PORTPRO ELECTRONIC PORTAL IMAGING SYSTEM
Device Facts
| Record ID | K964485 |
|---|---|
| Device Name | PORTPRO ELECTRONIC PORTAL IMAGING SYSTEM |
| Applicant | Eliav , Ltd. |
| Product Code | IYE · Radiology |
| Decision Date | Feb 4, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 892.5050 |
| Device Class | Class 2 |
Indications for Use
The PORTpro is a free-standing, digital camera based electronic portal imaging device (EPID) for use as an accessory to existing x-radiation therapy systems operating in the megavoltage range (1 - 15 MeV). The PORTpro displays high quality portal images on a computer monitor in virtually real time and also provides archiving and image processing capabilities.
Device Story
Free-standing digital camera-based electronic portal imaging device (EPID); accessory to megavoltage (1-15 MeV) radiation therapy systems. Input: megavoltage x-ray radiation. Transformation: CCD-based digital image acquisition; real-time processing; archiving. Output: high-quality portal images on computer monitor. Used in radiation therapy clinics; operated by physicians and therapy technicians. Benefit: rapid position verification without film development; improved geometric accuracy of field placement; enables non-couch total body (TBI) and total lymphatic irradiation (TLI).
Clinical Evidence
No clinical data provided; bench testing only.
Technological Characteristics
CCD-based digital camera; 746 x 582 acquisition matrix; 16-bit pixel resolution; 1.0 mm spatial resolution. Free-standing support system; 75-inch height; 136 lbs. Operates with megavoltage (1-15 MeV) x-ray systems. No high voltage components.
Indications for Use
Indicated for use as an accessory to megavoltage (1-15 MeV) x-radiation therapy systems to provide real-time portal imaging for patient position verification during radiation therapy.
Regulatory Classification
Identification
A medical charged-particle radiation therapy system is a device that produces by acceleration high energy charged particles (e.g., electrons and protons) intended for use in radiation therapy. This generic type of device may include signal analysis and display equipment, patient and equipment supports, treatment planning computer programs, component parts, and accessories.
Predicate Devices
- SRI 100 Radiotherapy Imaging System (Phillips Medical Systems)
- Huestis Flexi-Holder (Huestis Medical Products)
Related Devices
- K170058 — TheraView TBI · Cablon Medical B.V. · Mar 3, 2017
- K955774 — VARIS PORTALVISION · Varian Assoc., Inc. · Mar 15, 1996
- K981790 — IVIEW ELECTRONIC PORTAL IMAGING DEVICE (EPID) MODEL NUMBER IVEW · Elekta Oncology Systems, Ltd. · Aug 7, 1998
- K971839 — VARIAN RADIATION THERAPY IMAGING SYSTEM · Varian Medical Systems, Inc. · Aug 15, 1997
- K091209 — PORTALVISION ADVANCED IMAGING · Varian Medical Systems, Inc. · Jun 23, 2009