AQUILION ONE VISION, V4.90

K122109 · Toshiba America Medical Systems, In.C · JAK · Sep 21, 2012 · Radiology

Device Facts

Record IDK122109
Device NameAQUILION ONE VISION, V4.90
ApplicantToshiba America Medical Systems, In.C
Product CodeJAK · Radiology
Decision DateSep 21, 2012
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 892.1750
Device ClassClass 2

Indications for Use

This device is indicated to acquire and display cross sectional volumes of the whole body, to include the head, with the capability to image whole organs in a single rotation. Whole organs include but are not limited to brain, heart, pancreas, etc. The Aquilion ONE has the capability to provide volume sets of the entire organ. These volume sets can be used to perform specialized studies, using indicated software/hardware, of the whole organ by a trained and qualified physician.

Device Story

Aquilion ONE Vision is a whole-body CT scanner consisting of a gantry, patient couch, and peripheral cabinets for data processing/display. It captures cross-sectional volume data sets of entire organs (e.g., brain, heart, pancreas) in a single rotation. Operated by trained physicians in clinical settings, the device transforms X-ray attenuation data into cross-sectional images. Modifications from the predicate include increased gantry rotational speed (0.275s), higher X-ray generator power (90kW), and faster image reconstruction (50 images/sec). The system provides volume sets for specialized diagnostic studies. Healthcare providers use these images to visualize internal anatomy, aiding clinical decision-making and diagnosis. Benefits include faster scan times and improved throughput for whole-organ imaging.

Clinical Evidence

No clinical data. Bench testing only, including phantom-based image quality metrics and conformance testing to IEC60601-1 and 21 CFR 1020 standards.

Technological Characteristics

Whole-body CT scanner; 780mm gantry opening; 90kW max generator power; 0.275s gantry rotation speed; Quad Core Xeon-based computer system; 50 images/sec reconstruction speed. Conforms to IEC60601-1 and 21 CFR Subchapter J. Manufacturing per ISO 13485.

Indications for Use

Indicated for whole-body and head cross-sectional volume imaging, including whole-organ imaging in a single rotation, for use by trained and qualified physicians.

