K970826 · Microline Pentax, Inc. · GEI · Mar 28, 1997 · General, Plastic Surgery
Device Facts
Record ID
K970826
Device Name
SELECTA-TIP LAPAROSCOPIC SCISSORS
Applicant
Microline Pentax, Inc.
Product Code
GEI · General, Plastic Surgery
Decision Date
Mar 28, 1997
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 878.4400
Device Class
Class 2
Indications for Use
Selecta-Tip Laparoscopic scissors tips are intended for use to cut and dissect various abdominal tissue in endoscopic, including laparoscopic surgical procedures where instruments are introduced into the body through a cannula.
Device Story
Manual detachable surgical instrument system; reusable handles attach to interchangeable scissors tips. Tip configurations include Metzenbaum, Mini, Hook, Endocut, and Micro. Proprietary single thread and ball attachment mechanism. Used by surgeons in endoscopic/laparoscopic procedures to cut/dissect tissue. Device provides mechanical cutting functionality; no electronic or software components.
Clinical Evidence
No clinical data; bench testing only.
Technological Characteristics
Manual surgical instrument; reusable stainless steel components; proprietary single thread and ball attachment system; mechanical cutting action; non-powered; manual operation.
Indications for Use
Indicated for cutting and dissecting abdominal tissue during endoscopic and laparoscopic surgical procedures via cannula access.
Regulatory Classification
Identification
An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.
{0}
10. SMDA Summary of Safety and Effectiveness - "510(k) Summary"
K 97 0826
# A. Submitter Information
Microline, Inc.
181 Elliott Street
Beverly, MA 01915
Telephone: (508) 922-9810
Contact Person: Mr. Huges de Laforcade
President
Date Prepared: March 3, 1997
MAR 28 1997
# B. Device Identification
Common/Usual Name: Manual Detachable Surgical Instruments
Proprietary Name: "Selecta-Tip" Laparoscopic Scissors Tips
# C. Identification of Predicate Device(s)
The "Selecta-Tip" Laparoscopic Instruments are substantially equivalent to their predicate, "Re-New (K962119), previously cleared and currently marketed.
# D. Device Description
The Selecta-Tip" Laparoscopic Scissors are surgical blades used to cut and dissect various abdominal tissue for use in endoscopic, including laparoscopic, surgical procedures. The product line includes reusable common handles that can be easily attached and detached from a series of reusable tips.
The tip assembly is designed with a proprietary single thread and ball system, which permits simple and reliable attachment and detachment of the desired tip to the shaft of the handle/shaft component. Scissors tip configurations include:
- Metzenbaum,
- Mini,
- Hook,
- Endocut, and
- Micro.
# E. Substantial Equivalence
The technical characteristics of the "Selecta-Tip" Laparoscopic scissors tips are almost identical to those of the Microline "Re-New". Differences that exist between these devices relating to technical specifications, materials, and physical appearance do not affect the relative safety or effectiveness of the "Selecta-Tip" relative to its predicate.
"Selecta-Tip" Laparoscopic scissors tips are intended for use to cut and dissect various abdominal tissue in endoscopic, including laparoscopic surgical procedures where instruments are introduced into the body through a cannula.
000007