K970987 · Fusion Medical Technologies, Inc. · GEI · May 5, 1997 · General, Plastic Surgery
Device Facts
Record ID
K970987
Device Name
ELECTROSURGICAL ELECTRODE
Applicant
Fusion Medical Technologies, Inc.
Product Code
GEI · General, Plastic Surgery
Decision Date
May 5, 1997
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 878.4400
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
Intended for use by practitioners in a manner identical to similar electrosurgical electrodes of this type presently in commercial distribution. It is intended to provide electrocautery over a large surface.
Device Story
Fusion Ball Tip Electrode; reusable monopolar electrosurgical accessory. Input: electrical energy from standard electrosurgical generator via electrosurgical pencil/chuck. Operation: delivers high-frequency current to tissue via 99% pure silver ball tip for electrocautery. Used by clinicians in surgical/clinical settings. Output: thermal tissue effect (coagulation/cautery). Benefits: provides large surface area electrocautery; reusable design via autoclave sterilization.
Clinical Evidence
Bench testing only; no clinical data provided. Equivalence based on design, material biocompatibility, and intended use similarity to predicate.
Indicated for use by practitioners for electrocautery over a large surface area in patients requiring electrosurgical procedures.
Regulatory Classification
Identification
An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.
Predicate Devices
Electrosurgical Electrode by Premier Dental Products (K923332)
Related Devices
K972335 — CLEANCUT · Medquest Products, Inc. · Jan 7, 1999
K232460 — Disposable electrosurgical pencil (MD1000) · Shenzhen Mecun Medical Supply Co., Ltd. · Oct 11, 2023
K972497 — KARL STORZ MONOPOLAR COAGULATING ELECTRODES/ KARL STORZ MONOPOLAR COAGULATING NEEDLE ELECTRODES · KARL STORZ Endoscopy-America, Inc. · Aug 27, 1997
K152059 — Disposable General Electrode · Modern Medical Equipment Manufacturing Limited · Apr 21, 2016
K153265 — New Deantronics Disposable Laparoscopic Electrodes, non-coated, and coated · New Deantronics Taiwan , Ltd. · Jan 5, 2016
Submission Summary (Full Text)
{0}
046
K970987
510(k) Summary
Fusion Medical Technologies, Inc.
Ball Tip Electrode
MAY - 5 1997
1. Sponsor: Fusion Medical Technologies, Inc.
1615 Plymouth Street
Mountain View, CA 94043
Contact Person: Debera Brown
Vice President, Regulatory and Clinical Affairs
2. Device Name:
Trade Name: To Be Determined
Common/Usual Name: Electrosurgical Electrode
Classification Name: Electrosurgical Cutting and Coagulation Device and Accessories
3. Identification of the Predicate or Legally Marketed Devices to Which Equivalence is being Claimed:
Electrosurgical Electrode by Premier Dental Products
4. Device Description:
The Fusion Ball Tip Electrode is a reusable electrode for use in monopolar electrosurgical accessories.
5. Intended Use:
Intended for use by practitioners in a manner identical to similar electrosurgical electrodes of this type presently in commercial distribution. It is intended to provide electrocautery over a large surface.
{1}
047
6. A Statement of How the Technological Characteristics of the Device Compare to Those of the Predicate or Legally Marketed Device.
| Parameter | Fusion Ball Tip Electrode | Premier Dental Electrode K923332 |
| --- | --- | --- |
| Indications for Use | Intended for use by practitioners in a manner identical to similar electrosurgical electrodes of this type presently in commercial distribution. It is intended to provide electrocautery over a large surface. | Intended for use by practitioners in a manner identical to similar electrosurgical electrodes of this type presently in commercial distribution. It is intended for cutting and coagulation of tissue. |
| Use Profile | Provided Sterile; reusable after cleaning and autoclave sterilization | Provided non-sterile; first use and reuse after autoclave or ETO sterilization |
| Compatibility | Standard 3/32 inch (2.4 mm) shaft fits most electrosurgery chucks and pencils | 44 different configurations provided, all standard 3/32 shaft to fit most electrosurgery chucks and pencils |
| Material Composition | Stainless Steel shank, Polyphenylsulfone for insulation, 99% Pure Silver as electrode tip | Stainless Steel shank, Korvex 4X Teflon TFE heat shrinkable tubing, Type 304 stainless steel electrode tip |
| Sterilization | Provided sterile by gamma irradiation for first use | Provided non-sterile, must be sterilized by user before first use |
| Biocompatibility | Materials used in other medical devices; ISO 10993-1 | Materials used in other devices |
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.