← Product Code [IYO](/submissions/RA/subpart-b%E2%80%94diagnostic-devices/IYO) · K182153

# Ultrasound System SONIMAGE HS1 (K182153)

_Konica Minolta, Inc. · IYO · Sep 6, 2018 · Radiology · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/RA/subpart-b%E2%80%94diagnostic-devices/IYO/K182153

## Device Facts

- **Applicant:** Konica Minolta, Inc.
- **Product Code:** [IYO](/submissions/RA/subpart-b%E2%80%94diagnostic-devices/IYO.md)
- **Decision Date:** Sep 6, 2018
- **Decision:** SESE
- **Submission Type:** Special
- **Regulation:** 21 CFR 892.1560
- **Device Class:** Class 2
- **Review Panel:** Radiology
- **Attributes:** Pediatric

## Indications for Use

The Ultrasound System SONIMAGE HS1 and its transducers are products designed to collect ultrasonic image data of the human body for diagnostic purposes. The system employs the ultrasonic pulse-echo method to visualize the anatomic structures, characteristics, and dynamics of the human body, and using an image display, Doppler display and/or Doppler sound, offers a procedure applied to the human body for medical diagnosis or examination. The range of intended clinical applications is same as other conventional ultrasound imaging systems for general purpose, such as small parts, abdomen, obstetrics, gynecology, musculoskeletal (soft tissue), peripheral vascular, and Cardiac.

## Device Story

SONIMAGE HS1 is a diagnostic ultrasound system using pulse-echo technology to visualize human anatomy and dynamics. It processes ultrasonic signals from various transducers to produce B-mode, M-mode, Pulse Wave Doppler (PWD), Continuous Wave Doppler (CWD), Color Doppler, and specialized modes like Elastography and Tissue Doppler Imaging (TDI). Operated by clinicians in clinical settings, the system displays images and Doppler data to assist in medical diagnosis. It supports combined modes (e.g., B+M, B+PWD+Color) for comprehensive assessment. The device aids healthcare providers in visualizing structures and blood flow, facilitating clinical decision-making across multiple specialties including cardiology, obstetrics, and musculoskeletal imaging.

## Clinical Evidence

Bench testing only. No clinical data provided.

## Technological Characteristics

Class II ultrasonic pulsed echo imaging system. Supports multiple transducer types (linear, convex, phased array). Modes: B, M, PWD, CWD, Color Doppler, Elastography, TDI. Connectivity: Standard ultrasound display and processing architecture. Sterilization: Compatible with standard transducer disinfection protocols.

## Regulatory Identification

An ultrasonic pulsed echo imaging system is a device intended to project a pulsed sound beam into body tissue to determine the depth or location of the tissue interfaces and to measure the duration of an acoustic pulse from the transmitter to the tissue interface and back to the receiver. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories.

## Special Controls

*Classification.* Class II (special controls). A biopsy needle guide kit intended for use with an ultrasonic pulsed echo imaging system only is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 892.9.

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Image /page/0/Picture/0 description: The image contains the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health & Human Services logo. To the right of that is the FDA logo, which is a blue square with the letters "FDA" in white. To the right of the blue square is the text "U.S. FOOD & DRUG ADMINISTRATION" in blue.

September 6, 2018

KONICA MINOLTA, Inc. % Mr. Russell Munves Storch Amini PC 140 East 45th Street, 25th floor NEW YORK, NY 10017

Re: K182153

Trade/Device Name: Ultrasound System SONIMAGE HS1 Regulation Number: 21 CFR 892.1560 Regulation Name: Ultrasonic Pulsed Echo Imaging System Regulatory Class: Class II Product Code: IYO, IYN, ITX Dated: August 7, 2018 Received: August 8, 2018

Dear Mr. Munves:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for

{1}------------------------------------------------

devices or postmarketing safety reporting (21 CFR 4. Subpart B) for combination products (see https://www.fda.gov/CombinationProducts/GuidanceRegulatoryInformation/ucm597488.html; good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm.

For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/) and CDRH Learn (http://www.fda.gov/Training/CDRHLearn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (http://www.fda.gov/DICE) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).

