MINI LAP RETRACTORS

K093449 · Mini Lap Technologies, Inc. · GCJ · Feb 12, 2010 · Gastroenterology, Urology

Device Facts

Record IDK093449
Device NameMINI LAP RETRACTORS
ApplicantMini Lap Technologies, Inc.
Product CodeGCJ · Gastroenterology, Urology
Decision DateFeb 12, 2010
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 876.1500
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The MINI LAP Instruments are a family of minimally invasive devices with the means to penetrate soft tissue to access certain areas of the human anatomy. The devices are used to manipulate other soft internal tissues.

Device Story

MINI LAP Retractors are minimally invasive surgical instruments designed to penetrate soft tissue and manipulate internal soft tissues. The device consists of a needle-based system; the physician inserts the needle through soft tissue under visualization. Upon advancement, the instrument jaws deploy from the needle. A self-activating safety mechanism prevents the jaws from retracting while in use, serving as a blunt shield for the sharp needle tip. The device is used to hold pneumoperitoneum during procedures. It is a sterile, single-patient-use disposable device. The physician operates the device manually via a handle. The output is the physical retraction or manipulation of internal tissues, aiding the surgeon in visualizing or accessing surgical sites. Benefits include minimally invasive access and tissue management during laparoscopic procedures.

Clinical Evidence

Bench testing only. No clinical data provided.

Technological Characteristics

Manual surgical instrument; sterile, single-patient-use disposable. Configurations include 250mm length with fan or rake clamp types. Features a needle-based delivery system with self-activating safety mechanism to shield needle tip. Constructed of biocompatible materials.

Indications for Use

Indicated for use in patients requiring minimally invasive access to soft tissue and manipulation of internal soft tissues during surgical procedures.

