VARIS PORTALVISION
Device Facts
| Record ID | K955774 |
|---|---|
| Device Name | VARIS PORTALVISION |
| Applicant | Varian Assoc., Inc. |
| Product Code | IYE · Radiology |
| Decision Date | Mar 15, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 892.5050 |
| Device Class | Class 2 |
Indications for Use
To assist the therapist in verification of the treatment field and shielding blocks in relation to anatomical landmarks in radiotherapy treatment.
Device Story
VARiS PortalVision™; on-line electronic portal imaging system for radiotherapy verification. Input: radiation signals via ionization chamber. Processing: image acquisition, processing, and evaluation via VARiS Images application subsystem. Output: verified treatment field images, matched sets, batch matching, scatter plots. Used in clinical radiotherapy settings; operated by therapists. Healthcare providers use quantitative comparison tools to verify shielding blocks and treatment fields against anatomical landmarks; facilitates precise radiation delivery; improves treatment accuracy.
Clinical Evidence
Bench testing only. No clinical data provided.
Technological Characteristics
Ionization chamber imaging sensor. Platform: Intel Pentium-based PC. OS: Microsoft Windows NT or Windows 95. Software: VARiS Images application subsystem. Features: image acquisition, processing, quantitative comparison tools, batch matching, scatter plots, off-line double exposure, multiple combined images, export/import functionality.
Indications for Use
Indicated for use by therapists to verify radiotherapy treatment fields and shielding blocks relative to patient anatomical landmarks.
Regulatory Classification
Identification
A medical charged-particle radiation therapy system is a device that produces by acceleration high energy charged particles (e.g., electrons and protons) intended for use in radiation therapy. This generic type of device may include signal analysis and display equipment, patient and equipment supports, treatment planning computer programs, component parts, and accessories.
Predicate Devices
- Varian Electronic Portal Imaging System 'PortalVision™' (K901932B)
Related Devices
- K080742 — VERISUITE 1.6, VERISUITE-PARTICLE 1.6 · Medcom GmbH · May 9, 2008
- K102237 — PVS MODEL 1.0 · Medcom GmbH · Nov 23, 2010
- K091209 — PORTALVISION ADVANCED IMAGING · Varian Medical Systems, Inc. · Jun 23, 2009
- K181789 — VeriSuite · Medcom GmbH · Sep 21, 2018
- K170058 — TheraView TBI · Cablon Medical B.V. · Mar 3, 2017