Sincerely,

Jeff Bodgea

for Robert A. Ochs. Ph.D. Director Division of Radiological Health Office of In Vitro Diagnostics and Radiological Health Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

### DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration

# Indications for Use

510(k) Number (if known) K182153

Device Name Ultrasound System SONIMAGE HS1

Indications for Use (Describe)

The Ultrasound System SONIMAGE HS1 and its transducers are products designed to collect ultrasonic image data of the human body for diagnostic purposes. The system employs the ultrasonic pulse-echo method to visualize the anatomic structures, characteristics, and dynamics of the human body, and using an image display, Doppler display and/or Doppler sound, offers a procedure applied to the human body for medical diagnosis or examination. The range of intended clinical applications is same as other conventional ultrasound imaging systems for general purpose, such as small parts, abdomen, obstetrics, gynecology, musculoskeletal (soft tissue), peripheral vascular, and Cardiac.

Type of Use (Select one or both, as applicable)

Prescription Use (Part 21 CFR 801 Subpart D)

Over-The-Counter Use (21 CFR 801 Subpart C)

## CONTINUE ON A SEPARATE PAGE IF NEEDED.

This section applies only to requirements of the Paperwork Reduction Act of 1995.

## *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

> Department of Health and Human Services Food and Druq Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

EF

PSC Publishing Services (301) 443-6740

Form Approved: OMB No. 0910-0120 Expiration Date: 06/30/2020 See PRA Statement below.

{3}------------------------------------------------

Transducer:

| Clinical Application        |                                 |   | Mode of Operation |     |     |                  |                       |                     |
|-----------------------------|---------------------------------|---|-------------------|-----|-----|------------------|-----------------------|---------------------|
| General<br>(Track 1 Only)   | Specific<br>(Tracks 1 & 3)      | B | M                 | PWD | CWD | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |
| Ophthalmic                  | Ophthalmic                      |   |                   |     |     |                  |                       |                     |
| Fetal<br>Imaging<br>& Other | Fetal                           | P | P                 | P   |     | P                | Note1                 | Note2               |
|                             | Abdominal                       | P | P                 | P   | P   | P                | Note1                 | Note2,4             |
|                             | Intra-operative (Specify)       |   |                   |     |     |                  |                       |                     |
|                             | Intra-operative (Neuro)         |   |                   |     |     |                  |                       |                     |
|                             | Laparoscopic                    |   |                   |     |     |                  |                       |                     |
|                             | Pediatric                       |   |                   |     |     |                  |                       |                     |
|                             | Small Organ (Note3)             | P | P                 | P   |     | P                | Note1                 | Note2, 5            |
|                             | Neonatal Cephalic               |   |                   |     |     |                  |                       |                     |
|                             | Adult Cephalic                  |   |                   |     |     |                  |                       |                     |
|                             | Trans-rectal                    |   |                   |     |     |                  |                       |                     |
|                             | Trans-vaginal                   | P | P                 | P   |     | P                | Note1                 | Note2               |
|                             | Trans-urethral                  |   |                   |     |     |                  |                       |                     |
|                             | Trans-esoph. (non-Card.)        |   |                   |     |     |                  |                       |                     |
|                             | Musculo-skeletal (Conventional) | P | P                 | P   |     | P                | Note1                 | Note2, 5            |
|                             | Musculo-skeletal (Superficial)  | P | P                 | P   |     | P                | Note1                 | Note2, 5            |
|                             | Intravascular                   |   |                   |     |     |                  |                       |                     |
|                             | Other (Specify)                 |   |                   |     |     |                  |                       |                     |
| Cardiac                     | Cardiac Adult                   | P | P                 | P   | P   | P                | Note1                 | Note2,4             |
|                             | Cardiac Pediatric               | P | P                 | P   | P   | P                | Note1                 | Note2,4             |
|                             | Intravascular (Cardiac)         |   |                   |     |     |                  |                       |                     |
|                             | Trans-esoph. (Cardiac)          |   |                   |     |     |                  |                       |                     |
|                             | Intra-cardiac                   |   |                   |     |     |                  |                       |                     |
|                             | Other (Specify)                 |   |                   |     |     |                  |                       |                     |
| Peripheral<br>Vessel        | Peripheral vessel               | P | P                 | P   |     | P                | Note1                 | Note2, 5            |
|                             | Other (Specify)                 |   |                   |     |     |                  |                       |                     |

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

N = new indication; P = previously cleared by FDA; E = added under this appendix

Note 1: Combined mode BM (B + M), BD (B + Pulse Doppler + M Color Doppler + M Color Doppler) and BcD (B Color Doppler + Pulse Doppler)

Note 2: Other mode Mc (M Color Mode)

