PALOMAR LUX1064 HANDPIECE

K041879 · Palomar Medical Technologies, Inc. · GEX · Jan 13, 2005 · General, Plastic Surgery

Device Facts

Record IDK041879
Device NamePALOMAR LUX1064 HANDPIECE
ApplicantPalomar Medical Technologies, Inc.
Product CodeGEX · General, Plastic Surgery
Decision DateJan 13, 2005
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 878.4810
Device ClassClass 2
AttributesTherapeutic

Intended Use

The Lux1064™ is a light-based medical device designed for effective removal of unwanted hair, permanent hair reduction, PFB, treatment of wrinkles and the treatment of vascular and pigmented lesions.

Device Story

The Lux1064™ Nd:YAG handpiece is an attachment for the Palomar StarLux™ Pulsed Light System. It delivers light-based energy to target skin and soft tissue. Used by clinicians in medical settings, the device treats vascular and pigmented lesions, removes hair, reduces scars, and performs soft tissue coagulation/hemostasis. The clinician operates the handpiece to apply energy to the patient's skin; the system's light output interacts with target chromophores or tissues to achieve the desired therapeutic effect. The device provides a non-invasive or minimally invasive option for dermatological and surgical conditions, potentially benefiting patients by reducing lesion size, improving skin appearance, or managing hair growth and scarring.

Clinical Evidence

No clinical data provided; substantial equivalence is based on technological characteristics and performance comparisons to legally marketed predicate devices.

Technological Characteristics

Nd:YAG laser handpiece attachment for the StarLux™ base unit. Operates as a light-based surgical instrument (21 CFR 878.4810). Designed for dermatological and general/plastic surgery applications. Energy source is laser-based. System is a modular handpiece-and-base-unit configuration.

Indications for Use

Indicated for removal of unwanted hair (skin types I-VI) and permanent hair reduction; treatment of benign pigmented lesions (e.g., age spots, sun spots, seborrheic keratoses, nevi, chloasma, café-au-lait macules, plaques, verrucae, skin tags); tattoo reduction (black/blue-black); treatment of vascular lesions (e.g., port wine stains, hemangiomas, telangiectasias, rosacea, venous lake, facial/leg veins); reduction of red pigmentation in hypertrophic/keloid scars; coagulation and hemostasis of soft tissue; treatment of wrinkles; and Pseudofolliculitis barbae (PFB).

Regulatory Classification

Identification

(1) A carbon dioxide laser for use in general surgery and in dermatology is a laser device intended to cut, destroy, or remove tissue by light energy emitted by carbon dioxide.(2) An argon laser for use in dermatology is a laser device intended to destroy or coagulate tissue by light energy emitted by argon.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K041879 1/2 JAN 13 2005 ## Attachment 4 ## 510(K) Summary of Safety and Effectiveness This 510(K) Summary of Safety and Effectiveness for the Palomar StarLux™ Pulsed Light This JTV(K) Sullimary of Safety and Enterty, and Enternets of Safe Medical Device Act System is submitted in accordance with the requirements of Safe Medical Device Act System is submitted in accordance with the requestion (ODE) guidance concerning the organization and content of a 510(K) summary. | Applicant: | Palomar Medical Technologies, Inc. | |------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Address: | 82 Cambridge St.<br>Burlington, MA 01803<br>781-993-2300 | | Contact Person: | Marcy Moore | | Telephone: | 919-363-2432 | | Preparation Date: | July 8, 2004 | | Device Trade Name: | Palomar Lux1064™ NdYAG Handpiece | | Common Name: | Lux1064™ | | Classification Name: | Laser surgical instrument for use in General and<br>Plastic Surgery and in Dermatology<br>(see: 21 CFR 878-4810).<br>Product Code: GEX<br>Panel: 79 | | Legally-Marketed Predicate Device: | StarLux™ Pulsed Light System (handpieces)<br>Lumenis Family of IPL & IPL/NdYAG, Candela<br>Gentle YAG, Laserscope LIRA | | System Description: | The Lux1064™ is a versatile, light-based medical<br>device consisting of a base unit and handpiece<br>attachments. | | Intended Use of the Device: | The Lux1064™ is a light-based medical device<br>designed for effective removal of unwanted hair,<br>permanent hair reduction, PFB, treatment of wrinkles<br>and the treatment of vascular and pigmented lesions. | {1}------------------------------------------------ K041879 2/2 Performance Data: Conclusion: The differences in the specifications of the Lux1064™ and the predicate devices do not result in different performance or raise new questions of safety or efficacy. Based on the foregoing, the Lux1064™ System is substantially equivalent to the legally-marketed claimed predicate devices, i.e., the Lumenis IPL/NdYAG, Candela GentleYAG, and Laserscope Lyra series. {2}------------------------------------------------ DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is circular and contains the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. In the center of the circle is a stylized symbol that resembles three overlapping human figures. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 JAN 1 3 2005 Palomar Medical Technologies, Inc. c/o Ms. Marcy Moore Manager of Clinical Studies 131 Kelekent Lane Cary, North Carolina 27511 Re: K041879 Trade/Device Name: Palomar Lux1064™ Nd: YAG Handpiece Regulation Number: 21 CFR 878.4810 Regulation Name: Laser surgical instrument for use in general and plastic surgery and in dermatology Regulatory Class: II Product Code: GEX Dated: October 22, 2004 Received: October 25, 2004 Dear Ms. Moore: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act s requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {3}------------------------------------------------ Page 2 – Ms. Marcy Moore This letter will allow you to begin marketing your device as described in your Section 510(k) rms leter notification. The FDA finding of substantial equivalence of your device to a legally , marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours, Muriam C. Provost Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ ## INDICATIONS FOR USE STATEMENT 510(K) Number: Device Name: Palomar Lux 1064TM Nd: Y AG Handpiece Indications for Use: The Lux1064TM handpiece is indicated for: - The removal of unwanted hair for skin types I-VI, and to effect . stable long-term permanent hair reduction. - The treatment of benign pigmented lesions such as, but not t limited to, senile lentigines (age spots), solar lentigos (sun spots), pigmented seborrheic keratoses, nevi, chloasma, caféau-lait macules, and plaques. - . Verrucae, skin tags, seborrheic keratosis, - Tattoos (significant reduction in the intensity of black and/or 속 blue-black tattoos). - The Lux1064™ is indicated for pigmented lessons to reduce . lesion size, for patients with lesions that would potentially benefit from aggressive treatment, and for patients with lesions that have not responded to other laser/light treatments. - The treatment of vascular lesions such as but not limited to, . port wine stains, hemangiomas, telangiectasias, rosacea, Venus lake, facial and leg veins. - The Lux10641M is also indicated for the reduction of red ◆ pigmentation in hypertrophic and keloid scars where vascularity is an integral part of the scar. - Coagulation and hemostasis of soft tissue. ● - ♥ Treatment of wrinkles. - Pseudofolliculitis barbae (PFB) ● Prescription Use (per 21 CFR 801.109) OR Over-the-Counter Use (Please do not write below this line - Continue on another page if needed) Concurrence of CDRH, Office of Device Evaluation (ODE) Miriam' ( Provost (Division Sign-Off) Division of General, Restorative, and Neurological Devices 510(k) Number_4/4/877
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...