K072205 · Mercury Computer Systems, Inc. · LLZ · Aug 29, 2007 · Radiology
Device Facts
Record ID
K072205
Device Name
VISAGE PACS/CS, RELEASE VERSION 5.0
Applicant
Mercury Computer Systems, Inc.
Product Code
LLZ · Radiology
Decision Date
Aug 29, 2007
Decision
SESE
Submission Type
Special
Regulation
21 CFR 892.2050
Device Class
Class 2
Attributes
Software as a Medical Device
Indications for Use
Visage PACS is a system for distributing, viewing, and processing medical images and reports within and outside health care environments. It is to be used only by trained and instructed health care professionals. Visage PACS consists of the following components: Visage PACS Storage: Visage PACS Storage offers an archiving option for long-term storage of image data. Visage PACS Web: Data that are stored on the Visage PACS Storage server can be accessed simultaneously by multiple web-based viewing stations within or outside a healthcare enterprise through web clients. Visage CS: Visage CS is a client server system that uses thin client technology for distribution of 3D image data generated from image data of state-of-the-art scanning modalities. Integration with other hospital information systems (HIS, RIS, CIS) is provided via special interfaces. Only DICOM for presentation images can be used on an FDA approved monitor for mammography for primary image diagnosis. Only uncompressed or non-lossy compressed images must be used for primary image diagnosis in mammography.
Device Story
Visage PACS/CS 5.0 is a client-server medical image management system. It ingests DICOM-formatted images from scanning modalities via hospital networks. Visage PACS Storage handles archiving; Visage PACS Web enables browser-based viewing; Visage CS utilizes thin-client technology to stream compressed screen content for 3D visualization without transferring raw DICOM data to the client. Operated by trained healthcare professionals in clinical or remote settings, the system provides tools for image manipulation, measurement, and reporting. New features include cardiac analysis for CT time series, enabling LV segmentation, volume calculation, stroke volume, ejection fraction, and wall motion analysis. These tools assist physicians in clinical decision-making by providing quantitative data derived from cardiac scans. The system supports integration with HIS, RIS, and CIS. Security is maintained via SSL encryption and VPNs for unsecure networks.
Clinical Evidence
Bench testing only. Validation included risk analysis, hazard mitigation, and system/integration testing. No clinical studies were performed. The software development process included requirement tracing and decision reviews to ensure safety and effectiveness.
Technological Characteristics
Stand-alone software package running on general-purpose hardware using Microsoft technology. Employs thin-client architecture for 3D data streaming. Supports DICOM standard for image transfer. Security features include SSL encryption and VPN support. Software is not life-sustaining and does not contact the patient.
Indications for Use
Indicated for trained healthcare professionals to distribute, view, and process medical images and reports within or outside healthcare environments. Supports cardiac CT time series analysis for the left ventricle. Contraindicated for primary mammography diagnosis unless using DICOM presentation images on FDA-approved monitors with uncompressed or non-lossy compressed data.
Regulatory Classification
Identification
A medical image management and processing system is a device that provides one or more capabilities relating to the review and digital processing of medical images for the purposes of interpretation by a trained practitioner of disease detection, diagnosis, or patient management. The software components may provide advanced or complex image processing functions for image manipulation, enhancement, or quantification that are intended for use in the interpretation and analysis of medical images. Advanced image manipulation functions may include image segmentation, multimodality image registration, or 3D visualization. Complex quantitative functions may include semi-automated measurements or time-series measurements.
Special Controls
*Classification.* Class II (special controls; voluntary standards—Digital Imaging and Communications in Medicine (DICOM) Std., Joint Photographic Experts Group (JPEG) Std., Society of Motion Picture and Television Engineers (SMPTE) Test Pattern).