Note 3: Small organ includes thyroid and breast

Note 4: Other mode CF-TDI(Color Flow - Tissue Doppler Imaging) and PW-TDI(Pulse Doppler - Tissue Doppler Imaging)

Note 5: Other mode Elastography

{4}------------------------------------------------

Transducer: L18-4

| Clinical Application        |                                 | Mode of Operation |   |     |     |                  |                       |                     |
|-----------------------------|---------------------------------|-------------------|---|-----|-----|------------------|-----------------------|---------------------|
| General<br>(Track 1 Only)   | Specific<br>(Tracks 1 & 3)      | B                 | M | PWD | CWD | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |
| Ophthalmic                  | Ophthalmic                      |                   |   |     |     |                  |                       |                     |
| Fetal<br>Imaging<br>& Other | Fetal                           |                   |   |     |     |                  |                       |                     |
|                             | Abdominal                       |                   |   |     |     |                  |                       |                     |
|                             | Intra-operative (Specify)       |                   |   |     |     |                  |                       |                     |
|                             | Intra-operative (Neuro)         |                   |   |     |     |                  |                       |                     |
|                             | Laparoscopic                    |                   |   |     |     |                  |                       |                     |
|                             | Pediatric                       |                   |   |     |     |                  |                       |                     |
|                             | Small Organ (Note3)             | P                 | P | P   |     | P                | Note1                 | Note2, 4            |
|                             | Neonatal Cephalic               |                   |   |     |     |                  |                       |                     |
|                             | Adult Cephalic                  |                   |   |     |     |                  |                       |                     |
|                             | Trans-rectal                    |                   |   |     |     |                  |                       |                     |
|                             | Trans-vaginal                   |                   |   |     |     |                  |                       |                     |
|                             | Trans-urethral                  |                   |   |     |     |                  |                       |                     |
|                             | Trans-esoph. (non-Card.)        |                   |   |     |     |                  |                       |                     |
|                             | Musculo-skeletal (Conventional) | P                 | P | P   |     | P                | Note1                 | Note2, 4            |
|                             | Musculo-skeletal (Superficial)  | P                 | P | P   |     | P                | Note1                 | Note2, 4            |
|                             | Intravascular                   |                   |   |     |     |                  |                       |                     |
|                             | Other (Specify)                 |                   |   |     |     |                  |                       |                     |
| Cardiac                     | Cardiac Adult                   |                   |   |     |     |                  |                       |                     |
|                             | Cardiac Pediatric               |                   |   |     |     |                  |                       |                     |
|                             | Intravascular (Cardiac)         |                   |   |     |     |                  |                       |                     |
|                             | Trans-esoph. (Cardiac)          |                   |   |     |     |                  |                       |                     |
|                             | Intra-cardiac                   |                   |   |     |     |                  |                       |                     |
|                             | Other (Specify)                 |                   |   |     |     |                  |                       |                     |
| Peripheral<br>Vessel        | Peripheral vessel               | P                 | P | P   |     | P                | Note1                 | Note2, 4            |
|                             | Other (Specify)                 |                   |   |     |     |                  |                       |                     |

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

N = new indication; P = previously cleared by FDA; E = added under this appendix

Note 1: Combined mode BM (B + M), BD (B + Pulse Doppler), BcMc (Color Doppler + M Color Doppler) and BcD (B Color Doppler + Pulse Doppler)

Note 2: Other mode Mc (M Color Mode)

