SHIMADZU IMAGE AMPLIFIER, MODEL IA-16L/HS

K040870 · Shimadzu Corp. · JAA · May 17, 2004 · Radiology

Device Facts

Record IDK040870
Device NameSHIMADZU IMAGE AMPLIFIER, MODEL IA-16L/HS
ApplicantShimadzu Corp.
Product CodeJAA · Radiology
Decision DateMay 17, 2004
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 892.1650
Device ClassClass 2

Indications for Use

This device is intended to be used in the fluoroscopy and fluorography. This device is operated and used by Physicians and X-ray technologist. The object of this device is total patient population.

Device Story

The Shimadzu Image Amplifier IA-16L/HS is an image-intensified fluoroscopic x-ray system component. It functions as an image intensifier to convert x-ray signals into visible light for real-time imaging. Operated by physicians and x-ray technologists in clinical settings, the device supports diagnostic fluoroscopy and fluorography procedures. It serves as a replacement or upgrade for existing imaging chains, providing visual output for clinical assessment. The device aids in clinical decision-making by enabling visualization of internal structures during interventional or diagnostic procedures, potentially benefiting patients through improved diagnostic accuracy and procedural guidance.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Image-intensified fluoroscopic x-ray system component. Functions as an image intensifier. Class II device (21 CFR 892.1650).

Indications for Use

Indicated for use in fluoroscopy and fluorography for the total patient population. No specific contraindications listed.

Regulatory Classification

Identification

An image-intensified fluoroscopic x-ray system is a device intended to visualize anatomical structures by converting a pattern of x-radiation into a visible image through electronic amplification. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories.

Special Controls

*Classification.* Class II (special controls). An anthrogram tray or radiology dental tray intended for use with an image-intensified fluoroscopic x-ray system only is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 892.9. In addition, when intended as an accessory to the device described in paragraph (a) of this section, the fluoroscopic compression device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 892.9.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" around the perimeter. Inside the circle is a stylized image of three human profiles facing right, stacked on top of each other, with wavy lines below them. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 ## MAY 1 7 2004 Shimadzu Corporation % Mr. Michael Fishback Director, National Service and Regulatory Affairs Shimadzu Medical Systems 20101 South Vermont Avenue TORRANCE CA 90502-1328 Re: K040870 Trade/Device Name: Shimadzu Image Amplifier IA-16L/HS Regulation Number: 21 CFR 892.1650 Regulation Name: Image-intensified fluoroscopic x-ray system Regulatory Class: II Product Code: 90 JAA Dated: March 24, 2004 Received: April 28, 2004 Dear Mr. Fishback: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {1}------------------------------------------------ This letter will allow you to begin marketing your device as described in your Section 510(k) I ms lotter will and in your as FDA finding of substantial equivalence of your device to a legally promaticated predicated." " " results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please 11 you assn office of Compliance at one of the following numbers, based on the regulation number at the top of the letter: | 8xx.1xxx | (301) 594-4591 | |----------------------------------|----------------| | 876.2xxx, 3xxx, 4xxx, 5xxx | (301) 594-4616 | | 884.2xxx, 3xxx, 4xxx, 5xxx, 6xxx | (301) 594-4616 | | 892.2xxx, 3xxx, 4xxx, 5xxx | (301) 594-4654 | | Other | (301) 594-4692 | Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97) you may obtain. Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html. Sincerely yours, Nancy C. Bugden Nancy C. Brogdon Director, Division of Reproductive, Abdominal and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ Page1_of1 510(K) Number (if known): Unknown K040870 IA-16L/HS Device Name Indications For Use: / This device is intended to be used in the fluoroscopy and fluorography. / This device is operated and used by Physicians and X-ray technologist. / The object of this device is total patient population. As mentioned at "Intended Use" in this notification, the intended use of the IA-16L/HS is the same as that of predicate device IA-16LM. Consequently, the indications for use of the IA-16L/HS are also the same as that of the IA-16LM and there are no additional indications. (Please Do Not WRITE BELOW THIS LINE- CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Prescription Use (Per21CFR801.109) OR Over-The-Counter Use Lijndrik Leemans (Division Sign-Off) Division of Reproductive, Abdominal, and Radiological Devices 510(k) Number K040870
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...