{0}------------------------------------------------
K072205
Mercury Computer Systems, Inc. 199 Riverneck Road Chelmsford, MA 01824-2820
August 22, 2007 United States of America
# E. 510(k) Summary
AUG 2 9 2007
# E.1 Company Identification
Company Contact: Mercury Computer Systems, Inc. 199 Riverneck Road Chelmsford, MA 01824-2820 United States of America Registration No : 3000131217 9040273 Owner/Operator No.:
# E.2 Official Correspondent
| Name/Contact: | David Quimby |
|---------------|---------------------------|
| | 199 Riverneck Road |
| | Chelmsford, MA 01824-2820 |
| | United States of America |
| | Tel.: 978-967-1699 |
| | Fax: 978-256-0588 |
# E.3 Date of Submission
August 22, 2007
# E.4 Device Name
| Trade name: | VISAGE PACS/CS |
|-------------------------|----------------------------------------------------------------------------------------------------------------------------|
| Release Version: | 5.0 |
| Common name: | VISAGE PACS/CS |
| Classification Name: | Picture Archiving and Communications System |
| Reference: | per 21 CFR 892.2050 |
| Class: | II |
| Review Panel: | Radiology |
| Product Classification: | 90 LLZ, Picture Archiving and Communications System |
| Previous 510(k) No.: | K062490 |
| Guidance document: | Guidance for the submission of premarket notifications for<br>medical image management systems (issued on July 27<br>2000) |
# E.5 Substantial Equivalence
The Visage PACS/CS 5.0 Software is substantially equivalent, in the opinion of Mercury Computer Systems Inc., to:
Trade name: AquariusNet Server/Thin client K012086 510(k) No.:
{1}------------------------------------------------
Mercury Computer Systems, Inc. 199 Riverneck Road Chelmsford, MA 01824-2820
August 22, 2007 United States of America
Picture Archiving and Communications System Classification Name: per 21 CFR 892.2050 Reference: Class: II Review Panel: Radiology 90 LLZ, Picture Archiving and Communications System Product Classification: TeraRecon, Inc. Manufacturer: 200 Gregory Lane, Suite C-100 Pleasant Hill, CA 94523-3389 USA
# E.6 Device Description
Visage PACS is a system to distribute, view, and process medical images and reports within and outside of health care environments. It consists of the following components:
- Visage PACS Storage 1
- -Visage PACS Web
- Visage CS -
### Visage PACS Storage
A server receives image data in DICOM format via the hospital network. This provides universal connections to archives, modalities and workstations. The modalities that are supported by Visage PACS Storage are listed in the DICOM Conformance Statement.
Visage PACS Storage offers an archiving option for long-term storage of image data. Only the data consistency on archive media is guaranteed, the system provider has to take own appropriate means (e.g. redundancy) for safety against data loss caused by media destruction. Without the archiving option, the Visage PACS system features no components for long-term data archiving. Additional archiving on film or in digital form is therefore necessary.
### Visage PACS Web
Data that are stored on the Visage PACS Storage server can be accessed simultaneously by multiple web-based viewing stations within a healthcare enterprise or from elsewhere outside through web clients.
The image data transfer is done in DICOM format via the Intranet or the Internet, for example to stations located in a doctor's office, throughout hospitals or a physician's home. Strong data encryption is provided (SSL) to ensure a secure data transfer. Images can be viewed directly within a web browser (Internet Explorer). The system offers simple functions for image manipulation and measurements. Reports can be viewed together with the images on one page.
### Visage CS
Visage CS is a client server system that uses thin client technology for distribution of 3D image data generated from image data of state-of-the-art scanning modalities. The thin client viewer allows to view and process 3D image data. No DICOM data is transferred to the client. It remains on the 3D Application Server at any time, ensuring safe and consistent access to large 3D data throughout the hospital enterprise. Instead of image data, a stream of compressed screen content information is transmitted during interaction.
{2}------------------------------------------------
Mercury Computer Systems, Inc. 199 Riverneck Road Chelmsford, MA 01824-2820
#### August 22, 2007 United States of America
If Visage CS is used in un-secure networks (e.g. WAN) third party VPN (Virtual Private Network) solutions have to be used to secure the data transfer between the Visage Server and the client machines.
