Browse hierarchy: [General, Plastic Surgery (SU)](/submissions/SU) → [Subpart E — Surgical Devices](/submissions/SU/subpart-e%E2%80%94surgical-devices) → [21 CFR 878.4040](/submissions/SU/subpart-e%E2%80%94surgical-devices/878.4040) → FXY — Hood, Surgical

# FXY · Hood, Surgical

_General, Plastic Surgery · 21 CFR 878.4040 · Class 2_

**Canonical URL:** https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/FXY

## Overview

- **Product Code:** FXY
- **Device Name:** Hood, Surgical
- **Regulation:** [21 CFR 878.4040](/submissions/SU/subpart-e%E2%80%94surgical-devices/878.4040)
- **Device Class:** 2
- **Review Panel:** [General, Plastic Surgery](/submissions/SU)
- **3rd-party reviewable:** yes

## Identification

Surgical apparel are devices that are intended to be worn by operating room personnel during surgical procedures to protect both the surgical patient and the operating room personnel from transfer of microorganisms, body fluids, and particulate material. Examples include surgical caps, hoods, masks, gowns, operating room shoes and shoe covers, and isolation masks and gowns. Surgical suits and dresses, commonly known as scrub suits, are excluded.

## Classification Rationale

Class II (special controls) for surgical gowns and surgical masks. A surgical N95 respirator or N95 filtering facepiece respirator is not exempt if it is intended to prevent specific diseases or infections, or it is labeled or otherwise represented as filtering surgical smoke or plumes, filtering specific amounts of viruses or bacteria, reducing the amount of and/or killing viruses, bacteria, or fungi, or affecting allergenicity, or it contains coating technologies unrelated to filtration (e.g., to reduce and or kill microorganisms). Surgical N95 respirators and N95 filtering facepiece respirators are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 878.9, and the following conditions for exemption: (i) The user contacting components of the device must be demonstrated to be biocompatible. (ii) Analysis and nonclinical testing must: (A) Characterize flammability and be demonstrated to be appropriate for the intended environment of use; and (B) Demonstrate the ability of the device to resist penetration by fluids, such as blood and body fluids, at a velocity consistent with the intended use of the device. (iii) NIOSH approved under its regulation. (2) Class I (general controls) for surgical apparel other than surgical gowns and surgical masks. The class I device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 878.9.

## Special Controls

*Classification.* (1) Class II (special controls) for surgical gowns and surgical masks. A surgical N95 respirator or N95 filtering facepiece respirator is not exempt if it is intended to prevent specific diseases or infections, or it is labeled or otherwise represented as filtering surgical smoke or plumes, filtering specific amounts of viruses or bacteria, reducing the amount of and/or killing viruses, bacteria, or fungi, or affecting allergenicity, or it contains coating technologies unrelated to filtration (e.g., to reduce and or kill microorganisms). Surgical N95 respirators and N95 filtering facepiece respirators are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 878.9, and the following conditions for exemption:(i) The user contacting components of the device must be demonstrated to be biocompatible.
(ii) Analysis and nonclinical testing must:
(A) Characterize flammability and be demonstrated to be appropriate for the intended environment of use; and
(B) Demonstrate the ability of the device to resist penetration by fluids, such as blood and body fluids, at a velocity consistent with the intended use of the device.
(iii) NIOSH approved under its regulation.
(2) Class I (general controls) for surgical apparel other than surgical gowns and surgical masks. The class I device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 878.9.

## Recent Cleared Devices (13 of 13)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K222214](https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/FXY/K222214.md) | ViVi® Surgical Helmet System (ViVi® Helmet, ViVi® Helmet HPL, ViVi® Hood) | Thi Total Healthcare Innovation GmbH | Oct 17, 2023 | SESE |
| [K200493](https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/FXY/K200493.md) | Stryker T7 Surgical Hoods, Stryker T7 Surgical Togas, Zippered, Stryker T7 Surgical Togas, Zippered with Peel Away Face Shield, Stryker T7 Surgical Togas, Pullover | Stryker Corporation | Mar 21, 2020 | SESE |
| [K140588](https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/FXY/K140588.md) | FLYTE HYBRID HOOD, FLYTE HYBRID HOOD WITH PEELAWAY LENS | Stryker Corporation | Jun 26, 2014 | SESE |
| [K904969](https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/FXY/K904969.md) | HOOD, OPERATING, SURGICAL | Chicago Assoc. For Retarded Citizens | Dec 12, 1990 | SESE |
| [K904276](https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/FXY/K904276.md) | DISPOSABLE BEARD COVER | Anago, Inc. | Nov 21, 1990 | SESE |
| [K903533](https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/FXY/K903533.md) | STERI-SHIELD | Biomedical Devices, Inc. | Oct 19, 1990 | SESE |
| [K902677](https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/FXY/K902677.md) | STERI-SHIELD | Biomedical Devices, Inc. | Aug 17, 1990 | SESE |
| [K880431](https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/FXY/K880431.md) | CARETEX SURGEON'S HOODS | James River Corp. | Feb 24, 1988 | SESE |
| [K770261](https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/FXY/K770261.md) | HOOD, CLARION SURGEONS | Sherwood Medical Industries | Mar 1, 1977 | SESE |
| [K770257](https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/FXY/K770257.md) | HOOD & BEARD COVER, CLARION SURGEON'S | Sherwood Medical Industries | Feb 25, 1977 | SESE |
| [K761070](https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/FXY/K761070.md) | P.S.M. SURGICAL HOOD | The Owenby Co. | Dec 30, 1976 | SESE |
| [K760865](https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/FXY/K760865.md) | BARRIER FASHION BONNET | Surgikos, Inc. | Nov 3, 1976 | SESE |
| [K760855](https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/FXY/K760855.md) | BARRIER SURGICAL HOOD | Surgikos, Inc. | Nov 3, 1976 | SESE |

## Top Applicants

- Biomedical Devices, Inc. — 2 clearances
- Sherwood Medical Industries — 2 clearances
- Stryker Corporation — 2 clearances
- Surgikos, Inc. — 2 clearances
- Anago, Inc. — 1 clearance

---

**Source:** [https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/FXY](https://fda.innolitics.com/submissions/SU/subpart-e%E2%80%94surgical-devices/FXY)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
