BIPOLAR SUCTION COAGULATOR
Device Facts
| Record ID | K965241 |
|---|---|
| Device Name | BIPOLAR SUCTION COAGULATOR |
| Applicant | Kirwan Surgical Products, Inc. |
| Product Code | GEI · General, Plastic Surgery |
| Decision Date | Feb 28, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 878.4400 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Intended Use
The Bipolar Suction Coagulator (Angled) is a disposable device, designed to be used in soft tissue surgical procedures that require slow to rapid fluid evacuation and low energy output for the coagulation of the tissue i.e., neurosurgery, endoscopic, sinusoidial, ENT, OB-GYN and plastic surgery.
Device Story
Disposable bipolar suction coagulator; used in soft tissue surgery (neurosurgery, ENT, OB-GYN, plastic, endoscopic). Combines fluid evacuation with low-energy electrosurgical coagulation. Operated by surgeons; provides simultaneous suction and coagulation to manage tissue and fluids during procedures. Benefits include improved surgical site visibility and hemostasis control.
Clinical Evidence
Bench testing only. Compliance with IEC 601-1-2, IEC 601-2-2, and ANSI/AAMI HF 18 standards for electrosurgical safety. Biocompatibility testing per ISO 10993-1 (Category A). Sterility validated to SAL 10^-6 via 100% Ethylene Oxide (EtO) per AAMI ST27-1988.
Technological Characteristics
Disposable bipolar electrosurgical instrument. Materials biocompatibility tested per ISO 10993-1. Sterilization: 100% Ethylene Oxide (EtO) per AAMI ST27-1988. Electrical safety compliance: IEC 601-1-2 (1988), IEC 601-2-2 (1991), and ANSI/AAMI HF 18 (1993).
Indications for Use
Indicated for soft tissue surgical procedures requiring fluid evacuation and low energy coagulation; applicable in neurosurgery, endoscopic, sinusoidial, ENT, OB-GYN, and plastic surgery.
Regulatory Classification
Identification
An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.
Predicate Devices
- Bipolar Suction Coagulator (K960455)
Related Devices
- K033003 — SUCTION COAGULATOR · Modern Medical Equipment Mfg., Ltd. · May 13, 2004
- K982746 — MONOPOLAR SUCTION COAGULATOR, MODEL # SB 110-1 · New Deantronics Taiwan , Ltd. · Sep 14, 1998
- K122949 — MEDLINE SUCTION COAGULATOR · Medline Industries, Inc. · Oct 16, 2013
- K033257 — ARTHROCARE ENT PLASMA WANDS · Arthrocare Corp. · Oct 30, 2003
- K203745 — AURORA Evacuator +Coag · Rebound Therapeutics · Dec 2, 2021