Note 3: Small organ includes thyroid and breast

Note 4: Other mode Elastography

{5}------------------------------------------------

Transducer: C5-2

| Clinical Application        | Mode of Operation               |   |   |     |     |                  |                       |                     |
|-----------------------------|---------------------------------|---|---|-----|-----|------------------|-----------------------|---------------------|
| General<br>(Track 1 Only)   | Specific<br>(Tracks 1 & 3)      | B | M | PWD | CWD | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |
| Ophthalmic                  | Ophthalmic                      |   |   |     |     |                  |                       |                     |
| Fetal<br>Imaging<br>& Other | Fetal                           | P | P | P   |     | P                | Note1                 | Note2               |
|                             | Abdominal                       | P | P | P   |     | P                | Note1                 | Note2               |
|                             | Intra-operative (Specify)       |   |   |     |     |                  |                       |                     |
|                             | Intra-operative (Neuro)         |   |   |     |     |                  |                       |                     |
|                             | Laparoscopic                    |   |   |     |     |                  |                       |                     |
|                             | Pediatric                       |   |   |     |     |                  |                       |                     |
|                             | Small Organ (Specify)           |   |   |     |     |                  |                       |                     |
|                             | Neonatal Cephalic               |   |   |     |     |                  |                       |                     |
|                             | Adult Cephalic                  |   |   |     |     |                  |                       |                     |
|                             | Trans-rectal                    |   |   |     |     |                  |                       |                     |
|                             | Trans-vaginal                   |   |   |     |     |                  |                       |                     |
|                             | Trans-urethral                  |   |   |     |     |                  |                       |                     |
|                             | Trans-esoph. (non-Card.)        |   |   |     |     |                  |                       |                     |
|                             | Musculo-skeletal (Conventional) |   |   |     |     |                  |                       |                     |
|                             | Musculo-skeletal (Superficial)  |   |   |     |     |                  |                       |                     |
|                             | Intravascular                   |   |   |     |     |                  |                       |                     |
|                             | Other (Specify)                 |   |   |     |     |                  |                       |                     |
| Cardiac                     | Cardiac Adult                   |   |   |     |     |                  |                       |                     |
|                             | Cardiac Pediatric               |   |   |     |     |                  |                       |                     |
|                             | Intravascular (Cardiac)         |   |   |     |     |                  |                       |                     |
|                             | Trans-esoph. (Cardiac)          |   |   |     |     |                  |                       |                     |
|                             | Intra-cardiac                   |   |   |     |     |                  |                       |                     |
|                             | Other (Specify)                 |   |   |     |     |                  |                       |                     |
| Peripheral<br>Vessel        | Peripheral vessel               |   |   |     |     |                  |                       |                     |
|                             | Other (Specify)                 |   |   |     |     |                  |                       |                     |

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

N = new indication; P = previously cleared by FDA; E = added under this appendix

Note 1: Combined mode BM (B + M), BD (B + Pulse Doppler), BcMc (Color Doppler + M Color Doppler) and BcD (B Color Doppler + Pulse Doppler)

Note 2: Other mode Mc (M Color Mode)

{6}------------------------------------------------

#### Ultrasound System SONIMAGE HS1 System: Transducer: S4-2

| Clinical Application        |                                 | Mode of Operation |   |     |     |                  |                       |                     |
|-----------------------------|---------------------------------|-------------------|---|-----|-----|------------------|-----------------------|---------------------|
| General<br>(Track 1 Only)   | Specific<br>(Tracks 1 & 3)      | B                 | M | PWD | CWD | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |
| Ophthalmic                  | Ophthalmic                      |                   |   |     |     |                  |                       |                     |
| Fetal<br>Imaging<br>& Other | Fetal                           |                   |   |     |     |                  |                       |                     |
|                             | Abdominal                       | P                 | P | P   | P   | P                | Note1                 | Note2,3             |
|                             | Intra-operative (Specify)       |                   |   |     |     |                  |                       |                     |
|                             | Intra-operative (Neuro)         |                   |   |     |     |                  |                       |                     |
|                             | Laparoscopic                    |                   |   |     |     |                  |                       |                     |
|                             | Pediatric                       |                   |   |     |     |                  |                       |                     |
|                             | Small Organ (Specify)           |                   |   |     |     |                  |                       |                     |
|                             | Neonatal Cephalic               |                   |   |     |     |                  |                       |                     |
|                             | Adult Cephalic                  |                   |   |     |     |                  |                       |                     |
|                             | Trans-rectal                    |                   |   |     |     |                  |                       |                     |
|                             | Trans-vaginal                   |                   |   |     |     |                  |                       |                     |
|                             | Trans-urethral                  |                   |   |     |     |                  |                       |                     |
|                             | Trans-esoph. (non-Card.)        |                   |   |     |     |                  |                       |                     |
|                             | Musculo-skeletal (Conventional) |                   |   |     |     |                  |                       |                     |
|                             | Musculo-skeletal (Superficial)  |                   |   |     |     |                  |                       |                     |
|                             | Intravascular                   |                   |   |     |     |                  |                       |                     |
|                             | Other (Specify)                 |                   |   |     |     |                  |                       |                     |
| Cardiac                     | Cardiac Adult                   | P                 | P | P   | P   | P                | Note1                 | Note2,3             |
|                             | Cardiac Pediatric               | P                 | P | P   | P   | P                | Note1                 | Note2,3             |
|                             | Intravascular (Cardiac)         |                   |   |     |     |                  |                       |                     |
|                             | Trans-esoph. (Cardiac)          |                   |   |     |     |                  |                       |                     |
|                             | Intra-cardiac                   |                   |   |     |     |                  |                       |                     |
|                             | Other (Specify)                 |                   |   |     |     |                  |                       |                     |
| Peripheral<br>Vessel        | Peripheral vessel               |                   |   |     |     |                  |                       |                     |
|                             | Other (Specify)                 |                   |   |     |     |                  |                       |                     |

