← Product Code [QZB](/submissions/GU/subpart-b%E2%80%94diagnostic-devices/QZB) · K250984

# Maestro System (REF100) (K250984)

_Moon Surgical · QZB · Jun 27, 2025 · Gastroenterology, Urology · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/SU/subpart-b%E2%80%94diagnostic-devices/QZB/K250984

## Device Facts

- **Applicant:** Moon Surgical
- **Product Code:** [QZB](/submissions/GU/subpart-b%E2%80%94diagnostic-devices/QZB.md)
- **Decision Date:** Jun 27, 2025
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 876.1500
- **Device Class:** Class 2
- **Review Panel:** Gastroenterology, Urology
- **Attributes:** AI/ML, PCCP

## Indications for Use

The Maestro System is intended to hold and position laparoscopes and laparoscopic instruments during laparoscopic surgical procedures.

## Device Story

Maestro System is a 2-arm robotic system supporting surgeons during laparoscopic procedures. It utilizes motorized arms to hold and position laparoscopes or instruments. Principle of operation: motors compensate for gravitational force on instruments; surgeon manually maneuvers tools; system maintains position once hand force is removed. Features include 'ScoPilot' for instrument tracking. Input: video feed for instrument detection and tracking; surgeon manual force. Output: robotic arm positioning. Used in OR by surgeons. Connectivity: 5G/WiFi for telemetry and event log offload to cloud. Benefits: reduces surgeon fatigue by maintaining instrument position. System includes user interface for setup, LED status indicators, and redundant encoders for safety. Brakes engage automatically upon fault or power loss.

## Clinical Evidence

Bench testing only. No clinical data. Testing included electrical safety (IEC 60601-1), EMC (IEC 60601-1-2), wireless coexistence (IEEE/ANSI C63.27), and software verification/validation. ScoPilot ML model performance verified using independent video datasets; performance metrics (AP and AR) met predefined specifications including 95% CI lower bounds. Performance testing covered payload, latency, collision detection, and connectivity.

## Technological Characteristics

Electrically actuated 2-arm system. Materials: not specified. Energy: electric motors. Connectivity: 5G/WiFi. Sterilization: EtO for coupling devices. Software: Linux-based (Nvidia Holoscan Yocto v1.0.0) and QNX 7.1.0. ML model for instrument tracking. Safety: redundant encoders, velocity/torque limits, automatic brakes. Dimensions: 151-180cm height, 290kg weight.

## Regulatory Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

## Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

## Predicate Devices

- Maestro System ([K242323](/device/K242323.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

FDA U.S. FOOD &amp; DRUG ADMINISTRATION

June 27, 2025

Moon Surgical
Marion Bruchet
Regulatory Affairs Manager
9 rue d'Enghien
Paris, 75010
France

Re: K250984
Trade/Device Name: Maestro System (REF100)
Regulation Number: 21 CFR 876.1500
Regulation Name: Endoscope And Accessories
Regulatory Class: Class II
Product Code: QZB
Dated: March 31, 2025
Received: March 31, 2025

Dear Marion Bruchet:

We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

FDA's substantial equivalence determination also included the review and clearance of your Predetermined Change Control Plan (PCCP). Under section 515C(b)(1) of the Act, a new premarket notification is not

U.S. Food &amp; Drug Administration
10903 New Hampshire Avenue
Silver Spring, MD 20993
www.fda.gov

{1}

K250984 - Marion Bruchet
Page 2

required for a change to a device cleared under section 510(k) of the Act, if such change is consistent with an established PCCP granted pursuant to section 515C(b)(2) of the Act. Under 21 CFR 807.81(a)(3), a new premarket notification is required if there is a major change or modification in the intended use of a device, or if there is a change or modification in a device that could significantly affect the safety or effectiveness of the device, e.g., a significant change or modification in design, material, chemical composition, energy source, or manufacturing process. Accordingly, if deviations from the established PCCP result in a major change or modification in the intended use of the device, or result in a change or modification in the device that could significantly affect the safety or effectiveness of the device, then a new premarket notification would be required consistent with section 515C(b)(1) of the Act and 21 CFR 807.81(a)(3). Failure to submit such a premarket submission would constitute adulteration and misbranding under sections 501(f)(1)(B) and 502(o) of the Act, respectively.

Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download).

