QLAB QUANTIFICATION SOFTWARE

K120525 · Philips Healthcare Group · LLZ · Mar 9, 2012 · Radiology

Device Facts

Record IDK120525
Device NameQLAB QUANTIFICATION SOFTWARE
ApplicantPhilips Healthcare Group
Product CodeLLZ · Radiology
Decision DateMar 9, 2012
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 892.2050
Device ClassClass 2
AttributesSoftware as a Medical Device, 3rd-Party Reviewed

Indications for Use

QLAB Quantification Software is a software application package. It is designed to view and quantify image data acquired on Philips Medical Systems ultrasound products.

Device Story

QLAB Quantification software is a software application package for viewing and quantifying ultrasound image data acquired on Philips ultrasound systems. The Cardiac Motion Quantification (CMQ) plug-in provides automated cardiac motion analysis. The software operates on standard PCs, dedicated workstations, or on-board Philips ultrasound systems. It is used by trained healthcare professionals in clinical settings for off-line or on-line study review. Modifications to the CMQ plug-in focus on workflow optimization, specifically reducing the number of user interactions (mouse clicks) and assessment time, while improving reproducibility and consistency of measurements between users. The output assists clinicians in cardiac assessment; the device benefits patients by providing more consistent and efficient quantification of cardiac function.

Clinical Evidence

No clinical data. Bench testing only. Verification and validation testing demonstrated improved workflow (fewer mouse clicks, decreased assessment time) and decreased intra-observer and inter-observer variability compared to the unmodified CMQ software.

Technological Characteristics

Software application package for image processing and quantification. Operates on standard PCs, dedicated workstations, or integrated into Philips ultrasound systems. No specific hardware materials or energy sources defined as it is a software-only modification. Connectivity via standard ultrasound system interfaces. Software-based quantification.

Indications for Use

Indicated for trained healthcare professionals in healthcare facilities/hospitals to view and quantify ultrasound image data acquired on Philips ultrasound systems.

Regulatory Classification

Identification

A medical image management and processing system is a device that provides one or more capabilities relating to the review and digital processing of medical images for the purposes of interpretation by a trained practitioner of disease detection, diagnosis, or patient management. The software components may provide advanced or complex image processing functions for image manipulation, enhancement, or quantification that are intended for use in the interpretation and analysis of medical images. Advanced image manipulation functions may include image segmentation, multimodality image registration, or 3D visualization. Complex quantitative functions may include semi-automated measurements or time-series measurements.

Special Controls

*Classification.* Class II (special controls; voluntary standards—Digital Imaging and Communications in Medicine (DICOM) Std., Joint Photographic Experts Group (JPEG) Std., Society of Motion Picture and Television Engineers (SMPTE) Test Pattern).

Predicate Devices

Reference Devices

Submission Summary (Full Text)