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

N = new indication; P = previously cleared by FDA; E = added under this appendix

Note 1: Combined mode BM (B + M), BD (B + Pulse Doppler), BcMc (Color Doppler + M Color Doppler) and BcD (B Color Doppler + Pulse Doppler)

Note 2: Other mode Mc (M Color Mode)

Note 3: Other mode CF-TDI(Color Flow - Tissue Doppler Imaging) and PW-TDI(Pulse Doppler - Tissue Doppler Imaging)

{7}------------------------------------------------

Transducer: L14-4

| Clinical Application        |                                 |   |   | Mode of Operation |     |                  |                       |                     |  |  |
|-----------------------------|---------------------------------|---|---|-------------------|-----|------------------|-----------------------|---------------------|--|--|
| General<br>(Track 1 Only)   | Specific<br>(Tracks 1 & 3)      | B | M | PWD               | CWD | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |  |  |
| Ophthalmic                  | Ophthalmic                      |   |   |                   |     |                  |                       |                     |  |  |
| Fetal<br>Imaging<br>& Other | Fetal                           |   |   |                   |     |                  |                       |                     |  |  |
|                             | Abdominal                       |   |   |                   |     |                  |                       |                     |  |  |
|                             | Intra-operative (Specify)       |   |   |                   |     |                  |                       |                     |  |  |
|                             | Intra-operative (Neuro)         |   |   |                   |     |                  |                       |                     |  |  |
|                             | Laparoscopic                    |   |   |                   |     |                  |                       |                     |  |  |
|                             | Pediatric                       |   |   |                   |     |                  |                       |                     |  |  |
|                             | Small Organ (Note3)             | P | P | P                 |     | P                | Note1                 | Note2               |  |  |
|                             | Neonatal Cephalic               |   |   |                   |     |                  |                       |                     |  |  |
|                             | Adult Cephalic                  |   |   |                   |     |                  |                       |                     |  |  |
|                             | Trans-rectal                    |   |   |                   |     |                  |                       |                     |  |  |
|                             | Trans-vaginal                   |   |   |                   |     |                  |                       |                     |  |  |
|                             | Trans-urethral                  |   |   |                   |     |                  |                       |                     |  |  |
|                             | Trans-esoph. (non-Card.)        |   |   |                   |     |                  |                       |                     |  |  |
|                             | Musculo-skeletal (Conventional) | P | P | P                 |     | P                | Note1                 | Note2               |  |  |
|                             | Musculo-skeletal (Superficial)  | P | P | P                 |     | P                | Note1                 | Note2               |  |  |
|                             | Intravascular                   |   |   |                   |     |                  |                       |                     |  |  |
|                             | Other (Specify)                 |   |   |                   |     |                  |                       |                     |  |  |
| Cardiac                     | Cardiac Adult                   |   |   |                   |     |                  |                       |                     |  |  |
|                             | Cardiac Pediatric               |   |   |                   |     |                  |                       |                     |  |  |
|                             | Intravascular (Cardiac)         |   |   |                   |     |                  |                       |                     |  |  |
|                             | Trans-esoph. (Cardiac)          |   |   |                   |     |                  |                       |                     |  |  |
|                             | Intra-cardiac                   |   |   |                   |     |                  |                       |                     |  |  |
|                             | Other (Specify)                 |   |   |                   |     |                  |                       |                     |  |  |
| Peripheral<br>Vessel        | Peripheral vessel               | P | P | P                 |     | P                | Note1                 | Note2               |  |  |
|                             | Other (Specify)                 |   |   |                   |     |                  |                       |                     |  |  |

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

N = new indication; P = previously cleared by FDA; E = added under this appendix

Note 1: Combined mode BM (B + M), BD (B + Pulse Doppler), BcMc (Color Doppler + M Color Doppler) and BcD (B Color Doppler + Pulse Doppler)

Note 2: Other mode Mc (M Color Mode)