Your device is also subject to, among other requirements, the Quality System (QS) regulation (21 CFR Part 820), which includes, but is not limited to, 21 CFR 820.30, Design controls; 21 CFR 820.90, Nonconforming product; and 21 CFR 820.100, Corrective and preventive action. Please note that regardless of whether a change requires premarket review, the QS regulation requires device manufacturers to review and approve changes to device design and production (21 CFR 820.30 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181).

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050.

All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system.

{2}

K250984 - Marion Bruchet
Page 3

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems.

For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).

Sincerely,

Mark Trumbore -S
Digitally signed by Mark Trumbore
Date: 2025.06.27 07:50:49
-04'00"

Mark Trumbore, Ph.D.
Assistant Director
DHT4A: Division of General Surgery Devices
OHT4: Office of Surgical and Infection Control Devices
Office of Product Evaluation and Quality
Center for Devices and Radiological Health

Enclosure

{3}

FORM FDA 3881 (6/20)
Page 1 of 1
PSC Publishing Services (301) 443-6740
EF

|  DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration Indications for Use | Form Approved: OMB No. 0910-0120 Expiration Date: 06/30/2023 See PRA Statement below.  |
| --- | --- |
|  510(k) Number (if known) K250984  |   |
|  Device Name Maestro System (REF100)  |   |
|  Indications for Use (Describe) The Maestro System is intended to hold and position laparoscopes and laparoscopic instruments during laparoscopic surgical procedures.  |   |
|  Type of Use (Select one or both, as applicable) ☑ Prescription Use (Part 21 CFR 801 Subpart D) ☐ Over-The-Counter Use (21 CFR 801 Subpart C)  |   |
|  CONTINUE ON A SEPARATE PAGE IF NEEDED.  |   |
|  This section applies only to requirements of the Paperwork Reduction Act of 1995. *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*  |   |
|  The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov  |   |
|  "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."  |   |

{4}

MOON SURGICAL

Maestro System – Connectivity – 510(k) submission

June 26th, 2025

# Premarket Notification 510(k) Summary

This summary of 510(k) safety and effectiveness information is submitted in accordance with the requirements of SMDA 1990 and 21 CFR 807.92.

510(k) Number: K250984

Date Prepared: June 26th, 2025

## Applicant Information:

Name: Moon Surgical

Address: 117 Quai de Valmy

75010 Paris France

## Contact Person:

Marion Bruchet

mbruchet@moonsurgical.com

Mobile Number: +33670569899

## Back-up Contact:

Michael A. Daniel

madaniel@clinregconsult.com

## Device Information:

Device Trade Name: Maestro System

Common Name: Maestro System

Classification Name(s): Software Controlled Endoscope and Instrument Holder

Product Code/ Regulation: QZB 21 CFR 876.1500

Classification: Class 2

## Predicate Device: Maestro System (K242323)

## Maestro System Device Description

The Moon Maestro System is a 2-arm system which utilizes software and hardware to provide support to surgeons for manipulating and maintaining instrument position. Motors compensate for gravitational force applied to laparoscopic instruments, while surgeon control is not affected. Conventional laparoscopic tools are exclusively controlled and maneuvered by the surgeon, who grasps the handle of the surgical laparoscopic instrument and moves it freely until the instrument is brought to the desired position. Once surgeon hand force is removed, the Maestro system reverts to maintenance of the specified tool position and instrument tip location.

This 510(k) is being submitted to implement 5G and WiFi capability to the previously cleared Maestro System (K242323). This modification is intended for data offload; only Telemetry and Event logs will be sent over 5G or WiFi. A PCCP is also implemented for the ScoPilot feature.

Moon Surgical

Daniel &amp; Daniel Consulting, LLC

{5}

MOON SURGICAL

Maestro System – Connectivity – 510(k) submission

June 26th, 2025

# Subject Device Intended Use / Indications for Use

The Maestro System is intended to hold and position laparoscopes and laparoscopic instruments during laparoscopic surgical procedures.

