ADVIA CHEMISTRY DRUG CALIBRATOR II, MODEL 10376771

K090900 · Siemens Healthcare Diagnostics · DKB · Jun 1, 2009 · Clinical Toxicology

Device Facts

Record IDK090900
Device NameADVIA CHEMISTRY DRUG CALIBRATOR II, MODEL 10376771
ApplicantSiemens Healthcare Diagnostics
Product CodeDKB · Clinical Toxicology
Decision DateJun 1, 2009
DecisionSESE
Submission TypeAbbreviated
Regulation21 CFR 862.3200
Device ClassClass 2

Intended Use

The ADVIA Chemistry TDM DRUG Calibrator II is for in vitro diagnostic use in the calibration of Carbamazepine_2 (CARB_2), Gentamicin_2 (GENT_2), Tobramycin_2 (TOBR_2), Valproic Acid_2 (VPA_2), and Vancomycin_2 (VANC_2) methods on the ADVIA Chemistry Systems. For prescription use only.

Device Story

ADVIA Chemistry TDM DRUG Calibrator II is a multi-analyte, liquid, bovine serum-based product; supplied as a kit with 5 levels of calibrators (5.0 mL per vial). Used for calibration of specific drug assays on ADVIA Clinical Chemistry Systems. Calibrator values are assigned using an ADVIA system calibrated with an internal Anchor Calibrator, which is traceable to USP material. Product is intended for professional use in clinical laboratory settings to ensure accurate quantification of therapeutic drugs in patient samples.

Clinical Evidence

No clinical data. Bench testing only. Stability established via real-time data (12 months unopened, 30 days open). Traceability established via internal Anchor Calibrator linked to USP material.

Technological Characteristics

Multi-analyte liquid calibrator; bovine serum matrix; 5 levels; 5.0 mL vials. Traceable to USP material. Stability: 12 months at 4°C (unopened), 30 days at 2-8°C (opened).

Indications for Use

Indicated for in vitro diagnostic calibration of Carbamazepine, Gentamicin, Tobramycin, Valproic Acid, and Vancomycin assays on ADVIA Chemistry Systems. No specific patient population or contraindications defined.

Regulatory Classification

Identification

A clinical toxicology calibrator is a device intended for medical purposes for use in a test system to establish points of reference that are used in the determination of values in the measurement of substances in human specimens. A clinical toxicology calibrator can be a mixture of drugs or a specific material for a particular drug (e.g., ethanol, lidocaine, etc.). (See also § 862.2 in this part.)

