DAVIS BAYONET ELECTRODES
Device Facts
| Record ID | K964602 |
|---|---|
| Device Name | DAVIS BAYONET ELECTRODES |
| Applicant | Valleylab, Inc. |
| Product Code | GEI · General, Plastic Surgery |
| Decision Date | Jan 9, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 878.4400 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
Davis Bayonet Electrodes are intended for use in open surgical procedures where monopolar electrosurgical cutting and coagulation are normally used. The Electrodes are intended for use in conventional electrosurgical pencils and chucks as alternatives to other electrosurgical electrodes.
Device Story
Sterile, single-use electrosurgical electrodes; extended shaft with offset bayonet shape; loop, ball, and needle tip configurations. Used in open surgery within cavities or recessed areas to improve surgeon visibility. Compatible with conventional electrosurgical pencils and chucks. Operates by conducting high-frequency electrical current from electrosurgical generators to patient tissue for cutting and coagulation. Used by surgeons in clinical/OR settings. Benefits include enhanced visualization in deep surgical sites compared to straight electrodes.
Clinical Evidence
Bench testing only. Functional testing performed on chicken breast tissue; insulation tested at 60Hz and radio frequencies; assembly and removal force testing; environmental, vibration, and drop testing for packaging.
Technological Characteristics
Monopolar electrosurgical electrodes; loop, ball, or needle tips; extended bayonet-shaped shaft. Complies with AAMI HF18 (1993) and IEC 601-2-2 (1991-09). Sterile, single-use. Compatible with standard electrosurgical pencils.
Indications for Use
Indicated for patients undergoing open surgical procedures requiring monopolar electrosurgical cutting and coagulation.
Regulatory Classification
Identification
An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.
Predicate Devices
- Valleylab E1000 series Electrodes
- Valleylab E1550 series Electrodes
Related Devices
- K974735 — STANDARD AND EXTENDED BLADE, NEEDLE AND BALL; MODIFIED STANDARD AND EXTENDED BLADE & NEEDLE; STANDARD 45 DEGREE BLADE · Aaron Medical Industries · Jun 24, 1998
- K962935 — UNIMED COATED NEEDLE ELECTRODE/COATED BLADE ELECTRODE/COATED BALL ELECTRODE · Unimed Surgical Products, Inc. · Sep 3, 1996
- K163442 — Single Use Micro Electrode (Brass with gold plated shaft); Single Use Micro Electrode (Stainless Steel shaft) · Modern Medical Equipment Manufacturing Limited · Sep 28, 2017
- K142410 — Elliquence Electrodes · Elliquence, LLC · Oct 30, 2015
- K972335 — CLEANCUT · Medquest Products, Inc. · Jan 7, 1999