# OSMOCYTE ULTRA/PE PILLOW WOUND DRESSING (K962623)

_Procyte Corp. · KMF · Nov 26, 1996 · General Hospital · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/SU/subpart-f%E2%80%94general-hospital-and-personal-use-therapeutic-devices/KMF/K962623

## Device Facts

- **Applicant:** Procyte Corp.
- **Product Code:** [KMF](/submissions/HO/subpart-f%E2%80%94general-hospital-and-personal-use-therapeutic-devices/KMF.md)
- **Decision Date:** Nov 26, 1996
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 880.5090
- **Device Class:** Class 1
- **Review Panel:** General Hospital
- **Attributes:** Therapeutic

## Indications for Use

An absorptive pillow dressing for the management of exudating wounds, infected and non-infected, including pressure ulcers, diabetic ulcers, venous stasis ulcers, arterial ulcers, 1st and 2nd degree burns, donor sites, postoperative incisions, other bleeding surface wounds, dermal lesions, trauma injuries or incisions.

## Device Story

OsmoCyte Ultra/PE Pillow Wound Dressing is a passive wound dressing designed for exudating wounds. It consists of highly absorptive hydrophilic polymer granules encased in an inert low-density polyethylene (LDPE) mesh pillow. The mesh allows wound exudate to pass through for absorption by the granules while preventing granule migration into the wound bed. This design facilitates easy removal, particularly in deep cavity or tunnel wounds. The dressing is applied by a clinician or patient to the wound site to manage exudate and maintain a moist wound environment. It does not involve active electronic components, software, or algorithms.

## Clinical Evidence

Bench testing only. Biocompatibility testing was performed in accordance with ISO 10993-1 standards to support safe use on breached or compromised skin.

## Technological Characteristics

Absorptive pillow dressing; materials include hydrophilic polymer granules and inert low-density polyethylene (LDPE) mesh fabric. Passive device; no energy source or connectivity. Biocompatibility evaluated per ISO 10993-1.

## Regulatory Identification

A liquid bandage is a sterile device that is a liquid, semiliquid, or powder and liquid combination used to cover an opening in the skin or as a dressing for burns. The device is also used as a topical skin protectant.

## Predicate Devices

- HyQ Wound Dressing (Kingston Technologies)
- Allevyn Cavity Dressing (Smith + Nephew)
- Kaltostat Wound Packing (Calgon Vestal)
- Aquacel (Convatec)
- Sorbsan Topical Wound Dressing (Dow Hickam)

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

K962623

510(k) Number K962623
Summary
September 6, 1996

ATTACHMENT 8
NOV 26 1996

510(k) Summary

Submitter's Name and Address:
ProCyte Corporation
12040 115th Ave NE #210
Kirkland, Washington 98034-6900

Contact person and telephone number:
Paul Ketteridge
Regulatory Affairs Officer
Telephone: (206) 820-4548
Fax: (206) 820-7611

Date summary was prepared: September 4, 1996

Name of the Device:
Proprietary name: OsmoCyte™ Ultra/PE Pillow Wound Dressing
Common name: Wound Dressing
Classification name: Wound and Burn Dressing

Identification of Predicate Devices to which Substantial Equivalence is Being Claimed:
OsmoCyte™ Ultra/PE Pillow Wound Dressing is substantially equivalent in function and intended use to the following non-classified commercially available or 510(k) cleared non-interactive wound and burn dressings:

- HyQ Wound Dressing (Kingston Technologies)
- Allevyn Cavity Dressing (Smith + Nephew)
- Kaltostat Wound Packing (Calgon Vestal)
- Aquacel (Convatec)
- Sorbsan Topical Wound Dressing (Dow Hickam)

{1}

510(k) Number K962623

Summary

September 6, 1996

## Device Description:

**Explanation of how the device functions:** OsmoCyte™ Ultra/PE Pillow Wound Dressing utilizes the hydrophilic polymer granules contained in a mesh pillow to absorb many times their weight in wound exudate. Since the granules are contained in the mesh pillow, they are easily removed, thereby significantly reducing the possibility of retaining granules within the wound and allowing the OsmoCyte™ Ultra/PE Pillow Wound Dressing to be utilized in wounds with deep cavities or tunnels.

**Basic scientific concepts that form the basis for the device:** OsmoCyte™ Ultra/PE Pillow Wound Dressing contains a highly absorptive polymer able to absorb many times its weight in wound exudate.

**Significant physical and performance characteristics of the device such as device design, materials used, and physical properties:** OsmoCyte™ Ultra/PE Pillow Wound Dressing contains highly absorptive polymer granules able to absorb many times their weight in wound exudate. The granules are encased in an inert low density polyethylene mesh fabric which allow the wound exudate to pass through and be absorbed by the polymer granules but which contains the granules, thus allowing for the dressing's easy removal from cavity or tunnel wounds.

## Statement of the Intended Use of the Device, Including General Description of the Conditions the Device Will Mitigate and the Patient Population for which the Device Is Intended:

An absorptive pillow dressing for the management of exudating wounds, infected and non-infected, including pressure ulcers, diabetic ulcers, venous stasis ulcers, arterial ulcers, 1st and 2nd degree burns, donor sites, postoperative incisions, other bleeding surface wounds, dermal lesions, trauma injuries or incisions.

These indication statements are not different from the predicate devices identified above.

## Statement of how the Technological Characteristics of the Device Compare to those of the Predicate Device:

The technological characteristics of the device are similar to the predicate devices. The ability to absorb large amounts of wound exudate, coupled with the ability to be used safely in deep cavity or tunnel wounds is comparable to several the predicate devices. In addition, OsmoCyte™

{2}

510(k) Number K962623

Summary

September 6, 1996

Ultra/PE Pillow Wound Dressing has the advantage, by using an inert LDPE mesh, containing the absorbent granules, to assuring its complete removal from the wound.

## Assessment of Performance Data:

Biocompatibility testing has been performed as recommended in the "International Standard for the Biological Evaluation of Medical Devices, ISO 10993-1." These tests support the safe use of OsmoCyte™ Ultra/PE Pillow Wound Dressing as a wound dressing temporary in contact with breached or compromised skin.

---

**Source:** [https://fda.innolitics.com/submissions/SU/subpart-f%E2%80%94general-hospital-and-personal-use-therapeutic-devices/KMF/K962623](https://fda.innolitics.com/submissions/SU/subpart-f%E2%80%94general-hospital-and-personal-use-therapeutic-devices/KMF/K962623)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com