Special Controls

*Classification.* Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ ## 510(k) Summary of Safety and Effectiveness for the ## ADVIA® Chemistry DRUG Calibrator II This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of SMDA 1990 and 21 CFR 807.92. A. 510(k) Number: K090900 B. Date of Preparation: December 22, 2008 ### C. Proprietary and Established Names: ADVIA® Chemistry DRUG Calibrator II ## D. Applicant: Siemens Healthcare Diagnostics Inc., 511 Benedict Ave, Tarrytown, NY 10591 Kira Gordon. Sr. Regulatory Affairs Specialist Fax: (914) 524-2500 Office: (914) 524-2996 ## E. Regulatory Information: ADVIA Chemistry DRUG Calibrator II 1. Regulation section: 21 CFR § 862.3200 Clinical Toxicology Calibrator. 2. Classification: Class II 3. Product Code: DKB, calibrators, drug mixture 4. Panel: Toxicology ### F. Predicate Device: ADVIA Chemistry TDM DRUG Calibrator II is substantially equivalent to the (formerly) Dade Behring Dimension Drug Calibrator II (DRUG CAL II - DC49D) cleared under K033809. ## G. Device Description: ADVIA Chemistry TDM DRUG Calibrator II is a multi-analyte, liquid, bovine serum based product containing multiple analytes. The kit consists of 2 vials of each of 5 calibrator levels which are ready for use (no preparation is required). The volume per {1}------------------------------------------------ vial is 5.0 mL. Tobramycin, Carbamazepine, Valproic Acic, Vancomycin and Gentamicin analytes are value assigned for ADVIA Chemsitry systems. ## H. Intended Use: The ADVIA Chemistry TDM DRUG Calibrator II is for in vitro diagnostic use in the calibration of Carbamazepine 2 (CARB 2), Gentamicin 2 (GENT 2), Tobramycin_2 (TOBR_2), Valproic Acid_2 (VPA_2), and Vancomycin_2 (VANC_2) methods on the ADVIA Chemistry Systems ## I. Substantial Equivalence Information: The ADVIA Chemistry TDM Drug Calibrator II and Dimension Drug Calibrator II were compared in the following table. | Item | New Device - The ADVIA<br>Chemistry TDM Drug II Calibrator | Predicate Device - (formerly) Dade<br>Behring Dimension Drug Calibrator II<br>(DC49D) | |------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Intended Use | For in vitro diagnostic use in the<br>calibration of Carbamazapine_2<br>(CARB_2), Gentamicin_2<br>(GENT_2), Tobramycin_2 (TOB_2),<br>Valproic Acid_2 (VPA_2), and<br>Vancomycin_2 (VANC_2) methods<br>on the ADVIA Chemistry<br>systems. | DRUG CAL II is an in vitro diagnostic<br>product for the calibration of the<br>following methods packaged in the<br>Flex reagent cartridges: acetaminophen<br>(ACTM), carbamazepine (CRBM),<br>digitoxin (DGTX), gentamicin<br>(GENT), lidocaine (LIDO), N-<br>acetylprocainamide (NAPA),<br>procainamide (PROC), tobramycin<br>(TOBR), valproic acid (VALP), and<br>vancomycin (VANC). | | Formulation /<br>analytes present | carbamazepine, gentamicin,<br>tobramycin, valproic acid,<br>vancomycin | acetaminophen, carbamazepine,<br>digitoxin, gentamicin, lidocaine, N-<br>acetylprocainamide, procainamide,<br>tobramycin, valproic acid, and<br>vancomycin | | Measured<br>Analytes (value<br>assigned) | Carbamazepine (CARB_2),<br>Gentamicin (GENT_2), Tobramycin<br>(TOBR_2), Valproic Acid_2<br>(VPA_2), Vancomycin (VANC_2) | acetaminophen (ACTM),<br>carbamazepine (CRBM), digitoxin<br>(DGTX), gentamicin (GENT),<br>lidocaine (LIDO), N-<br>acetylprocainamide (NAPA),<br>procainamide (PROC), tobramycin<br>(TOBR), valproic acid (VALP), and<br>vancomycin (VANC). | | Form | Liquid | Liquid | | Traceability | USP | USP | | Matrix | Bovine | Bovine | | Number of<br>Levels | five | five | | Packaging | Ten vials: two vials at five levels (5.0<br>mL each) | Ten vials: two vials at five levels (5.0<br>mL each) | {2}------------------------------------------------ | Stability | 12 months - shelf-life<br>30 days open vial | 12 months - shelf-life<br>30 days open vial | |-----------|---------------------------------------------|---------------------------------------------| |-----------|---------------------------------------------|---------------------------------------------| ## J. Conclusion: The multianalyte, five level, bovine serum base ADVIA Chemistry TDM DRUG Calibrator II is substantially equivalent to the Dimension DRUG Calibrator II. They are identical in composition and both used in calibration of TDM on Chemistry systems. {3}------------------------------------------------ Image /page/3/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES.USA" around the perimeter. Inside the circle is an eagle with a caduceus, a symbol of medicine, entwined around its wing. ## DEPARTMENT OF HEALTH & HUMAN SERVICES Food and Drug Administration 2098 Gaither Road Rockville MD 20850 Siemens Healthcare Diagnostics, Inc. c/o Dr. Kira Gordon 511 Benedict Ave Tarrytown, NY 10591 JUN - 1 2009 Re: k090900 > Trade Name: ADVIA Chemistry DRUG Calibrator II Regulation Number: 21 CFR 862.3200 Regulation Name: Clinical toxicology calibrator Regulatory Class: Class II Product Codes: DKB Dated: March 31, 2009 Received: April 1, 2009 Dear Dr. Gordon: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA), You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in Title 21, Code of Federal Regulations (CFR), Parts 800 to 895. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801 and 809); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); and good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820). {4}------------------------------------------------ Paqe - 2 This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of In Vitro Diagnostic Device Evaluation and Safety at (240) 276-0450. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket Surveillance at (240) 276-3474. For questions regarding the reporting of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at (240) 276-3464. For more information regarding the reporting of adverse events, please go to http://www.fda.gov/cdrh/mdr/, You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours. \$\mathcal{A}\$ C.H. Courtney C. Harper, Ph.D. Acting Director Division of Chemistry and Toxicology Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health #### Enclosure {5}------------------------------------------------ # Indication for Use #### 510(k) Number (if known): k090900 . इन्द् ADVIA Chemistry DRUG Calibrator II Device Name: Indication For Use: The ADVIA Chemistry TDM DRUG Calibrator II is for in vitro diagnostic use in the calibration of Carbamazepine 2 (CARB_2), Gentamicin_2 (GENT_2), Tobramycin_2 (TOBR 2), Valproic Acid 2 (VPA 2), and Vancomycin 2 (VANC 2) methods on the ADVIA Chemistry Systems. Prescription Use X (21 CFR Part 801 Subpart D) And/Or Over the Counter Use (21 CFR Part 801 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE; CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of In Vitro Diagnostic Device Evaluation and Safety (OIVD) Keeley Erff Division Sign-Off Office of In Vitro Diagnostic Device Evaluation and Safety 510(k) k090900
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...