← Product Code [DLJ](/submissions/TX/subpart-d%E2%80%94clinical-toxicology-test-systems/DLJ) · K061503

# DIMENSION CYCLOSPORINE EXTENDED RANGE CALIBRATOR (DC108A) (K061503)

_Dade Behring, Inc. · DLJ · Jun 22, 2006 · Clinical Toxicology · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/TX/subpart-d%E2%80%94clinical-toxicology-test-systems/DLJ/K061503

## Device Facts

- **Applicant:** Dade Behring, Inc.
- **Product Code:** [DLJ](/submissions/TX/subpart-d%E2%80%94clinical-toxicology-test-systems/DLJ.md)
- **Decision Date:** Jun 22, 2006
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 862.3200
- **Device Class:** Class 2
- **Review Panel:** Clinical Toxicology

## Indications for Use

The Dimension® CSAE Cyclosporine Extended Range Calibrator is an in vitro diagnostic product intended to be used to calibrate the CSAE Cyclosporine Extended range method for the Dimension® clinical chemistry system and the Syva® Emit® 2000 Cyclosporine assay.

## Device Story

The Dimension® CSAE Cyclosporine Extended Range Calibrator is a set of six vials containing cyclosporine in preserved whole blood hemolysate. It provides five calibration levels (200, 400, 800, 1400, 2000 ng/mL) and one diluent (0.0 ng/mL) for over-range sample dilution. The device is used in clinical laboratory settings to calibrate the CSAE Cyclosporine Extended range method on Dimension clinical chemistry systems and the Syva® Emit® 2000 Cyclosporine assay. By establishing a reference curve, the calibrator enables the clinical chemistry system to accurately quantify cyclosporine concentrations in patient samples, assisting healthcare providers in monitoring therapeutic drug levels.

## Clinical Evidence

No clinical data. Bench testing only. Stability testing performed over 12 months comparing storage at -15 to -25°C versus -70°C reference. Traceability established via LC/MS/MS value assignment of reference lots.

## Technological Characteristics

Preserved whole blood hemolysate matrix; six-level kit (0-2000 ng/mL); frozen storage (-15 to -25°C). Traceability to LC/MS/MS reference lot. Standards: GP22-A, CEN 13640, ISO 14971:2000, ISO 15223.

## Regulatory Identification

A clinical toxicology calibrator is a device intended for medical purposes for use in a test system to establish points of reference that are used in the determination of values in the measurement of substances in human specimens. A clinical toxicology calibrator can be a mixture of drugs or a specific material for a particular drug (e.g., ethanol, lidocaine, etc.). (See also § 862.2 in this part.)

## Special Controls

*Classification.* Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9.

## Predicate Devices

- Dimension® CSAE Cyclosporine Extended Range Calibrator (DC108) ([K052015](/device/K052015.md), [K053108](/device/K053108.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

1

# 510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY ASSAY ONLY TEMPLATE

A. 510(k) Number:
k061503

B. Purpose for Submission:
Modification of an existing product

C. Measurand:
Cyclosporine

D. Type of Test:
Calibrator

E. Applicant:
Dade Behring, Inc.

F. Proprietary and Established Names:
Dimension® Extended Range Cyclosporine Calibrator (DC108A)

G. Regulatory Information:

|  Product Code | Classification | Regulation Section | Panel  |
| --- | --- | --- | --- |
|  DLJ, Calibrators, Drug specific | Class II | 21 CFR §862.3200
Clinical Toxicology
Calibrator | Toxicology  |

H. Intended Use:

1. Intended use(s):
See below.

2. Indication(s) for use:
The Dimension® CSAE Cyclosporine Extended Range Calibrator is an in vitro

{1}

diagnostic product intended to be used to calibrate the CSAE Cyclosporine Extended range method for the Dimension® clinical chemistry system and the Syva® Emit® 2000 Cyclosporine assay.

3. Special conditions for use statement(s):

None

4. Special instrument requirements:

Not applicable to a calibrator

I. Device Description:

The Dimension® CSAE Cyclosporine Extended Range Calibrator contains cyclosporine in a preserved whole blood hemolysate. The kit consists of 2 sets of the following: one glass vial of sample diluent (0.0 ng/ml of cyclosporine) and one glass vial of levels 1 through 5. Target concentrations for the five calibrator levels are approximately 200, 400, 800, 1400 and 2000 ng/ml of cyclosporine. Level 0 is included for dilution of over-range samples (&gt;2000 ng/mL) in order to obtain results within the assay range; it is not used in calibration. Levels 1 thru 5 are used for calibration of the CSAE method.

Human Source Material was tested by FDA approved methods for the presence of antibodies to Human Immunodeficiency Virus Type 1 (HIV-1) and Type 2 (HIV-2), as well as for Hepatitis B Surface Antigen and antibody to Hepatitis C Virus (HCV), and found to be negative (not repeatedly reactive.)

