← Product Code [GDW](/submissions/SU/subpart-e%E2%80%94surgical-devices/GDW) · K141952

# ECHELON FLEX POWERED VASCULAR STAPLER WITH ADVANCED PLACEMENT TIP, ENDOPATH ECHELON VASCULAR WHITE RELOADS FOR ADVANCED (K141952)

_Ethicon Endo-Surgery, Inc. · GDW · Nov 24, 2014 · General, Plastic Surgery · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/GDW/K141952

## Device Facts

- **Applicant:** Ethicon Endo-Surgery, Inc.
- **Product Code:** [GDW](/submissions/SU/subpart-e%E2%80%94surgical-devices/GDW.md)
- **Decision Date:** Nov 24, 2014
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 878.4750
- **Device Class:** Class 2
- **Review Panel:** General, Plastic Surgery
- **Attributes:** Therapeutic, Pediatric

## Indications for Use

The Echelon Flex™ Powered Vascular Stapler with Advanced Placement Tip and its reloads are intended for transection and resection of tissue and vasculature. The instruments have application in multiple open or minimally invasive general, gynecologic, urologic, thoracic, and pediatric surgical procedures.

## Device Story

Powered surgical stapler; performs simultaneous tissue/vasculature transection and resection. Device consists of powered handle, articulating shaft, and replaceable reload cartridge. Input: manual operation by surgeon; battery-powered motor drives staple firing and cutting. Output: four staggered rows of titanium staples with central cut line. Used in OR for open/minimally invasive procedures. Features include active articulation, narrow shaft, and curved anvil tip for access to confined spaces. Lockout mechanism prevents firing without reload or with used reload. Benefits: facilitates access to difficult-to-reach vessels; provides hemostasis via staple line.

## Clinical Evidence

Bench testing and animal studies performed. Bench testing evaluated force-to-close, staple height, staple form, staple line integrity, electrical safety, electromagnetic compatibility, MR compatibility, and biocompatibility. Animal testing (acute and survival models) evaluated hemostasis performance. No human clinical data provided.

## Technological Characteristics

Powered handle with primary lithium battery. Titanium alloy staples. 35mm staple line, 30mm cut line. 4-row staggered staple configuration. Features active articulation, narrow shaft, and curved anvil tip. Sterile, single-patient use. Electrical safety and EMC compliant.

## Regulatory Identification

An implantable staple is a staple-like device intended to connect internal tissues to aid healing. It is not absorbable.

## Predicate Devices

- Echelon Flex Powered Articulating Endoscopic Linear Cutters, 45mm, 60mm ([K110385](/device/K110385.md), [K081146](/device/K081146.md))
- ENDOPATH ETS Flex Articulating Linear Cutter, 35mm ([K111111](/device/K111111.md), [K070887](/device/K070887.md), [K020779](/device/K020779.md))
- Echelon Endoscopic Linear Cutter Reload, White ([K121600](/device/K121600.md), [K081146](/device/K081146.md), [K070887](/device/K070887.md))
- ENDOPATH ETS Endoscopic Reload, White (K11111, [K070887](/device/K070887.md), [K020779](/device/K020779.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Image /page/0/Picture/1 description: The image shows the seal of the U.S. Department of Health and Human Services. The seal is circular and contains the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. In the center of the seal is an abstract image of three faces in profile, stacked on top of each other, resembling a stylized bird.

Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002

November 24, 2014

Ethicon Endo-Surgery, LLC. % Ms. Linda Hill Ethicon Endo-Surgery Incorporated 4545 Creek Road Cincinnati Ohio 45242

Re: K141952

Trade/Device Name: Echelon Flex™ Powered Vascular Stapler with Advanced Placement Tip, and Endopath Echelon™ Vascular White Reloads for Advanced Placement Tip Regulation Number: 21 CFR 878.4750 Regulation Name: Implantable staple Regulatory Class: Class II Product Code: GDW Dated: October 25, 2014 Received: October 27, 2014

Dear Ms. Hill:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you; however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must

{1}------------------------------------------------

Page 2 - Ms. Linda Hill

comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.

Sincerely yours.

# David Krause -S

for

Binita S. Ashar, M.D., M.B.A., F.A.C.S. Director Division of Surgical Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

# Indications for Use

K141952

510(k) Number (if known) To be assigned

↑

Device Name

Echelon Flex™ Powered Vascular Stapler with Advanced Placement Tip, and Endopath Vascular White Reloads for Advanced Placement Tip

#### Indications for Use (Describe)

The Echelon Flex™ Powered Vascular Stapler with Advanced Placement Tip and its reloads are intended for transection and resection of tissue and vasculature. The instruments have application in multiple open or minimally invasive general, gynecologic, urologic, thoracic, and pediatric surgical procedures.

