FOTONA SKINSCAN
Device Facts
| Record ID | K970757 |
|---|---|
| Device Name | FOTONA SKINSCAN |
| Applicant | Medical Laser Solutions |
| Product Code | GEX · General, Plastic Surgery |
| Decision Date | May 9, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 878.4810 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Intended Use
The Fotona Skinscan system is a microprocessor controlled device which generates precisely defined patterns on skin tissue in an automated sequence to increase uniformity and ease of treatment when used in conjunction with a host Skinlight system.
Device Story
Microprocessor-controlled accessory for Fotona Skinlight laser; generates automated, uniform laser patterns on skin tissue. Comprises scanner handpiece (with smoke evacuation/distance gauge), scanner head (mirrors/optics), and electronic control box (mirror control/laser interface). Integrated with host laser; host recognizes accessory presence to enable scanner-specific menu modes. Used by clinicians in dermatological settings to improve treatment uniformity and ease of operation. Output is controlled laser beam delivery in defined patterns. Benefits include increased procedural consistency and simplified laser application.
Clinical Evidence
Bench testing only; no clinical data provided.
Technological Characteristics
Microprocessor-controlled laser scanning accessory. Components: scanner handpiece, scanner head with mirrors/optics, electronic control box. Connectivity: physical cable interface to host laser system. Software: embedded firmware for scanner-specific menu modes and mirror control.
Indications for Use
Indicated for use as an accessory to the Fotona Skinlight laser system to generate automated, uniform laser patterns on skin tissue.
Regulatory Classification
Identification
(1) A carbon dioxide laser for use in general surgery and in dermatology is a laser device intended to cut, destroy, or remove tissue by light energy emitted by carbon dioxide.(2) An argon laser for use in dermatology is a laser device intended to destroy or coagulate tissue by light energy emitted by argon.
Predicate Devices
- Coherent CPG system (K946304)
Related Devices
- K971903 — SCANNING DEVICE ACCESSORY FOR USE WITH THE CB DIODE/532 ND:YAG LASER · Continuum Biomedical, Inc. · Aug 21, 1997
- K982295 — NIDEK LIGHTSCAN · Nidek, Inc. · Aug 6, 1998
- K971879 — SCANNING DEVICE ACCESSORY FOR USE WITH THE CB ERBIUM/2.94 ER:YAG LASER · Continuum Biomedical, Inc. · Aug 14, 1997
- K964684 — SOFTOUCH · Sahar Technologies, Inc. · Feb 14, 1997
- K972028 — DERMASCAN SURGICAL LASER SCANNER · Esc Medical Systems , Ltd. · Oct 24, 1997