
Marquette Medical, Incorporated C/O Mr. E.J. Smith Smith & Associates P.O. Box 4341 Crofton, Maryland 21114
Re: K021471
Trade/Device Name: Marquette Huber Trap Safety Infusion Set Huber Needle Regulation Number: 880.5440, 880.5965 Regulation Name: Intravascular Administration Set Subcutaneous, Implanted Intravascular Infusion Port and Catheter Regulatory Class: II Product Code: FPA, LJT Dated: July 25, 2003 Received: July 28, 2003
Dear Mr. Smith:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{1}------------------------------------------------
Page 2 - Mr. Smith
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4618. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours.
Susan Runner, DDS, MA
Runner, DDS. N Susan Interim Director Division of Anesthesiology, General Hospital Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
510(k) Number:
Device Name:
Classification Panel:
Indications for Use:
The Marquette Medical Safety Huber Infusion Set is a safety IV administration set used to access surgically implanted vascular ports. The Medical Safety Huber Needle is used to administer fluids or drugs and blood sampling. The Marquette Medical Safety Huber Infusion Set facilitates safe removal of the needle by encapsulating the needle within a telescoping plastic cone to help prevent needlestick injuries when using the device for vascular port access.
Palture Cucenite
(Division Sign-Off) Division of Anesthesiology, General Hospital, Infection Control, Dental Devices
510(k) Number:________________________________________________________________________________________________________________________________________________________________
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use:
Over-the-Counter Use: --------------------------------------------------------------------------------------------------------------------------------------------------------
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.