Type of Use (Select one or both, as applicable)

> Prescription Use (Part 21 CFR 801 Subpart D)

_ Over-The-Counter Use (21 CFR 801 Subpart C)

#### PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON A SEPARATE PAGE IF NEEDED.

#### FOR FDA USE ONLY

Concurrence of Center for Devices and Radiological Health (CDRH) (Signature)

This section applies only to requirements of the Paperwork Reduction Act of 1995.

#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

> Department of Health and Human Services Food and Druq Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

{3}------------------------------------------------

## 510(k) Summary

| Company | Ethicon Endo-Surgery, LLC<br>475 Calle C<br>Guaynabo, PR 00969                                                                                                 |
|---------|----------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Contact | Linda Hill<br>Ethicon Endo-Surgery, Inc.<br>Portfolio Leader, Regulatory Affairs<br>Telephone (513) 337-7623<br>Fax (513) 337-2623<br>Email LHILL3@its.jnj.com |

Date Prepared July 17, 2014

#### Device Name

Echelon Flex™ Powered Vascular Stapler with Advanced Placement Tip, Trade Name: and ENDOPATH Echelon™ Vascular White Reloads for Advanced Placement Tip

Common or Usual Name: Surgical Stapler with Implantable Staples

Classification Name: Staple, Implantable

#### Predicate Devices

Echelon Flex Powered Articulating Endoscopic Linear Cutters, 45mm, 60mm (K110385, K081146)

ENDOPATH ETS Flex Articulating Linear Cutter. 35mm (K111111. K070887. K020779) Echelon Endoscopic Linear Cutter Reload, White (K121600, K081146, K070887) ENDOPATH ETS Endoscopic Reload, White (K11111, K 070887, K020779)

## Device Description

The Echelon Flex™ Powered Vascular Stapler with Advanced Placement Tip and ENDOPATH Echelon Vascular White Reload for Advanced Placement Tip (35mm, 4 Row) reloads are sterile, single patient use devices that simultaneously cut and staple tissue. There are four staggered rows of staples, two on either side of the cut line. The Echelon Flex Powered Vascular Stapler with Advanced Placement Tip and reloads have a staple line that is approximately 35 mm long and a cut line that is approximately 30 mm long. The shaft can rotate freely in both directions and an articulation mechanism enables the distal portion of the shaft to pivot to facilitate access to the operative site.

The instrument is packaged with a primary lithium battery pack that must be installed prior to use. The instrument is packaged without a reload and must be loaded prior to use. A staple retaining cap on the reload protects the staple leg points during shipping, transporting, and installing the reload. The instrument's lockout feature is designed to prevent a used or improperly installed reload from being refired or an instrument from being fired without a reload.

{4}------------------------------------------------

## Indications for Use

The Echelon Flex™ Powered Vascular Stapler with Advanced Placement Tip and its reloads are intended for transection and resection of tissue and vasculature. The instruments have application in multiple open or minimally invasive general, gynecologic, urologic, thoracic, and pediatric surgical procedures.

## Technological Characteristics

The subject Echelon Flex™ Powered Vascular Stapler with Advanced Placement Tip instrument is similar to the predicate Echelon Flex Powered Articulating Endoscopic Linear Cutters with respect to the powered handle, and closure and firing design for minimal tip movement. The subject instrument is similar to the predicate ENDOPATH ETS Flex 35mm Articulating Linear Cutter and Reloads with respect to the active articulation feature and to the tissue compression aspects of the end effector, with similar jaw length and staple line length. As compared with the predicate devices, the subject Echelon Flex™ Powered Vascular Stapler with Advanced Placement Tip instrument incorporates several design enhancements - including a narrower diameter shaft, narrower end effector tip, curved anvil tip, introducer-like cartridge body tip, and active articulation with higher maximum articulation angles - which facilitate access in surgical procedures with smaller surgical spaces or difficult-to-reach vessels.

The subject reload, the ENDOPATH Echelon™ Vascular White Reloads for Advanced Placement Tip, is similar to the predicate ENDOPATH ETS Endoscopic Reload, White, 35mm with regard to staple material (titanium alloy), reload color (white), intended tissue type (thin/vascular), and closed staple height (1.0mm). The principal difference between the subject reload and predicate reloads is that the subject reload, which features a narrower design, delivers 2 sides of double staggered staple lines, rather than 2 sides of triple staggered staple lines as in the predicate device.

## Performance Data

Testing conducted to demonstrate that the subject device will perform equivalently to the identified predicate devices for the intended use included: bench testing for force-to-close evaluation; staple height, staple form, and staple line integrity evaluation; animal testing for hemostasis evaluation (in acute and survival models); electrical safety and electromagnetic compatibility testing; MR compatibility testing; and aggregate device biocompatibility testing for patient contacting materials.

---

**Source:** [https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/GDW/K141952](https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/GDW/K141952)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