A. Substantial Equivalence Information:

Predicate device name(s):

Dimension Cyclosporine Extended Range Calibrator (DC108)

Predicate K number(s):

k052015, k053108

Comparison with predicate:

The Dimension CSAE Cyclosporine Extended Range Calibrator (DC108A) is identical to the predicate in the following ways: intended use, matrix, and target concentrations of calibrators. This device is different to the predicate in the following ways:

2

{2}

|  Differences  |   |   |
| --- | --- | --- |
|  Item | Device | Predicate  |
|  Traceability | Reference lot stock solution prepared gravimetrically. Final reference lot sent out for LC/MS/MS assignment. | Reference lot stock solution tested by LC/MS/MS internally then formulated. Final reference lot sent out for LC/MS/MS assignment.  |
|  Value Assignment of new calibrator lot | Stock solution for new calibrator formulated using standard gravimetric procedures prior to formulation. | Stock solution for new calibrator formulated using standard gravimetric procedures and tested by LC/MS/MS prior to formulation.  |
|  Production site | Calibrator manufactured by Dade Behring Inc. in Glasgow Delaware. | Calibrator prepared by an OEM Manufacturer for Dade Behring Inc.  |
|  Packaging | Glass vials. | Plastic vials.  |
|  Storage temperature | Unopened storage temperature is -15 to -25°C. | Unopened storage temperature is -17 to -27°C.  |

## K. Standard/Guidance Document Referenced (if applicable):

|  STANDARDS  |
| --- |
|  Title and Reference Number  |
|  Medical Devices - Symbols to be used with medical device labels, labeling and information to be supplied (15223)  |
|  Medical devices - Application of risk management to medical devices (14971:2000)  |
|  Stability Testing of In Vitro Diagnostic Reagents (13640)  |
|  Continuous Quality Improvement: Essential Management Approaches; Approved Guideline (GP 22-A)  |

{3}

4

|  GUIDANCE  |   |   |   |
| --- | --- | --- | --- |
|  Document Title | Office | Division | Web Page  |
|  Guidance for Industry and FDA Staff - Use of Symbols on Labels and in Labeling of In Vitro Diagnostic Devices Intended for Professional Use |  |  | http://www.fda.gov/cdrh/ocd/guidance/4444.html  |
|  Class II Special Controls Guidance Document: Cyclosporine and Tacrolimus Assays; Guidance for Industry and FDA | OIVD | DCTD | http://www.fda.gov/cdrh/ode/guidance/1380.html  |

L. Test Principle:

Not applicable.

M. Performance Characteristics (if/when applicable):

1. Analytical performance:

a. Precision/Reproducibility:

Not applicable.

b. Linearity/assay reportable range:

Not applicable.

c. Traceability, Stability, Expected values (controls, calibrators, or methods):

Stability:

Target shelf life for the Dimension® CSAE Calibrator (DC108A) is 12 months. Calibrator shelf life is determined by comparing results of the product stored at -15 to -25°C (recommended storage temperature) with product stored at -70°C (reference storage temperature) to ensure that analytical system drift is dissociated with calibrator drift. Three lots of product were tested on days 0, 7, 14, 30, 90, 120, 150, 180, 210, 240, 270, 300, 330, 360, 390.

Traceability:

Commercially available CSA powder is used to formulate a reference stock solution. A reference lot is formulated by diluting the stock into whole blood hemolysate with preservatives at six different levels and stored -70°C. The reference lot value is assigned by LC/MS/MS.

{4}

Value Assignment:

A cyclosporine stock solution is prepared using standard gravimetric procedure. Aliquots of the stock solution are added to measured amounts of calibrator matrix to yield the desired concentration for each calibrator level. Cyclosporine calibrators are prepared in preserved whole blood hemolysate. The recovery of the six levels are verified versus a control calibrator lot (control calibrator = any approved calibrator lot) and versus the frozen reference lot.

d. Detection limit:
Not applicable.

e. Analytical specificity:
Not applicable.

f. Assay cut-off:
Not applicable.

2. Comparison studies:
a. Method comparison with predicate device:
Not applicable.
b. Matrix comparison:
Not applicable.

3. Clinical studies:
a. Clinical Sensitivity:
Not applicable.
b. Clinical specificity:
Not applicable.
c. Other clinical supportive data (when a. and b. are not applicable):
Not applicable.

5

{5}

4. Clinical cut-off:
Not applicable.

5. Expected values/Reference range:
Not applicable.

N. Proposed Labeling:
The labeling is sufficient and it satisfies the requirements of 21 CFR Part 809.10.

O. Conclusion:
The submitted information in this premarket notification is complete and supports a substantial equivalence decision.

6

---

**Source:** [https://fda.innolitics.com/submissions/TX/subpart-d%E2%80%94clinical-toxicology-test-systems/DLJ/K061503](https://fda.innolitics.com/submissions/TX/subpart-d%E2%80%94clinical-toxicology-test-systems/DLJ/K061503)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
