ODA · Endoscopic Central Control Unit
Gastroenterology, Urology · 21 CFR 876.1500 · Class 2
Overview
| Product Code | ODA |
|---|---|
| Device Name | Endoscopic Central Control Unit |
| Regulation | 21 CFR 876.1500 |
| Device Class | Class 2 |
| Review Panel | Gastroenterology, Urology |
Identification
An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.
Classification Rationale
(1) Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. (2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.
Special Controls
*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.
Recent Cleared Devices (18 of 18)
| Record | Device Name | Applicant | Decision Date | Decision |
|---|---|---|---|---|
| K232406 | KARL STORZ OR1 SCB CONTROL (WU300) | Karl Storz SE & CO. KG | Oct 3, 2023 | SESE |
| K221929 | Smith+Nephew INTELLIO Tablet | Smith+Nephew | Sep 6, 2022 | SESE |
| K203566 | Tablet Application | Smith & Nephew | May 13, 2021 | SESE |
| K192876 | INTELLIO Tablet Application | Smith & Nephew | Feb 27, 2020 | SESE |
| K153205 | IDSS ForceTriad Control Module | Black Diamond Video, Inc. | Aug 1, 2016 | SESE |
| K151282 | core nova Complete Operating Room Endoscopy | Richard Wolf Medical Instruments Corp. | Jan 12, 2016 | SESE |
| K111165 | KARL STORZ SCB / COVIDIEN FORCETRIAD INTERFACE MODULE | KARL STORZ Endoscopy-America, Inc. | Jan 6, 2012 | SESE |
| K102763 | SYSTEMS INTEGRATION | Olympus Medical Systems Corporation | Feb 15, 2011 | SESE |
| K100345 | SYSTEMS INTEGRATION MODEL: ENDOALPHA | Olympus Medical Systems Corporation | Mar 22, 2010 | SESE |
| K083598 | KARL STORZ VOICE1 SCB R-UI SPEECH CONTROL APPLICATION | KARL STORZ Endoscopy-America, Inc. | May 29, 2009 | SESE |
| K080410 | KARL STORZ SCB/CONMED ESU INTERFACE MODULE, MODEL 20091522 | KARL STORZ Endoscopy-America, Inc. | Apr 9, 2008 | SESE |
| K070827 | KARL STORZ SCB INTERFACE CONTROL, MODEL 20090120 | KARL STORZ Endoscopy-America, Inc. | May 22, 2007 | SESE |
| K051613 | MODIFICATION TO OLYMPUS INTEGRATED ENDOSURGERY SYSTEM ENDOALPHA (CONTROL UNIT FOR ENDOSURGERY UCES-2) SOFTWARE VERSION 3 | Olympus Medical Systems Corporation | Aug 15, 2005 | SESE |
| K041912 | SCB/VALLEYLAB FORCE FX INTERFACE UNIT | KARL STORZ Endoscopy-America, Inc. | Oct 25, 2004 | SESE |
| K020255 | RIWO NET OPERATING OPERATING CONTROL SYSTEM, MODEL #5590 | Richard Wolf Medical Instruments Corp. | Sep 18, 2002 | SESE |
| K022270 | MODIFICATION TO OLYMPUS INTEGRATED ENDOSURGERY SYSTEM ENDOALPHA | Olympus Optical Co., Ltd. | Aug 14, 2002 | SESE |
| K994231 | SIEMENS INTEGRATED OPERATING SYSTEM (SIOS) | Siemens Medical Corp. | Aug 10, 2000 | SESE |
| K981993 | OLYMPUS INTEGRATED ENDOSURGERY SYSTEM ENDOALPHA | The Olympus Optical Co. | Aug 21, 1998 | SESE |
Top Applicants
- KARL STORZ Endoscopy-America, Inc. — 5 clearances
- Olympus Medical Systems Corporation — 3 clearances
- Richard Wolf Medical Instruments Corp. — 2 clearances
- Smith & Nephew — 2 clearances
- Black Diamond Video, Inc. — 1 clearance