Pre-Sutured Tendon (4561SC / Single Strand); Pre-Sutured Tendon (4564SC / Quadruple Strand )

K230036 · Rti Surgical, Inc. · GAT · Jun 23, 2023 · General, Plastic Surgery

Device Facts

Record IDK230036
Device NamePre-Sutured Tendon (4561SC / Single Strand); Pre-Sutured Tendon (4564SC / Quadruple Strand )
ApplicantRti Surgical, Inc.
Product CodeGAT · General, Plastic Surgery
Decision DateJun 23, 2023
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 878.5000
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The Pre-Sutured Tendon is intended for use as a construct in anterior cruciate ligament and posterior cruciate ligament reconstruction. The Pre-Sutured Tendon is for single patient use only.

Device Story

Device consists of donated human nonbone tendon pre-sutured with sterile ultra-high-molecular-weight polyethylene (UHMWPE) nonabsorbable sutures; processed via BioCleanse Tissue Sterilization Process. Offered as single or quadruple strand constructs. Used by orthopedic surgeons in clinical settings for ACL/PCL reconstruction. Implanted using traditional surgical methods. Provides structural support for ligament repair; benefits patient by facilitating reconstruction of damaged knee ligaments.

Clinical Evidence

No clinical trials; bench testing and human cadaver study performed. Bench testing included ultimate load, cyclic displacement, suture pull-out, packaging validation, shelf-life, biocompatibility (ISO 10993), and bacterial endotoxin testing. Human cadaver study demonstrated feasibility, confirming device dimensions, configuration, and functionality meet user needs for ACL/PCL reconstruction.

Technological Characteristics

Donated human nonbone tendon; UHMWPE nonabsorbable sutures. Processed via BioCleanse Tissue Sterilization Process. Single or quadruple strand configurations. Dimensions: 180-220mm length (single), 50-70mm (quad); 8.5-13mm diameter. Biocompatibility per ISO 10993.

Indications for Use

Indicated for patients requiring anterior cruciate ligament (ACL) or posterior cruciate ligament (PCL) reconstruction.

Regulatory Classification

Identification

Nonabsorbable poly(ethylene terephthalate) surgical suture is a multifilament, nonabsorbable, sterile, flexible thread prepared from fibers of high molecular weight, long-chain, linear polyesters having recurrent aromatic rings as an integral component and is indicated for use in soft tissue approximation. The poly(ethylene terephthalate) surgical suture meets U.S.P. requirements as described in the U.S.P. Monograph for Nonabsorbable Surgical Sutures; it may be provided uncoated or coated; and it may be undyed or dyed with an appropriate FDA listed color additive. Also, the suture may be provided with or without a standard needle attached.

Special Controls

*Classification.* Class II (special controls). The special control for this device is FDA's “Class II Special Controls Guidance Document: Surgical Sutures; Guidance for Industry and FDA.” See § 878.1(e) for the availability of this guidance document.

Predicate Devices

Submission Summary (Full Text)