# Predicate Device and Subject Device Comparison

The table below compares the Maestro System to the predicate devices.

|  ASPECT | MOON SURGICAL
(Subject Device) | MOON SURGICAL
(Predicate Device) | COMPARISON  |
| --- | --- | --- | --- |
|  Device Name | Maestro System | Maestro System | N/A  |
|  510(k) Number | Not yet assigned | K242323 | N/A  |
|  Product Code / Regulation | QZB / 876.1500
Software Controlled
Endoscope and Instrument Holder | QZB / 876.1500
Software Controlled
Endoscope and Instrument Holder | Identical  |
|  Brief Description | The Moon Surgical Maestro device is an electrically actuated device with movable components intended for laparoscopic surgical procedures to support and position laparoscopic instruments. | Same | Identical  |
|  Intended Use / Indications for Use | The Maestro System is intended to hold and position laparoscopic Instruments during laparoscopic surgical procedures. | Same | Identical  |
|  System basic components | Two motorized Arms that hold and position the laparoscope and/or laparoscopic instruments
Two stages, supporting and positioning the arms
A Control Unit that controls the movements of the arms
Instrument Coupling | Same | Identical  |

Moon Surgical

Daniel &amp; Daniel Consulting, LLC

{6}

MOON SURGICAL

Maestro System – Connectivity – 510(k) submission

June 26th, 2025

|  ASPECT | MOON SURGICAL
(Subject Device) | MOON SURGICAL
(Predicate Device) | COMPARISON  |
| --- | --- | --- | --- |
|   | A User interface for system setup and feature selection |  |   |
|  Method of instrument attachment | Mechanical clamp around laparoscopic instrument and mechanical attachment to arm | Same | Identical  |
|  Mechanisms involved in physical positioning | Electro-mechanical jointed arms driven by internal motors that follow the physician movements. | Same | Identical  |
|  Method of control | Movement of the laparoscope is enabled only upon applied force to the instrument handle. | Same | Identical  |
|  Endoscope Movement | Manual Control
Control algorithm applying motor current for instrument motion triggered by physician’s direct movement
Instrument Based Control
Image processing algorithms that enable the detection of known surgical tools within the displayed video image and when commanded by the surgeon, follow the movement of the chosen tool. | Same | Substantially equivalent – the PCCP in this submission intends to train the model on a new instrument class and on currently known classes (additional or currently known brands)  |
|  Alarm and Warning Condition Indicators | The arms and lighthouse of the Maestro System are equipped with eight LEDs that convey information about the system's status and conditions.
If necessary, alerts, notifications, and fault messages or graphics are displayed on the Touchscreen simultaneously to indicate the system's current status. | Same | Identical  |
|  Single Fault Tolerance | Automatic System
Performance Monitoring in real-time with multiple fault tiers + visual supervision by | Same | Identical  |

Moon Surgical

Daniel &amp; Daniel Consulting, LLC

{7}

MOON SURGICAL

Maestro System – Connectivity – 510(k) submission

June 26th, 2025

|  ASPECT | MOON SURGICAL
(Subject Device) | MOON SURGICAL
(Predicate Device) | COMPARISON  |
| --- | --- | --- | --- |
|   | surgeon via LED indicating system status.
Examples include:
- Redundant encoders on motorized axes
- Velocity, acceleration, current and torque limits
Brakes engage if power is removed |  |   |
|  Back-up fault response | Brakes engage on motorized axis in the event of a fault state to prohibit any arm motion | Same | Identical  |
|  Data storage | Event logs and real-time Telemetry information are stored on the Not-Real-Time PC disk for offline use before being offloaded to the cloud through 5G or Wifi network | Event logs and real-time Telemetry information are stored on the Not-Real-Time PC disk for offline use | Substantially equivalent – the same data is stored but the connectivity feature allows to offload to the cloud through 5G or Wi-fi network  |
|  Maximum Applied Load | 4.4 lbs tested. | Same | Identical  |
|  System dimensions: | Height: 151-180 cm
Width 68 cm
Depth (min) 87-117 cm | Same | Identical  |
|  System weight | 290 kg (640 LBS) | 322 kg (721 LBS) | Substantially equivalent – the change of weight is an ease-of-use improvement, it does not impact the performance or safety of the system  |
|  System OS | Linux based on Nvidia Holoscan Yocto v1.0.0 | Linux based on Nvidia Holoscan Yocto v0.5.1 | Substantially equivalent – the  |

Moon Surgical

Daniel &amp; Daniel Consulting, LLC

{8}

MOON SURGICAL

Maestro System - Connectivity - 510(k) submission

June 26th, 2025

|  ASPECT | MOON SURGICAL
(Subject Device) | MOON SURGICAL
(Predicate Device) | COMPARISON  |
| --- | --- | --- | --- |
|   | QNX 7.1.0 | QNX 7.1.0 | change of Linux OS version is to update its software components to more up-to-date versions. There is no user-facing change between the two Linux OS versions.  |
|  Compatible with | 5mm and 10mm laparoscopes and laparoscopic instruments
5mm and 10mm laparoscopes for ScoPilot | Same | Identical  |
|  Sterilization Method | Ethylene Oxide (EtO) – for coupling devices used to attach laparoscopic instruments | Same | Identical  |
|  Sterility barrier | Drape | Same | Identical  |

# SUMMARY OF NONCLINICAL/BENCH STUDIES

The following non-clinical test were leveraged to demonstrate safety and effectiveness for the subject device's indication for use.

