← Product Code [JAK](/submissions/RA/subpart-b%E2%80%94diagnostic-devices/JAK) · K965004 # C.A.R.E. VISION FOR THE SOMATOM PLUS 4 CT SCANNER (K965004) _Siemens Medical Solutions USA, Inc. · JAK · Mar 11, 1997 · Radiology · SESE_ **Canonical URL:** https://fda.innolitics.com/submissions/RA/subpart-b%E2%80%94diagnostic-devices/JAK/K965004 ## Device Facts - **Applicant:** Siemens Medical Solutions USA, Inc. - **Product Code:** [JAK](/submissions/RA/subpart-b%E2%80%94diagnostic-devices/JAK.md) - **Decision Date:** Mar 11, 1997 - **Decision:** SESE - **Submission Type:** Traditional - **Regulation:** 21 CFR 892.1750 - **Device Class:** Class 2 - **Review Panel:** Radiology ## Intended Use The C.A.R.E. VISION is intended to be used for instant display of CT images during interventional procedures using CT scanners. Instant image reconstruction of 3-9 images per second allows the physician to watch the placement of an interventional instrument real time. ## Device Story C.A.R.E. VISION is a software/firmware upgrade for SOMATOM Plus 4 CT scanners; enables real-time CT imaging during interventional procedures. System reconstructs and displays 3-9 images per second; allows physicians to monitor interventional instrument placement in real-time. Operates in clinical settings; integrates with existing CT scan modes; allows switching to standard sequence scanning for enhanced image quality. Benefits include improved visualization of instrument positioning during procedures. ## Clinical Evidence No clinical data provided; substantial equivalence based on technological characteristics and intended use comparison to predicate devices. ## Technological Characteristics Software/firmware upgrade for SOMATOM Plus 4 CT scanner; enables real-time image reconstruction (3-9 images/sec). Operates as an add-on scan mode for existing CT hardware. ## Regulatory Identification A computed tomography x-ray system is a diagnostic x-ray system intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data from the same axial plane taken at different angles. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories. ## Predicate Devices - SOMATOM Plus 4 CT (Siemens Medical Systems, Inc.) - Real Time Reconstruction System Option for Xpress/SX CT System (Toshiba America Medical Systems, Inc.) ## Related Devices - [K983140](/device/K983140.md) — CT BIOPSYVIEW · Philips Medical Systems North America, Inc. · Nov 4, 1998 - [K231482](/device/K231482.md) — uCT ATLAS Astound with uWS-CT-Dual Energy Analysis, uCT ATLAS with uWS-CT-Dual Energy Analysis · Shanghai United Imaging Healthcare Co., Ltd. · Nov 29, 2023 - [K181830](/device/K181830.md) — Azurion R2.0 · Philips Medical Systems Nederland B.V. · Aug 2, 2018 - [K973168](/device/K973168.md) — SMARTVIEW OPTIONS FOR HISPEED CT/I · GE Medical Systems · Nov 21, 1997 - [K162148](/device/K162148.md) — Allura Xper R9 · Philips Medical Systems Nethrlands BV · Nov 23, 2016 ## Submission Summary (Full Text) {0} SIEMENS MAR 11 1997 Appendix 1 K965004 # 510(k) Summary ## C.A.R.E. VISION Option for SOMATOM Plus 4 CT System Submitted by: Siemens Medical Systems, Inc. 186 Wood Avenue South Iselin, NJ 08830 December 13, 1996 This 510(k) summary of safety and effectiveness information is being submitted in accordance with the requirements of SMDA 1990 and 21 CFR §807.92. 1. Contact Person: Ms. Jing Zhang Phone: (908)321-4927 Fax: (908)321-4841 2. Device Name and Classification: Trade Name: C.A.R.E. VISION for the SOMATOM Plus 4 CT Classification Name: Computed Tomography X-ray System Classification Panel: Radiology CFR Section: 21 CFR §892.1750, Class II Device Code: 90JAK 3. Substantial Equivalence: The C.A.R.E. VISION option operating on SOMATOM Plus 4 CT scanner is substantially equivalent to the following devices: 1) SOMATOM Plus 4 CT Siemens Medical Systems, Inc., for scanning 2) Real Time Reconstruction System Option for Xpress/SX CT System Toshiba America Medical Systems, Inc. for real time image reconstruction and display 4. Device Description: The C.A.R.E. VISION option is a new scan mode added to the SOMATOM Plus 4 CT scanner. The option can be installed in the factory or in the field via an upgrade kit consisting of hardware, software and firmware. 510(k) for C.A.R.E. VISION Siemens Medical Systems, Inc. Pg. 21 of 29 {1} # SIEMENS Under C.A.R.E. VISION, three to nine images are reconstructed and displayed per second, effectively simulating a real-time display presentation. More than one C.A.R.E. VISION scans can be set-up and performed one after the other. C.A.R.E. VISION can also be mixed with other scan modes. Switch to SEQUENCE scan mode can be initiated any time during C.A.R.E. VISION thus a particular phase of the operation can be displayed in enhanced image quality. ## 5. Intended Use of the Device: The C.A.R.E. VISION is intended to be used for instant display of CT images during interventional procedures using CT scanners. Instant image reconstruction of 3-9 images per second allows the physician to watch the placement of an interventional instrument real time. ## 6. Summary of Technological Characteristics of the Device Compared to the Predicate Device: The C.A.R.E. Vision has the same technological characteristics as the Real Time Reconstruction System Option for Xpress/SX CT System from Toshiba America Medical Systems, Inc. They both provide real time reconstruction and display of the CT images that can be used in conventional interventional CT exams. ![img-0.jpeg](img-0.jpeg) 510(k) for C.A.R.E. VISION Siemens Medical Systems, Inc. Pg. 22 of 29 --- **Source:** [https://fda.innolitics.com/submissions/RA/subpart-b%E2%80%94diagnostic-devices/JAK/K965004](https://fda.innolitics.com/submissions/RA/subpart-b%E2%80%94diagnostic-devices/JAK/K965004) **Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact). **Cite as:** FDA Device Explorer (Innolitics), https://fda.innolitics.com/submissions/RA/subpart-b%E2%80%94diagnostic-devices/JAK/K965004
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...