Regulatory Classification

Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

In combination with the general controls of the FD&C Act, the integrated operating table-electromechanical surgical system is subject to the following special controls: 1. (1) Premarket clinical performance testing, or a combination of premarket clinical performance testing and postmarket surveillance (in accordance with special control (2)), must include the following: 1. (i) Objective performance measures (e.g., rate and number of conversions to other surgical modalities, rate of device related adverse events (including tissue injury, hematoma, and increased blood loss), and their severity, cause, and outcomes) must be reported with relevant descriptive comparator performance measures. 2. (ii) The data must demonstrate the performance of the device for providing accurate and precise control of attached surgical instruments in range of clinical conditions relevant to the device's intended use. 3. (iii) The test dataset must include data collected from a patient population representative of the intended patient population under anticipated conditions of use. 2. (2) Data obtained from postmarket surveillance must demonstrate, in consideration of the premarket data obtained in accordance with special control (1), that the device performs in accordance with special control (1), unless FDA determines, based on the totality of the premarket data, that data from postmarket surveillance is not required to demonstrate that the device performs as intended. Such postmarket surveillance must be conducted per a protocol determined appropriate by FDA to demonstrate that the device performs as intended (in consideration of the premarket data obtained in accordance with special control (1)), and must include initiation, enrollment, and reporting requirements to ensure timely periodic updates to FDA on post-market surveillance progress and outcomes. 3. (3) Animal performance testing must evaluate the extent of port site trauma due to repositioning of table during surgical procedures when utilizing robotic minimally invasive and laparoscopic approaches 4. (4) The device manufacturer must develop, and update as necessary, a device-specific use training program that ensures proper device setup/use/shutdown, accurate control of instruments to perform the intended surgical procedures, troubleshooting and handling during unexpected events or emergencies, and safe practices to mitigate use error. 5. (5) The device manufacturer may only distribute the device to facilities that implement and maintain the device-specific use training program and ensure that users of the device have completed the device-specific use training program. (6) Human factors assessment must demonstrate that the user can correctly use the device system across all intended use environments with the provided instructions and training materials, including patient access during normal operating conditions and emergency situations, and effects arising from the integrated nature of the operating table and robotic surgical arms. (7) Labeling must include: (i) A detailed summary of clinical performance testing conducted with the device, including study population, results, adverse events, and comparisons to any comparator groups identified; (ii) A statement in the labeling that the safety and effectiveness for the representative specific procedures was based on evaluation of the device as a surgical tool and did not include evaluation of outcomes related to the treatment of the patient's underlying disease or condition, unless FDA determines that it can be removed or modified based on clinical performance data submitted to FDA; (iii) Identification of compatible devices; (iv) The list of surgical procedures for which the device has been determined to be safe with clinical justification; (v) Reprocessing instructions for reusable components; (vi) A shelf life for any sterile components; (vii) A description of the device-specific use training program; (viii) A statement that the device is only for distribution to facilities that implement and maintain the device-specific use training program and ensure that users of the device have completed the device-specific use training program; and (ix) A summary of any completed postmarket surveillance data collected as required by special control (2), including updated labeling to accurately reflect outcomes observed in postmarket surveillance. (8) Non-clinical performance testing must demonstrate that the device performs as intended under anticipated conditions of use and must include: (i) Device motion accuracy and repeatability; (ii) System testing; (iii) Instrument reliability; (iv) Crosstalk; (v) Table motion control; (vi) Thermal effects on tissue; (vii) User-device interface performance; (viii) Workspace access testing; and (ix) Performance testing with compatible devices. (9) Software verification, validation, and hazard analysis must be performed. (10) Electromagnetic compatibility and electrical, thermal, and mechanical safety testing must be performed. (11) Performance data must demonstrate the sterility of all patient-contacting device components. (12) Performance data must support the shelf life of the device components provided sterile by demonstrating continued sterility and package integrity over the labeled shelf life. (13) Performance data must validate the reprocessing instructions for the reusable components of the device. (14) Performance data must demonstrate that all patient-contacting components of the device are biocompatible. (15) Performance data must demonstrate that all patient-contacting components of the device are non-pyrogenic. (16) The device manufacturer must submit a report to the FDA annually on the anniversary of initial marketing authorization for the device, until such time as FDA may terminate such reporting, which comprises the following information: (i) Cumulative summary, by year, of complaints and adverse events since date of initial marketing authorization; and (ii) Identification and rationale for changes made to the device, labeling, or device specific use training program, which did not require submission of a premarket notification during the reporting period.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K093449 FEB 1 2 2010 Image /page/0/Picture/2 description: The image contains the logo of Mini Lap Technologies Inc. with a stylized atom graphic. Below the logo, the text "510 (k) Summary" is present, with the phrase "510 (k)" underlined. The text is in a clear, sans-serif font and appears to be part of a document or presentation. Submission Type: Special 510(k) Date Prepared [21 CFR 807.92(a)(1)] 2007.92 (a) 2000 November 2, 2009 Submitter's Information [21 CFR 807.92(a)(1)] Regulatory Contact Joseph Azary Orchid Design Oreman Technology Center Shelton, CT 06484 Tel: (203) 922-0105 Fax: (203) 922-0130 Fax: (203) 922-0150 Email: joseph.azary(@orchil-orthopedics.com Sponsor / Manufacturer Sponio Lap Technologies Inc. 88 Ashford Avenue 88 Asinorava vy 10522 FDA Establishment Registration is 3007123990 Tel: 914 591 8400 {1}------------------------------------------------ # Trade Name, Common Name, Classification [21 CFR 807.92(a)(2)] Trade Name - MINI LAP Retractors o Device Common, Usual, or Classification Names - Laparoscopic Instruments, Retractors, Cannula, Trocar, Manual Surgical Instruments o Classification Panel - Classification of this device would fall under the responsibility of the Gastroenterology / Urology o panel. #### Class Based on our research we believe the device is a class 2 device classified under the following Product Codes: - KOG, 21 CFR 876.1500, Endoscope Accessories o - KOA, 21 CFR 876.4730 Manual Surgical Instruments o - FBQ, 21 CFR 878.5090 Trocar o #### Predicate Device [21 CFR 807.92(a)(3)] Mini Lap Instruments - K070686 o ## Description of the Device [21 CFR 807.92(a)(4)] The MINI LAP Instruments are a family of minimally invasive devices. The devices penetrate soft tis-The NHT DFL mounterial areas of the human anatomy. The devices are used to manipulate other soft internal tissues. Prior to insertion, the physician must depress the safety button and retract the instrument into the needle. The needle is inserted through the soft tissue under visualization. Once the needle has penetrated the soft tissue, the physician will advance the instrument into the body cavity using the handle. As the instrument advances, the jaws of the instrument will open. The device includes a self-activating safety that prohibits the jaws from returning to their fully retracted position while in use, which acts as a blunt shield for the sharp needle tip. {2}------------------------------------------------ The device is provided in the following configurations: | Length | Clamp Type | |--------|----------------| | 250mm | Retractor Fan | | 250mm | Retractor Rake | The devices are sterile disposable, single patient only. The devices were designed to hold pneumoperitoneum during use. #### Intended Use [21 CFR 807.92(a)(5)] The MINI LAP Instruments are a family of minimally invasive devices with the means to penetrate soft tissue to access certain areas of the human anatomy. The devices are used to manipulate other soft internal tissues.. ### Technological Characteristics [21 CFR 807.92(a)(6)] We believe the MINI LAP instruments are substantially equivalent to the predicate devices. ### Performance Data [21 CFR 807.92(b)(1)] We believe the addition of these two jaw configurations are a minor expansion to a product family that already has 510(k) clearance. The subject device is composed of biocompatible materials and the sterilization process has been validated. #### Conclusion [21 CFR 807.92(b)(3)] We believe the changes are minor and conclude that the subject devices are as safe and effective as the predicate device. {3}------------------------------------------------ Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a stylized eagle with three stripes forming its body and wing. The eagle is positioned diagonally, facing upwards and to the right. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" is arranged in a circular pattern around the eagle. Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002 Mini Lap Technologies, Inc. % Mr. Joseph Azary 80 Shelton Technology Center Shelton, Connecticut 06484 Re: K093449 Trade/Device Name: Mini Lap Retractors Regulation Number: 21 CFR 876.1500 Regulation Name: Endoscope and accessories Regulatory Class: II Product Code: GCJ Dated: January 7, 2010 Received: January 12, 2010 Dear Mr. Azary: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. FEB 1 2 2010 If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it 11 your device to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Eederal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean r toable of advised that is a receint ation that your device complies with other requirements of the Act or mat For also and regulations administered by other Federal agencies. You must comply with all 1 castle statuivements, including, but not limited to: registration and listing (21 CFR Part 807); lan the Progations and 1); medical device reporting of medical device-related adverse laboring (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems {4}------------------------------------------------ (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRHOffices/ucm115809.html for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/cdrh/mdr/ for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours, Mark N. Melkerson Director Division of Surgical, Orthopedic and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ # Indications for Use 510(k) Number (if known): Device Name: MINI LAP Retractors Indications For Use: The MINI LAP Instruments are a family of minimally invasive devices with the means to penetrate soft tissue to access certain areas of the human anatomy. The devices are used to manipulate other soft internal tissues. Prescription Use × (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) (Division Sign-Off) Division of Surgical, Orthopedic, and Restorative Devices | <strong>Labels</strong> | <strong>Values</strong> | |-------------------------|-------------------------| | 510(k) Number | K093449 | Page 1 of 1
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...