### E.6.1 Description of Modification
This is to describe the significant changes associated with the implementation of the cardiac analysis option.
With the new version of the software the user can import cardiac CT time series in order to utilize them for the LV analysis (analysis of the left ventricle).
The LV analysis tool card helps with the analysis of the left ventricle in cardiac
CT time series, which show the heart in various phases of one heart beat. This toolcard quides the user through an LV analysis step by step. After the user has completed the last step the LV Results tool card is displayed as a floating window. The user can review his/her results now and export them to a report.
The LV tools support the physician in finding the left ventricle in the image data. The LV tool card supports the user to find and display the long and short axes of the left ventricle and to segment the left ventricle. It supports the user to calculate the total volume of the left ventricle over one heart cycle, the stroke volume and the ejection fraction of the various LV regions and the accumulated wall motion.
### E.7 Intended Use
Visage PACS is a system for distributing, viewing, and processing medical images and reports within and outside health care environments. It is to be used only by trained and instructed health care professionals. Visage PACS consists of the following components:
Visage PACS Storage: Visage PACS Storage offers an archiving option for long-term storage of image data.
Visage PACS Web: Data that are stored on the Visage PACS Storage server can be accessed simultaneously by multiple web-based viewing stations within or outside a healthcare enterprise through web clients.
Visage CS: Visage CS is a client server system that uses thin client technology for distribution of 3D image data generated from image data of state-ofthe-art scanning modalities.
Integration with other hospital information systems (HIS, RIS, CIS) is provided via special interfaces.
Only DICOM for presentation images can be used on an FDA approved monitor for mammography for primary image diagnosis. Only uncompressed or non-lossy compressed images must be used for primary image diagnosis in mammography.
# E.8 Substantial Equivalence Comparison Chart
Annotation:
{3}------------------------------------------------
Mercury Computer Systems, Inc. 199 Riverneck Road Cheimsford, MA 01824-2820
#
Our Visage product line consists of 2D Web based PACS software and a separate 3D Visage Server and Thin Clients to give the end user a complete 2D/3D PACS experience.
Substantial Equivalence comparison chart regarding the modification:
| | SE-DEVICE | | PREDICATE DEVICES |
|------------------------------------------------------------------------------------------------|-----------------------------------|-----------------------------------|-----------------------------------|
| Product | Visage PACS/CS 5.0 | Visage PACS/CS 4.1 | AquariusNet<br>Server/Thin client |
| Company Name | Mercury Computer<br>Systems, Inc. | Mercury Computer<br>Systems, Inc. | TeraRecon, Inc. |
| 510 (k) number | TBD | K062490 | K012086 |
| New Features in<br>Version 5.0 | | | |
| Cardiac Analysis<br>Option | | | |
| Volume measure-<br>ments | Yes | No | Yes |
| Semi-automatic<br>coronary artery<br>segmentation | Yes | No | Yes |
| Coronary artery<br>navigation and<br>measurement | Yes | No | Yes |
| Functional analysis<br>of the left ventricle<br>(wall motion, ejec-<br>tion fraction) | Yes | No | Yes |
| Additional Fea-<br>tures | | | |
| Vessel segmenta-<br>tion tool with in-<br>creased specificity<br>and improved per-<br>formance | Yes | No | Yes |
| Fusion and side-by-<br>side registration as<br>separate concepts | Yes | No | Yes |
| Pixel probing sup-<br>port in fusion mode | Yes | No | Yes |
| Change of algo-<br>rithm for curved<br>slices | Yes | No | Yes |
| Automatic genera-<br>tion of thick slices | Yes | No | Yes |
| Improved bone<br>removal for CT<br>runoff studies | Yes | No | Yes |
Mercury Computer Systems, Inc.