Regulatory Classification

Identification

A computed tomography x-ray system is a diagnostic x-ray system intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data from the same axial plane taken at different angles. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K122109 Toshiba America Medical Systems, Inc. 510 (k) Premarket I Aquilion ONE Vision, TSX-301C/1, v4.90 #### 510(k) - SUMMARY OF SAFETY AND EFFECTIVENESS ご - 1. SUBMITTER'S NAME: Toshiba America Medical Systems, Inc. - 2. ADDRESS: 2441 Michelle Drive Tustin, CA. 92780-2068 - 3. ESTABLISHMENT REGISTRATION: 2020563 # 4. CONTACT PERSON: Paul Biggins Director, Regulatory Affairs (714) 730-5000 - 5. Date Prepared: July 12, 2012 - 6. TRADE NAME(S): Aquilion ONE Vision, TSX-301C/1, v4.90 - 7. COMMON NAME: System, X-ray, Computed, Tomography - 8. DEVICE CLASSIFICATION: Class II (per 21 CFR 892.1750) - 9. PRODUCT CODE / DESCRIPTION: JAK - System, Computed Tomography #### 10. PERFORMANCE STANDARD: 21 CFR Subchapter J, Federal Diagnostic X-ray Equipment Standard - 11. PREDICATE DEVICE: Aquilion ONE TSX-301A/2, w/4.74ER K113466 Toshiba America Medical Systems, Inc. ### 12. REASON FOR SUBMISSION: Modification of a cleared device SEP 21 2012 Page 1 of 3 {1}------------------------------------------------ # 13. DEVICE DESCRIPTION: The Aquilion ONE Vision, TSX-301C/1, v4.90 is a whole body CT scanner. This device captures cross sectional volume data sets. The device consists of a gantry, patient couch (table) and peripheral cabinets used for data processing and display. ## 14. SUMMARY OF INTENDED USES: This device is indicated to acquire and display cross sectional volumes of the whole body, to include the head, with the capability to image whole organs in a single rotation. Whole organs include but are not limited to brain, heart, pancreas, etc. The Aquilion ONE has the capability to provide volume sets of the entire organ. These volume sets can be used to perform specialized studies, using indicated software/hardware, of the whole organ by a trained and qualified physician. ### 15. SUBSTANTIAL EQUIVALENCE: This device is substantially equivalent to the Aquilion ONE, TSX-301A/2, w4.74ER, K113466, marketed by Toshiba America Medical Systems. The Aquilion ONE Vision, TSX-301C/1. v4.90, includes modifications to the cleared device which improve the scan time and view rates. The method of operation, base software and manufacturing process remain unchanged from the cleared device. | ltem | Aquilion ONE Vision, TSX-301C/1 | Aquilion ONE TSX-301A/2 | |----------------------------------------------------------|---------------------------------|-------------------------| | Gantry Rotational Speed | 0.275 Seconds | 0.35 Seconds | | View Rate<br>(number of views<br>transferred per second) | 2910 | 2572 | | X-ray Generator Output<br>Power | 90kW Maximum | 70kW Maximum | | X-ray Tube angle | 10 degrees | 11 degrees | | Computer System | Quad Core Xeon based | Dual Core Xeon based | | Image reconstruction<br>(maximum speed) | 50 images per second | 30 images per second | | Gantry Opening | 780mm | 720mm | Summary of Changes from Aquilion ONE TSX-301A/2 - 1. Increased rotational speed from 350mS to 275mS - 2. X-ray Generator is changed to match dose at new speed - 3. Tube has hardware enhancements to allow for higher rotational speed - 4. View rates have been increased Page 2 of 3 {2}------------------------------------------------ #### 16. SAFETY: The device is designed and manufactured under the Quality System Requlations as outlined in 21 CFR § 820 and ISO 13485 Standards. This device is in conformance with the applicable parts of the IEC60601-1 standards and its collateral standards. All requirements of the Federal Diagnostic Equipment Standard, as outlined in 21 CFR §1020, that apply to this device, will be met and reported via product report. ## 17. TESTING Image Quality metrics utilizing phantoms are provided in this submission. Additionally, testing of the modified system was conducted in accordance with the applicable standards published by the International Electrotechnical Commission (IEC) for Medical Devices and CT Systems. #### 18. CONCLUSION The modifications incorporated into the Aquilion ONE Vision, TSX-301C/1, v4.90 do not change the indications for use or the intended use of the device. Safety and effectiveness have been verified via risk management and application of design controls to the modifications. {3}------------------------------------------------ Image /page/3/Picture/0 description: The image is a circular seal for the Department of Health & Human Services - USA. The seal features the department's name in a circular arrangement around the perimeter. In the center of the seal is a stylized eagle or bird-like symbol with three curved lines representing its wings or body. # DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Room - WO66-G609 Silver Spring, MD 20993-0002 Toshiba Medical Systems Corporation % Mr. Paul Biggins Director, Regulatory Affairs Toshiba America Medical Systems, Inc. 2441 Michelle Drive TUSTIN CA 92780 **SEP** 21 2012 Re: K122109 Trade/Device Name: Aquilion ONE Vision, TSX-301c/1, v4.90 Regulation Number: 21 CFR 892.1750 Regulation Name: Computed tomography x-ray system Regulatory Class: II Product Code: JAK Dated: July 16, 2012 Received: July 17, 2012 Dear Mr. Biggins: We have reviewed your Section 510(k) premarket notification of intent to market the device we nave reviewed your becaon 310(x) premains is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate for use stated in the Citiestic) to tegans mannent date of the Medical Device Amendments, or to Conimeres prior to May 20, 1978, the eccordance with the provisions of the Federal Food, DINA de vices mat have occh rechasinou in actre approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The r ou may, dierefore, market the device, boode requirements for annual registration, listing of general controls provisions of the fiel labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into class II (Special Controls), it may be subject to such IT your device is Classified (see above) interest affecting your device can be found in Title 21, additional contors. Existing mayor regulations of the addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean Please be auvised that FDA s issuation of a succession in ther requirements of the Act that FDA has made a determination that your device complies with other requirements of that FDA has made a determination that your as read by other Federal agencies. You must of any Federal statutes and regulations ammitted to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801 and 809); medical device reporting (reporting of {4}------------------------------------------------ medical device-related adverse events) (21 CFR 803); and good manufacturing practice medical device related adverses vrelity systems (QS) regulation (21 CFR Part 820). This letter requirences as set form in the quality of evice as described in your Section 510(k) premarket witi anow you to begin mainential equivalence of your device to a legally marketed nontication. The I Dry intellig of cassion for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Parts 801 and If you desire specific ad rior to: your its a vice Evaluation and Safety at (301) 796-5450. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Tou may obtain of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely Yours, Janine M. Mon Director Division of Radiological Devices Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ # Indications for Use 510(k) Number (if known): Device Name: Aquilion ONE Vision, TSX-301C/1, v4.90 Indications for Use: This device is indicated to acquire and display cross sectional volumes of the whole body, to include the head, with the capability to image whole organs in a single rotation. Whole organs include but are not limited to brain, heart, pancreas, etc. The Aquilion ONE has the capability to provide volume sets of the entire organ. These volume sets can be used to perform specialized studies, using indicated software/hardware, of the whole organ by a trained and qualified physician. Prescription Use X (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of In Vitro Diagnostic Devices (OIVD) --- (Division Sign Off) Division Sian-Off) Division of Radiological Devices Office of In Vitro Diagnostic Device Evaluation and Safety 510(k) Number K122109
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...