# Electrical safety and electromagnetic compatibility (EMC)

Electrical safety and EMC testing were conducted on the device. The device complies with IEC 60601-1:2005+A1+A2 and IEC 60601-1-6:2010+A1+A2 for safety and the IEC 60601-1-2:2014+A1 for EMC. Wireless immunity and coexistence testing were also conducted on the device. The device complies with AIM 7351731 Rev. 3.00: 20201 for electromagnetic immunity and IEEE/ANSI C63.27:2021 for wireless coexistence.

# Software Verification and Validation Testing

Software verification and validation testing were conducted, and documentation was provided as recommended by FDA's Guidance for Industry and FDA Staff, "Content of Premarket Submissions for Device Software Functions" and "Cybersecurity in Medical Devices: Quality System Considerations and Content of Premarket Submissions". Software testing included testing the software modifications made to implement the new ScoPilot features. This includes detection and tracking of specified instrument tips, generation of motion trajectories, safety limits and detection of malformed inputs at a video and frame level.

Moon Surgical

Daniel &amp; Daniel Consulting, LLC

{9}

MOON SURGICAL

Maestro System – Connectivity – 510(k) submission

June 26th, 2025

# ScoPilot Validation testing

The ML model was trained and tuned through a K-fold cross-tuning process to optimize hyperparameters, until it reached our predefined performance requirements. An independent testing dataset containing videos was used to verify that the model performance (lower bound of the 95%CI for AP and AR) is compliant with our specification when using data including brands unseen during training/tuning.

# Performance Testing

Design verification testing included the following:

- Payload Capacity
- Malformed Input
- Force Accuracy
- Emergency Stop
- Hold Position Accuracy
- IFU Inspection
- Positioning Guidance &amp; Collision Detection
- System Positioning Accuracy
- Bedside Joint Control Accuracy
- End to End Workflow
- Design Inspection
- System Setup
- System Latency
- Electro-Cautery Compatibility
- System Endurance
- Cybersecurity
- System Data Logging
- System Connectivity
- System Cloud Data
- OS
- ScoPilot Motion Performance
- ScoPilot Vision Performance

Design validation testing and usability validation were not performed since the modification is not user-facing, does not add or modify risks, and does impact the clinical safety and performance of the Maestro System (K242323), nor the user interface or user tasks.

# Predetermined Change Control Plan for ScoPilot

The detailed description of the planned modifications, testing methods, validation activities, performance requirements, and communication to users are summarized in the table below:

Moon Surgical

Daniel &amp; Daniel Consulting, LLC

{10}

MOON SURGICAL

Maestro System – Connectivity – 510(k) submission

June 26th, 2025

|  Planned modifications | Test Methods and Validation Activities | Communication to users, as needed  |
| --- | --- | --- |
|  Modification retraining the ML model with the addition of newly acquired data enables it to detect surgical instrument classes already claimed, and an increased variety of other brands in the video feed more accurately. | The verification and validation activities are identical to the previously cleared instrument classes with equivalent performance metrics as outlined in the Modification Protocol. | The labeling will be reviewed and updated as needed, in accordance with the authorized PCCP, to provide users with current information regarding the ScoPilot upgrade.
Users will be notified of the ML model update, by receiving a release note and the new user manual, and by the intervention of a Moon employee to install the new software version  |
|  Modification adding surgical cautery hooks to the ML model class hooks as another surgical instrument class.  |   |   |

## Summary

Based upon the Proposed Modifications outlined in the PCCP, Intended Use, Indications for Use, product technical information, performance evaluation, and standards compliance provided in this premarket notification, the Maestro System has been shown to be substantially equivalent to the cited predicate devices and does not raise questions of safety or effectiveness.

Moon Surgical

Daniel &amp; Daniel Consulting, LLC

---

**Source:** [https://fda.innolitics.com/submissions/SU/subpart-b%E2%80%94diagnostic-devices/QZB/K250984](https://fda.innolitics.com/submissions/SU/subpart-b%E2%80%94diagnostic-devices/QZB/K250984)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