{1}------------------------------------------------ # 2120525 el of 2 MAR - 9 2012 # Special 510(k) Premarket Notification QLAB CMQ Plug-in Modifications #### 510(k) Summary This summary of safety and effectiveness is provided as part of the Premarket Notification in compliance with 21 CFR. Part 807.92. ### 1) Submitter's name, address, telephone number, contact person Philips Ultrasound, Inc. 3000 Minuteman Road Andover, MA 01810-6302 Penny Greco, Regulatory Affairs Specialist Tel: (978) 659-4615 Fax (978) 975-7324 E-mail: penny.greco@philips.com Date prepared: February 15, 2012 2) Name of the device, including the trade or proprietary name if applicable, the common or usual name, and the classification name, if known: Common/Usual Name: Picture Archiving and Communications Systems Workstation Proprietary Name: Classification Name: QLAB CMQ Plug-in CFR 892.2050, system, image processing, radiological, 90 LLZ, Class II #### 3) Substantially Equivalent Devices Philips Ultrasound believes that the modified QLAB CMQ Plug-in is substantially equivalent to the previously cleared OLAB TMQ Plug-in marketed pursuant to K070792, and K042540. Originally marketed as TMQ, the QLAB CMQ Plug-in was documented in a letter to file as described in QLAB 510(k) K110414. 4) Device Description OLAB Quantification software is available either as a stand-alone product that can function on a standard.PC, on board a dedicated workstation, or on-board Philips' ultrasound systems. It can be used by trained healthcare professionals for the on-line and off-line review and quantification of ultrasound studies in healthcare facilities/hospitals. The QLAB Quantification software application package is designed to view and quantify image data acquired on Philips ultrasound products. Cardiac Motion Quantification (CMQ) is a plug-in included in Philips QLAB Quantification software. Page 1 of 2 Philips Ultrasound {2}------------------------------------------------ K120525 Page 2 of 2 #### Special 510(k) Premarket Notification #### QLAB CMO Plug-in Modifications The CMO plug-in is an application within OLAB intended to provide cardiac motion quantification. OLAB Quantification software is intended for use in healthcare facilities/hospitals by trained healthcare professionals. OLAB CMO modifications were implemented to provide clients with improved reproducibility and consistency between users, as well as to provide users with a reduction of workflow steps. The modifications described in this Special 510(k) submission do not alter the intended use of the OLAB Quantification software with the CMO plug-in. #### 5) Indications for Use OLAB Ouantification software is a software application package. It is designed to view and quantify image data acquired on Philips Healthcare ultrasound products. #### 6) Technological characteristics The OLAB Quantification software with the modified CMQ plug-in has the same technological characteristics as the legally marketed device. #### 7) Non-clinical performance data No performance standards for PACS systems or components have been issued under the authority of Section 514. The CMQ modifications were tested in accordance with Philips verification and validation processes. Verification and validation data support the following nonclinical claims for the modified CMQ software relative to the unmodified CMQ software: - Improved workflow fewer mouse clicks for typical assessment; 1. - Improved workflow decreased average time for typical assessment; 2. - 3. Decreased intra-observer variability of assessments; and - Decreased inter-observer variability of assessments. 4. Verification and validation testing concluded that the modified CMQ is safe and effective and introduced no new risks. #### 8) General Safety and Effectiveness Concerns The device labeling contains operating instructions for the safe and effective use of the QLAB Quantification software with the modified CMQ plug-in. #### 9) Conclusions Verification, validation, and testing activities, where required to establish the performance, functionality, and reliability characteristics of the modified device with respect to the predicate were performed. Testing involved system level tests, performance tests, and safety testing from hazard analysis. Testing performed demonstrates that the QLAB Quantification software with modified CMQ plug-in meets all defined reliability requirements and performance claims. Page 2 of 2 Philips Ultrasound {3}------------------------------------------------ # DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Room - WO66-G609 Silver Spring, MD 20993-0002 MAR - 9 2012 Philips Ultrasound, Inc. % Mr. Mark Job Responsible Third Party Regulatory Technology Services LLC 1394 25th Street NW BUFFALO MN 55313 Re: K120525 Trade/Device Name: Philips OLAB Quantification Software Regulation Number: 21 CFR 892.2050 Regulation Name: Picture archiving and communications system Regulatory Class: II Product Code: LLZ Dated: February 21, 2012 Received: February 22, 2012 ## Dear Mr. Job: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate 187 as career in to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into class II (Special Controls), it may be subject to such 11 your de ree to traces in the regulations affecting your device can be found in Title 21, additional controller Elizang (CFR), Parts 800 to 895. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean I lease be determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must or any I outer station of the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801 and 809); medical device reporting (reporting of {4}------------------------------------------------ medical device-related adverse events) (21 CFR 803); and good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820). This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Parts 801 and 809), please contact the Office of In Vitro Diagnostic Device Evaluation and Safety at (301) 796-5450. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely Yours, Janine M. Morris Acting Director Division of Radiological Devices Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ K120525 510(k) Number (if known): Device Name: Philips QLAB Quantification Software Indications for Use: QLAB Quantification Software is a software application package. It is designed to view and quantify image data acquired on Philips Medical Systems ultrasound products. Prescription Use X (Part 21 CFR 801 Subpart D) AND/OR Over-the-counter Use (21 CFR 801 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED) Concurrence of CDRH, Office of In Vitro Diagnostic Devices (OIVD) Mary S. Postel Division Sign-Off Office of In Vitro Diagnostic Device Evaluation and Safety K120525
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...