ACRY ISLAND BORDER DRESSING, MODELS 2031, 2032, 2033

K992032 · Acrymed, Inc. · KMF · Aug 19, 1999 · General Hospital

Device Facts

Record IDK992032
Device NameACRY ISLAND BORDER DRESSING, MODELS 2031, 2032, 2033
ApplicantAcrymed, Inc.
Product CodeKMF · General Hospital
Decision DateAug 19, 1999
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 880.5090
Device ClassClass 1
AttributesTherapeutic

Indications for Use

AcryDerm Island Border Dressing is intended for use as an external wound dressing for the management of wound expensive from acute and chronic wounds. Typical acute wounds would included incision wounds, lacerations, donor site, minor burns skin tears and abrasions. Typical chronic would include pressure sores, diabetic ulcers, and venous and arterial stasis ulcers. AcryDerm Island Border Dressing is contraindicated for the treatment of third degree burns.

Device Story

AcryDerm Island Border Dressing is a composite, single-use, sterile wound dressing. It consists of a central absorbent polyacrylate hydrogel matrix (AcryDerm Advanced Wound Dressing) mounted on a medical-grade polyurethane transparent thin film adhesive backing. The device is applied externally to wounds by clinicians or patients. The hydrogel matrix absorbs wound exudate and transpires excess moisture as vapor through the polyurethane film; it also donates moisture to dry wound substrates. The dressing is supplied sterile via E-beam radiation in individual pouches. It functions as a protective cover to manage moisture balance in acute and chronic wounds, aiding in wound management.

Clinical Evidence

Bench testing only. Laboratory tests demonstrated the hydrogel matrix absorbs in excess of 7 times its weight in moisture and the polyurethane film provides a high moisture vapor transmission rate. Testing confirmed the construct absorbs excess moisture and donates moisture to dry substrates.

Technological Characteristics

Multi-layered construction: semi-rigid PET casting sheet, adhesive polyurethane transparent thin film, polyacrylate hydrogel matrix island, and PE release liners. Sensing/actuation: passive moisture absorption and vapor transpiration. Energy source: none. Connectivity: none. Sterilization: E-beam radiation. Form factor: composite island dressing.

Indications for Use

Indicated for management of acute wounds (incision wounds, lacerations, donor sites, minor burns, skin tears, abrasions) and chronic wounds (pressure sores, diabetic ulcers, venous/arterial stasis ulcers). Contraindicated for third-degree burns. Suitable for OTC and prescription use.

Regulatory Classification

Identification

A liquid bandage is a sterile device that is a liquid, semiliquid, or powder and liquid combination used to cover an opening in the skin or as a dressing for burns. The device is also used as a topical skin protectant.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ ACRYMED K992032 AUG 19 1995 ## Summary of Safety and Effectiveness | Contact Person: | Dr. Bruce L. Gibbins, Chairman & Chief Technical Officer | |----------------------------|-------------------------------------------------------------------------------------| | Date of preparation: | June 11, 1999 | | Device Name (proprietary): | AcryDerm® Island Border Dressing | | Common Name: | Moist wound island border dressing | | Classification Name: | Hydrophilic wound dressing | | Classification: | Unclassified; as recommended by the General and Plastic<br>Surgery Devices Panel 79 | Legally marketed device(s) for substantial equivalence comparison: AcryDerm® Advanced Wound Dressing, (AcryMed, Inc.) Clearsite 1 Bordered Dressing, (New Dimension Medicine (NDM), Inc.) Uni-Site The Breathable Transparent Dressing (TTL Medical) Description of Device: AcryDerm Island Border Dressing is a composite thin film adhesive backed moist hydrophilic wound dressing. The composite dressing has an island of polyacrylate AcryDerm Advanced Wound Dressing matrix centrally placed on the adhesive side of a medical grade polyurethane transparent thin film. The composite product is a moist wound dressing for external use. AcryDerm Island Border Dressing will be supplied sterile (E-beam radiation), in single use individual primary heat seated pouches, packed in dispenser boxes along with an appropriate insert of instructions for use. Biocompatibility: An assessment of the biocompatibility issues has been established according to Part-1 of the ISO standard (Biological Evaluation of Medical Devices). Intended Use of the Device: AcryDerm Island Border Dressing is intended for use as an external wound dressing for the management of wound expensive from acute and chronic wounds. Typical acute wounds would included incision wounds, lacerations, donor site, minor burns skin tears and abrasions. Typical chronic would include pressure sores, diabetic ﺰ ulcers, and venous and arterial stasis ulcers. AcryDerm Island Border Dressing is contraindicated for the treatment of third degree burns. Technological Characteristics: The AcryDerm Island Border Dressing is a multi-layered construction. Sequentially the components are a semi-rigid disposable PET casting sheet, an adhesive polyurethane transparent thin film identical to that used in Uni-Site Breathable Transparent Dressing (predicate product), AcryDerm Advanced Wound Dressing (predicate product) matrix island, and disposable PE release liners. The wound contact matrix, when placed against the wound, absorbs exudate and transpires excess moisture, as vapor, through the matrix and polyurethane film. This construction is substantially similar to that used in Clearsite Bordered Dressing (predicate product). The classification, intended uses, composition, and methods of manufacturing of AcryDerm Island Border Dressing are substantially equivalent to the predicate devices. Performance Characteristics: The island component of the dressing is an absorbent hydrogel matrix that absorbs in excess of 7 times its weight in moisture. The polyurethane thin film is a high moisture vapor transmission rate transparent cover dressing. Their combination as a composite construct is done to make a single use wound management product. Laboratory tests have shown that this construct absorbs in the presence of excess moisture and donates moisture when in contact with a dry substrate. This product has utility in the management of exudate, Manufacturing: AcryDerm Island Border Dressing will be manufactured according to the product specifications and under good manufacturing practices that ensure the device is safe and effective for its intended use. {1}------------------------------------------------ Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular emblem with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the top half of the circle. Inside the circle is a stylized image of an eagle or bird-like figure with three curved lines representing its wings or feathers. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 AUG 1 9 1999 Bruce Gibbins, Ph.D. Chairman & Chief Technical Officer AcryMed, Inc. 12232 SW Garden Place Portland, Oregon 97223 K992032 Re: Trade Name: AcryDerm Island Border Dressing Regulatory Class: Unclassified Product Code: KMF Dated: June 11, 1999 Received: June 16, 1999 Dear Dr. Gibbins: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (OS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. {2}------------------------------------------------ ## Page 2 - Bruce Gibbins, Ph.D. This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4595. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html". Sincerely yours, Neil R P Ogden for Colin M. Willis Ph.D., M.D. Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {3}------------------------------------------------ Page _of K992032 510(k) Number (if known): _ K992032 Device Name: AcryDerm Island Border Dressing Indications For Use: Cover dressing for the following wounds: Over the Counter uses include: - Lacerations . - Minor burns ﻠﺔ ﺍﻟ - Skin tears - Abrasions . Use prescribed by a healthcare professional include: - Pressure sores � - Diabetic ulcers . < ... Incision wounds "> - Donor site wounds ● - Venous stasis ulcers t - Arterial stasis ulcers ● Contra-Indications: - Not indicated for the treatment of third degree burns ● (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) | (Division Sign-Off) | | |-----------------------------------------|----------| | Division of General Restorative Devices | K 992032 | | 510(k) Number | | | Prescription Use (Per 21 CFR 801.109) | X | |-----------------------------------------------|---| | Over-The-Counter Use (Optional Format 1-2-96) | X | AcryDerm Island Border Dressing Pre-market Notification 510(k)
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...