NAY · System, Surgical, Computer Controlled Instrument

Gastroenterology, Urology · 21 CFR 876.1500 · Class 2

Overview

Product CodeNAY
Device NameSystem, Surgical, Computer Controlled Instrument
Regulation21 CFR 876.1500
Device ClassClass 2
Review PanelGastroenterology, Urology

Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Classification Rationale

(1) Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. (2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Recent Cleared Devices (20 of 162)

Showing 20 most recent of 162 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K253986da Vinci Force Feedback InstrumentsIntuitive Surgical, Inc.Mar 11, 2026SESE
K253556da Vinci SP Surgical System (SP1098); da Vinci E-200 GeneratorIntuitive Surgical, Inc.Jan 16, 2026SESE
K251739da Vinci Surgical System (IS5000)Intuitive Surgical, Inc.Jan 16, 2026SESE
K252675da Vinci SP Surgical System (SP1098)Intuitive Surgical, Inc.Dec 15, 2025SESE
K252069da Vinci SP Surgical System (SP1098)Intuitive Surgical, Inc.Dec 2, 2025SESE
K251426da Vinci SP Surgical System (SP1098)Intuitive Surgical, Inc.Oct 3, 2025SESE
K251817da Vinci SP Surgical System (SP1098)Intuitive Surgical, Inc.Sep 10, 2025SESE
K251227da Vinci Surgical System (IS5000)Intuitive Surgical, Inc.Sep 8, 2025SESE
K251324da Vinci SP Surgical System (SP1098)Intuitive Surgical, Inc.Aug 29, 2025SESE
K252350da Vinci SP Firefly Imaging SystemIntuitive Surgical, Inc.Aug 28, 2025SESE
K250442da Vinci Surgical System, IS5000Intuitive Surgical, Inc.Jul 29, 2025SESE
K251213Da Vinci Surgical System (IS5000)Intuitive Surgical, Inc.Jul 23, 2025SESE
K251202da Vinci Surgical System (IS5000)Intuitive Surgical, Inc.Jul 16, 2025SESE
K250674Vessel Sealer Curved (480522)Intuitive Surgical, Inc.Jun 13, 2025SESE
K240852da Vinci X Surgical System (IS4200); da Vinci Xi Surgical System (IS4000)Intuitive Surgical, Inc.Jun 11, 2025SESE
K250786SP Endoscope, 0° (430600)Intuitive Surgical, Inc.May 13, 2025SESE
K243714da Vinci SP Surgical System (SP1098)Intuitive Surgical, Inc.Apr 24, 2025SESE
K242427da Vinci Xi Surgical System (IS4000); da Vinci X Surgical System (IS4200)Intuitive Surgical, Inc.Apr 1, 2025SESE
K243582da Vinci SP Advanced Access Port Kit (432701)Intuitive Surgical, Inc.Feb 28, 2025SESE
K243641da Vinci Surgical System (IS5000)Intuitive Surgical, Inc.Dec 16, 2024SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...