{4}------------------------------------------------
Mercury Computer Systems, Inc. 199 Riverneck Road Chelmsford, MA 01824-2820
#### August 22, 2007 United States of America
| Product | SE-DEVICE | PREDICATE DEVICES | |
|------------------------------------------------------------------------------|--------------------|--------------------|-----------------------------------|
| | Visage PACS/CS 5.0 | Visage PACS/CS 4.1 | AquariusNet<br>Server/Thin client |
| Changed curved<br>planar reformat<br>(CPR) viewer | Yes | No | Yes |
| Changed lumen<br>view | Yes | No | Yes |
| 4D cardiac CT data<br>support | Yes | No | Yes |
| Coronary artery<br>navigation and<br>measurement | Yes | No | Yes |
| Automatic<br>short/long axis view | Yes | No | Yes |
| Semi-automatic<br>segmentation of left<br>ventricle and coro-<br>nary artery | Yes | No | Yes |
| Functional analysis<br>of left ventricle | Yes | No | Yes |
| Volume measure-<br>ment | Yes | No | Yes |
| Remaining feature as from K062490 see complete table in U.1 | | | |
# E.9 Safety and Effectiveness
### E.9.1 General Safety and Effectiveness Concerns
VISAGE PACS/CS is a medical device that is to be used by trained health care professionals who are responsible for the correct and accurate use of medical images e.g. as a means for providing diagnosis.
The device labeling contains instructions for use and the intended use/indications for use. Warnings, faults etc are explained in the user's manual.
Data that are compressed are properly identified in the image information as being compressed as specified by the DICOM standard. This compression identification remains with the image for the entire life of the image. The correctness of the compression 30 party software is validated by the testing routine for 30 party components during the system/integration test.
# E.9.2 Validation and Effectiveness
The VISAGE PACS/CS 5.0 risk analysis has been performed to identify all potential safety or health hazards during system operation. The hazards are controlled by a risk management plan, including hazard analysis, verification and validation tests (according to our software development process) and evaluations by hospitals.
{5}------------------------------------------------
Mercury Computer Systems, Inc. 199 Riverneck Road Chelmsford, MA 01824-2820
### August 22, 2007 United States of America
According to our risk analysis and risk management there are no software components within the VISAGE PACS/CS 5.0 Software, whose failure or latent design flaw would be expected to result in death or injury to a patient.
Requirement tracing covering specification, design, implementation and verification/validation ensures the fulfillment of all phase requirements, EHR and DMR ensures direct access to all documents.
Integration test plan defines full testing at integration and system testing level. According to this test plan integration and system testing including full testing of hazard mitigation has been performed.
Decision Reviews at the conclusion of each software development phase ensure the fulfillment of the phase results and the validity of the Intended Use and the risk analysis. Testing is an integral part of our Software Design Process.
### E.9.3 Substantial Equivalence
Any differences between the VISAGE PACS/CS 5.0 Software and the substantially equivalent device have no significant influence on safety and effectiveness.
### E.9.4 Technological characteristics
VISAGE PACS/CS is a stand-alone software package used on general purpose hardware, as long as the minimum hardware requirements specified in the manuals are met.
It is based upon standard Microsoft™ technology.
The device does not contact the patient, nor does it control any life sustaining devices.
A physician, providing ample opportunity for competent human interprets images and information delivered by VISAGE PACS/CS.
### E.9.5 Conclusion
We believe that the 510(k) premarket notification contains adequate information and data to enable FDA to determine substantial equivalence to the predicate device.
VISAGE PACS/CS has been and will be manufactured in accordance with the mandatory and voluntary standards listed in this submission.
This submission contains the result of the hazard analysis and all potential hazards have been classified as minor.
Mercury Computer Systems, Inc.
{6}------------------------------------------------
Image /page/6/Picture/11 description: The image shows a circular logo with text around the perimeter and a stylized graphic in the center. The text reads 'Department of Health & Human Services USA' in a circular arrangement. The central graphic consists of three curved lines that appear to represent stylized human figures or flowing water, creating a sense of movement and connection.
