PEACOCK SYSTEM
Device Facts
| Record ID | K963258 |
|---|---|
| Device Name | PEACOCK SYSTEM |
| Applicant | Nomos Corp. |
| Product Code | IYE · Radiology |
| Decision Date | Nov 18, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 892.5050 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
This device is intended to be used as an integrated system for the planning and delivery of dynamic conformal radiation therapy to produce a radiation field which is modulated to conform to the projected tumor volume plus margins by means of a dynamic (moving) multileaf collimator, while simultaneously moving the accelerator gantry.
Device Story
Integrated radiation therapy system; combines CORVUS treatment planning and MIMiC beam-shaping delivery. Input: patient tumor volume data. Operation: CORVUS generates treatment plan; MIMiC multileaf collimator modulates radiation field while accelerator gantry moves. Output: dynamic conformal radiation therapy delivery. Used in clinical radiation oncology settings; operated by radiation oncologists and medical physicists. System enables precise dose delivery to tumor volumes while sparing surrounding healthy tissue.
Clinical Evidence
Physics and clinical testing performed; demonstrated system performs as intended.
Technological Characteristics
Integrated radiation therapy planning and delivery system. Includes CORVUS planning software and MIMiC dynamic multileaf collimator. Operates as accessory to linear accelerator. Class II (21 CFR 892.5050, 21 CFR 892.5710).
Indications for Use
Indicated for patients requiring dynamic conformal radiation therapy to treat tumor volumes via modulated radiation fields.
Regulatory Classification
Identification
A medical charged-particle radiation therapy system is a device that produces by acceleration high energy charged particles (e.g., electrons and protons) intended for use in radiation therapy. This generic type of device may include signal analysis and display equipment, patient and equipment supports, treatment planning computer programs, component parts, and accessories.
Predicate Devices
- Peacock™ Plan (K940663)
- MIMiC™ (K940412)
- Varian Varisource HDR Afterloader (K852842)
- GE Target Planning System (K896353)
- Arc Therapy (K802809)
Related Devices
- K042739 — HI-ART SYSTEM · Tomotherapy Incorporated · Nov 3, 2004
- K013673 — HI-ART SYSTEM · Tomo Therapy, Inc. · Jan 28, 2002
- K060912 — MODIFICATION TO: HI-ART SYSTEM · Tomotherapy Incorporated · Apr 19, 2006
- K151469 — CORVUS Radiation Therapy Planning System · Best Nomos · Nov 25, 2015
- K071938 — MONACO RTP SYSTEM · Computerized Medical Systems, Inc. · Oct 1, 2007