{1}------------------------------------------------ Image /page/0/Picture/0 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). The logo consists of two parts: the Department of Health & Human Services logo on the left and the FDA text logo on the right. The text logo has the FDA acronym in a blue square, followed by the words "U.S. FOOD & DRUG ADMINISTRATION" in blue. June 23, 2023 RTI Surgical, Inc Ellen Rounds Director Regulatory Affairs 11621 Research Circle Alachua, Florida 32615 Re: K230036 Trade/Device Name: Pre-Sutured Tendon Regulation Number: 21 CFR 878.5000 Regulation Name: Nonabsorbable Poly(Ethylene Terephthalate) Surgical Suture Regulatory Class: Class II Product Code: GAT Dated: May 24, 2023 Received: May 24, 2023 Dear Ellen Rounds: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {2}------------------------------------------------ Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems. For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely. Jesse Muir -S Jesse Muir, PhD Assistant Director DHT6C: Division of Restorative, Repair and Trauma Devices OHT6: Office of Orthopedic Devices Office of Product Evaluation and Ouality Center for Devices and Radiological Health Enclosure {3}------------------------------------------------ ## Indications for Use 510(k) Number (if known) K230036 Device Name Pre-Sutured Tendon Indications for Use (Describe) The Pre-Sutured Tendon is intended for use as a construct in anterior cruciate ligament and posterior cruciate ligament reconstruction. The Pre-Sutured Tendon is for single patient use only. | Type of Use (Select one or both, as applicable) | | |----------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------| | <div> <span> <span style="font-size: large;">☑</span> Prescription Use (Part 21 CFR 801 Subpart D) </span> </div> | <div> <span> <span style="font-size: large;">☐</span> Over-The-Counter Use (21 CFR 801 Subpart C) </span> </div> | ## CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. ## *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {4}------------------------------------------------ Image /page/3/Picture/0 description: The image shows the logo for RTI Surgical. The logo consists of the letters "rti" in a blue square with a rounded corner. To the right of the square, the word "surgical" is written in gray letters. The logo is simple and modern. ## 510(k) Summary K230036 | Date Prepared | June 22, 2023 | | | | | | | | | | | | | |----------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|--|--|--|--|--|--|--|--|--|--|--| | Submitter | RTI Surgical, Inc. 11621 Research Circle<br>Alachua, FL 32615 USA | | | | | | | | | | | | | | Contact<br>Information | Ellen Rounds<br>Sr. Regulatory Affairs Specialist<br>Email: erounds@rtix.com | | | | | | | | | | | | | | Name of Device | Pre-Sutured Tendon | | | | | | | | | | | | | | Common Name | Pre-Sutured Tendon | | | | | | | | | | | | | | Classification<br>Name | Suture, Nonabsorbable, Synthetic, Polyethylene | | | | | | | | | | | | | | Regulation<br>Number | 21 CFR 878.5000 | | | | | | | | | | | | | | Regulatory<br>Class | Class II | | | | | | | | | | | | | | Product Code | GAT | | | | | | | | | | | | | | Panel | General and Plastic Surgery | | | | | | | | | | | | | | Legally Marketed<br>Predicate<br>Device(s) | K181633 MTF Pre-Sutured Tendon<br>K170957 Allosource ReConnex Pre-Sutured Tendon | | | | | | | | | | | | | | Device Description | The Pre-Sutured Tendon is a donated human nonbone tendon pre-sutured with<br>sterile Ultra-high-molecular-weight polyethylene (UHMWPE) nonabsorbable<br>sutures. The tendon is processed via the BioCleanse® Tissue Sterilization<br>Process (The BioCleanse Process). The Pre-Sutured Tendon device is offered<br>as a single strand and as a quadruple (quad) strand. | | | | | | | | | | | | | | Dimensions Implant Length (mm) Folded Diameter (mm) Single Strand 180-220 8.5-12 Quadruple Strand 50-70 9.0-13 | | | | | | | | | | | | | | | Indications<br>for Use | The Pre-Sutured Tendon is intended for use as a construct in anterior cruciate<br>ligament and posterior cruciate ligament reconstruction.<br><br>The Pre-Sutured Tendon is for single patient use only. | | | | | | | | | | | | | | Comparison of<br>Technological<br>Characteristics<br>with the Predicate<br>Device | The subject and predicate devices are based on the following same<br>technological characteristics and both function as constructs for anterior<br>cruciate ligament and posterior cruciate ligament reconstruction.<br><br>The subject device is composed of donated human nonbone tendon pre-<br>sutured with sterile Ultra-high-molecular-weight polyethylene (UHMWPE) | | | | | | | | | | | | | {5}------------------------------------------------ Image /page/4/Picture/1 description: The image shows the logo for RTI Surgical. The logo consists of the letters "rti" in a blue rounded square, followed by the word "surgical" in gray. The "i" in "rti" has a small green dot above it. | Sterilization Process (The BioCleanse Process). Donors meet eligibility<br>requirements for all communicable diseases via a medical doctor review of<br>donor medical and social history and all applicable infectious disease screening<br>tests. The donor blood samples taken at the time of recovery were tested by a<br>facility that is CLIA certified and registered with the FDA. The blood samples<br>are screened for the following: HIV-1 / HIV-2 Antibody, Hepatitis C Virus<br>Antibody, Hepatitis B Surface Antigen, Hepatitis B Core Antibody (Total),<br>Treponema pallidum (Syphilis), Human T-Cell, Lymphotropic Virus I/II<br>Antibody, and HIV-1/HCV/ HBV* NAT-TMA. The donor tissue utilized<br>meets the requirements of the American Association of Tissue Banks (AATB).<br>All infectious disease test results passed acceptability for screening. The Pre-<br>Sutured Tendon has been determined to be suitable for implantation.<br><br>There are no technological differences between the subject and predicate<br>device. However, there are minor dimensional differences between the subject<br>device and the predicate devices. These differences do not affect the intended<br>use, performance, safety, design or function of the subject device for its<br>intended use in anterior cruciate ligament and posterior cruciate ligament<br>reconstruction. | | |---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Performance<br>Data | Visual characteristics and bench testing such as Ultimate Load, Cyclic<br>Displacement, and Suture Pull Out Testing of the Pre-Sutured Tendons were<br>evaluated and are found to meet requirements that are clinically relevant.<br>Non-clinical testing data submitted to demonstrate substantial equivalence<br>includes packaging validation, tissue sterilization and viral inactivation, shelf-<br>life, and biocompatibility. Biocompatibility testing was conducted using<br>methods described in ISO 10993. Bacterial endotoxin testing was also<br>performed and was substantially equivalent to the predicates.<br><br>A human cadaver study was conducted to demonstrate the feasibility of using<br>the Pre-Sutured Tendon for ACL/PCL reconstruction. The results of this end<br>user validation establish that the Pre-Sutured Tendon implants labeling,<br>packaging, dimensions (form), configuration (single/quadruple strand), and<br>functionality meet user needs and expectations. Additionally, the results<br>establish that the single and quadruple strand Pre-Sutured Tendon constructs<br>met the intended use and therefore are appropriate for ACL and PCL<br>reconstruction. The study also concluded that the subject device, the Pre-<br>Sutured Tendon, constructs can be implanted using traditional clinical methods<br>by an orthopedic surgeon. | | Substantial<br>Equivalence | The subject device was demonstrated to be substantially equivalent to the<br>predicate devices cited above with respect to indications for use, aseptic<br>processing, design, size, materials, function, storage, and performance. | | Conclusion | The Pre-Sutured Tendon is substantially equivalent to the predicate devices<br>with respect to indications for use, tissue sterilization processes, aseptic<br>packaging, design, function, materials, and performance. Product safety and<br>performance are adequately supported by the substantial equivalence<br>information and test results. |
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...