K993146 · Dornier Surgical Products, Inc. · GEX · Nov 8, 1999 · General, Plastic Surgery
Device Facts
Record ID
K993146
Device Name
DORNIER SCANNER HANDPIECE
Applicant
Dornier Surgical Products, Inc.
Product Code
GEX · General, Plastic Surgery
Decision Date
Nov 8, 1999
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 878.4810
Device Class
Class 2
Attributes
Therapeutic
Intended Use
The Dornier Scanner handpiece is intended to be used in general and surgical procedures for incision / excision, vaporization, and coagulation of soft tissue and cartilage. The Dornier Scanner may also be used for skin resurfacing. The Dornier Scanner is for use as an accessory for the Dornier Medilas E Laser (K981438). It is indicated for use in medicine and surgery in the medical specialties as listed in the Indication for Use Statement for the Dornier Medilas E Laser System. No new indications are being requested.
Device Story
Dornier Scanner is a laser handpiece accessory for the Dornier Medilas E Laser system. It functions as a beam delivery/scanning device to facilitate surgical procedures including incision, excision, vaporization, ablation, and coagulation of soft tissue and cartilage, as well as skin resurfacing. Operated by physicians in surgical or clinical settings, the device directs laser energy to target tissues. It serves as an interface between the laser source and the patient, allowing for controlled tissue interaction. The device benefits patients by enabling precise surgical outcomes through automated or guided laser delivery.
Clinical Evidence
No clinical data provided; substantial equivalence is based on design and technological comparisons to predicate devices.
Technological Characteristics
Laser handpiece accessory for use with the Dornier Medilas E Laser. Functions as a beam delivery system for surgical laser applications. Design and performance characteristics are consistent with existing laser scanning handpieces.
Indications for Use
Indicated for patients requiring incision, excision, vaporization, ablation, or coagulation of soft tissue and cartilage, and for skin resurfacing, as performed by the Dornier Medilas E Laser system.
Regulatory Classification
Identification
(1) A carbon dioxide laser for use in general surgery and in dermatology is a laser device intended to cut, destroy, or remove tissue by light energy emitted by carbon dioxide.(2) An argon laser for use in dermatology is a laser device intended to destroy or coagulate tissue by light energy emitted by argon.
K992084 — CYNOSURE SURESCAN WITH THE CO3 ER: YAG LASER · Cynosure, Inc. · Jul 12, 1999
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows the logo for Dornier MedTech. The logo consists of a stylized figure of a person with outstretched arms, followed by the company name in a bold, sans-serif font. The text is black, and the figure is also black.
# K 99314 6
## 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS Dornier Surgical Products, Inc.'s Scanner for Medilas E Laser
In response to the Safe Medical Devices Act of 1990, the following is a summary of the safety and effectiveness information upon which the substantial equivalence determination is based.
The safety and effectiveness of the Dornier Scanner is based upon a determination of the substantial equivalence as well as the safety and effectiveness of its predicate devices, which includes the following: Dornier VarioSpot 90 handpiece (K981438) and Coherent's Computerized Pattern Generator (CPG) (K946304) scanner.
#### Submitter's Name, Address, Telephone Number, Contact Person and Date Prepared
| Dornier Surgical Products, Inc.<br>10027 South 51st Street<br>Phoenix, AZ 85044 | Phone: 770-693-5793<br>Facsimile: 770-693-5770<br>Date Prepared: September 13, 1999 |
|---------------------------------------------------------------------------------|-------------------------------------------------------------------------------------|
| Contact Person: Carol Wernecke | Phone: 770-426-1315<br>Fax: 770-514-6288 |
#### Name of Device and Name/Address of Sponsor
Dornier Scanner Dornier Surgical Products, Inc. 10027 South 51st Street Phoenix, AZ 85044
#### Classification Name
ER:YAG lasers and their accessories have not been specifically classified by FDA.
#### Predicate Devices
Dornier VarioSpot 90 handpiece (K981438) Coherent's Computerized Pattern Generator (CPG) (K946304) scanner
#### Intended Use
The Dornier Scanner handpiece is intended to be used in general and surgical procedures for incision / excision, vaporization, and coagulation of soft
{1}------------------------------------------------
tissue and cartilage. The Dornier Scanner may also be used for skin resurfacing.
The Dornier Scanner is for use as an accessory for the Dornier Medilas E Laser (K981438). It is indicated for use in medicine and surgery in the medical specialties as listed in the Indication for Use Statement for the Dornier Medilas E Laser System.
No new indications are being requested.
#### Technological Characteristics and Substantial Equivalence
From a clinical perspective and comparing design specifications, the Dornier Scanner and the predicate devices are substantially equivalent and have the same intended use. Based on the technological characteristics and overall performance of the devices, Dornier Surgical Products, Inc. believes that no significant differences exist between the Dornier Scanner and the predicate devices. Dornier VarioSpot 90 handpiece (K981438) and Coherent's Computerized Pattern Generator (CPG) (K946304) scanner.
Dornier Surgical Products, Inc. believes the minor differences of the Dornier Scanner and its predicate laser devices should not raise any concerns regarding the overall safety or effectiveness.
- This information was prepared for the sole purpose of compliance Advisory: with the Safe Medical Devices Act of 1990. It does not imply that the procedures described herein can be performed with the equipment described without substantial risk of personal injury or death to patients due to operator error or in procedures requiring a high degree of skill.
{2}------------------------------------------------
Image /page/2/Picture/1 description: The image is a black and white logo for the U.S. Department of Health & Human Services. The logo features a stylized depiction of three overlapping human figures, representing the department's focus on people. The figures are arranged in a way that suggests movement or progress. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the symbol.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
NOV - 8 1999
Ms. Carol Wernecke Dornier Surgical Products, Inc. c/o Dornier Medical Systems, Inc. 1155 Roberts Boulevard Kennesaw, Georgia 30144
Re: K993146 Trade Name: Dornier Scanner Handpiece Regulatory Class: II Product Code: GEX Dated: September 15, 1999 Received: September 20, 1999
Dear Ms. Wernecke:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Ouality System Regulation (OS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register, Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
{3}------------------------------------------------
#### Page 2 - Ms. Carol Wernecke
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4595. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours,
Celia M. Witten, Ph.D., M.D.
Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
# PREMARKET NOTIFICATION
### INDICATIONS FOR USE STATEMENT
1993146 510(k) Number:
Device Name:
Dornier Scanner
Indications for Use:
The Dornier Scanner handpiece is intended to be used in general and surgical procedures for incision / excision, vaporization, ablation, and coagulation of soft tissue and cartilage. The Dornier Scanner may also be used for skin resurfacing.
The Dornier Scanner is for use as an accessory for the Dornier Medilas E Laser (K981438). It is indicated for use in medicine and surgery in the medical specialties as listed in the Indication for Use Statement for the Dornier Medilas E Laser System.
No new indications are being requested.
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use X or Over-the-Counter Use
(Division Sign-Off)
ion of General Restorative Devices K993146
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.