# DEPARTMENT OF HEALTH & HUMAN SERVICES
Food and Drug Administration 9200 Corporate Blvd. Rockville MD 20850
Mercury Computer Systems, Inc. c/o Martin Gabler Prosystem AG BEIM STROHHAUSE 27 HAMBURG, GERMANY 20097
AUG 2 9 2007
Re: K072205
VISAGE PACS/CS 5.0 Regulation Number: 21 CFR 892.2050 Regulation Name: Picture archiving and communications system Regulatory Class: II Product Code: LLZ Dated: August 6, 2007 Received: August 8, 2007
Dear Mr. Gabler:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your. device can be found in the Code of Federal Regulations. Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Image /page/6/Picture/10 description: The image shows a logo with the text "FDA Centennial" and the years "1906-2006" in a circular design. The letters "FDA" are prominently displayed in the center of the logo. Below the letters, the word "Centennial" is written in a smaller font. Three stars are arranged beneath the word "Centennial".
{7}------------------------------------------------
Please be advised that FDA's issuance of a substantial equivalence determination does not mean i Nat FDA has made a determination that your device complies with other requirements of the Act that I Drines made a and regulations administered by other Federal agencies. You must or any I with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic forul in and quants bysteins (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) I his letter notification. The FDA finding of substantial equivalence of your device to a legally prematicated predicated in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please if you dosn't spother at one of the following numbers, based on the regulation number at the top of this letter:
| 21 CFR 876.xxx | (Gastroenterology/Renal/Urology) | 240-276-0115 |
|----------------|----------------------------------|--------------|
| 21 CFR 884.xxx | (Obstetrics/Gynecology) | 240-276-0115 |
| 21 CFR 894.xxx | (Radiology) | 240-276-0120 |
| Other | | 240-276-0100 |
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under (21 CF I T at 00 : 77). " roof Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150
or at its Internet address http://www.fda.gov/cdrl/industry/support/index.litml.
Sincerely vours.
Nancy C Hodgon
Nancy C. Brogdon Director, Division of Reproductive, Abdominal, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{8}------------------------------------------------
Mercury Computer Systems, Inc. 199 Riverneck Road Chelmsford, MA 01824-2820
August 22, 2007 United States of America
# D. Statement of Indications for Use
510(k) Number (if known): _ Device Name: VISAGE PACS/CS 5.0 Indications for Use:
Visage PACS is a system for distributing, viewing, and processing medical images and reports within and outside health care environments. It is to be used only by trained and instructed health care professionals. Visage PACS consists of the following components:
Visage PACS Storage: Visage PACS Storage offers an archiving option for long-term storage of image data.
Visage PACS Web: Data that are stored on the Visage PACS Storage server can be accessed simultaneously by multiple web-based viewing stations within or outside a healthcare enterprise through web clients.
Visage CS: Visage CS is a client server system that uses thin client technology for distribution of 3D image data generated from image data of state-of-the-art scanning modalities.
Integration with other hospital information systems (HIS, RIS, CIS) is provided via special interfaces.
Only DICOM for presentation images can be used on an FDA approved monitor for mammography for primary image diagnosis. Only uncompressed or non-lossy compressed images must be used for primary image diagnosis in mammography.
| Prescription Use (Part 21 CFR 801 Subpart D) | X |
|----------------------------------------------|---|
|----------------------------------------------|---|
AND/OR
| Over-The-Counter Use (21 CFR 801 Subpart C) | |
|---------------------------------------------|--|
|---------------------------------------------|--|
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER
PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
JWhang
| (Division Sign-Off) | |
|-----------------------------------------|---------|
| Division of Reproductive, Abdominal and | |
| Radiological Devices | |
| 510(k) Number | K072265 |
Page 1 of 1
Mercury Computer Systems, Inc.
D-1
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Report an issue or suggest a feature
Spot a broken citation, a wrong extraction, a missing document, or something you wish this app did? Tell us — no account needed.
or drag and drop files here
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.