Note 3: Small organ includes thyroid and breast

{8}------------------------------------------------

#### Ultrasound System SONIMAGE HS1 System: Transducer: EC9-3

| Clinical Application        |                                 |   |   |     | Mode of Operation |                  |                       |                     |  |
|-----------------------------|---------------------------------|---|---|-----|-------------------|------------------|-----------------------|---------------------|--|
| General<br>(Track 1 Only)   | Specific<br>(Tracks 1 & 3)      | B | M | PWD | CWD               | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |  |
| Ophthalmic                  | Ophthalmic                      |   |   |     |                   |                  |                       |                     |  |
| Fetal<br>Imaging<br>& Other | Fetal                           | P | P | P   |                   | P                | Note1                 | Note2               |  |
|                             | Abdominal                       |   |   |     |                   |                  |                       |                     |  |
|                             | Intra-operative (Specify)       |   |   |     |                   |                  |                       |                     |  |
|                             | Intra-operative (Neuro)         |   |   |     |                   |                  |                       |                     |  |
|                             | Laparoscopic                    |   |   |     |                   |                  |                       |                     |  |
|                             | Pediatric                       |   |   |     |                   |                  |                       |                     |  |
|                             | Small Organ (Specify)           |   |   |     |                   |                  |                       |                     |  |
|                             | Neonatal Cephalic               |   |   |     |                   |                  |                       |                     |  |
|                             | Adult Cephalic                  |   |   |     |                   |                  |                       |                     |  |
|                             | Trans-rectal                    |   |   |     |                   |                  |                       |                     |  |
|                             | Trans-vaginal                   | P | P | P   |                   | P                | Note1                 | Note2               |  |
|                             | Trans-urethral                  |   |   |     |                   |                  |                       |                     |  |
|                             | Trans-esoph. (non-Card.)        |   |   |     |                   |                  |                       |                     |  |
|                             | Musculo-skeletal (Conventional) |   |   |     |                   |                  |                       |                     |  |
|                             | Musculo-skeletal (Superficial)  |   |   |     |                   |                  |                       |                     |  |
|                             | Intravascular                   |   |   |     |                   |                  |                       |                     |  |
|                             | Other (Specify)                 |   |   |     |                   |                  |                       |                     |  |
| Cardiac                     | Cardiac Adult                   |   |   |     |                   |                  |                       |                     |  |
|                             | Cardiac Pediatric               |   |   |     |                   |                  |                       |                     |  |
|                             | Intravascular (Cardiac)         |   |   |     |                   |                  |                       |                     |  |
|                             | Trans-esoph. (Cardiac)          |   |   |     |                   |                  |                       |                     |  |
|                             | Intra-cardiac                   |   |   |     |                   |                  |                       |                     |  |
|                             | Other (Specify)                 |   |   |     |                   |                  |                       |                     |  |
| Peripheral<br>Vessel        | Peripheral vessel               |   |   |     |                   |                  |                       |                     |  |
|                             | Other (Specify)                 |   |   |     |                   |                  |                       |                     |  |

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

N = new indication; P = previously cleared by FDA; E = added under this appendix

Note 1: Combined mode BM (B + M), BD (B + Pulse Doppler), BcMc (Color Doppler + M Color Doppler) and BcD (B Color Doppler + Pulse Doppler)

Note 2: Other mode Mc (M Color Mode)

{9}------------------------------------------------

Transducer: L11-3

| Clinical Application        |                                 | Mode of Operation |   |     |     |                  |                       |                     |
|-----------------------------|---------------------------------|-------------------|---|-----|-----|------------------|-----------------------|---------------------|
| General<br>(Track 1 Only)   | Specific<br>(Tracks 1 & 3)      | B                 | M | PWD | CWD | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |
| Ophthalmic                  | Ophthalmic                      |                   |   |     |     |                  |                       |                     |
| Fetal<br>Imaging<br>& Other | Fetal                           |                   |   |     |     |                  |                       |                     |
|                             | Abdominal                       |                   |   |     |     |                  |                       |                     |
|                             | Intra-operative (Specify)       |                   |   |     |     |                  |                       |                     |
|                             | Intra-operative (Neuro)         |                   |   |     |     |                  |                       |                     |
|                             | Laparoscopic                    |                   |   |     |     |                  |                       |                     |
|                             | Pediatric                       |                   |   |     |     |                  |                       |                     |
|                             | Small Organ (Note3)             | P                 | P | P   |     | P                | Note1                 | Note2, 4            |
|                             | Neonatal Cephalic               |                   |   |     |     |                  |                       |                     |
|                             | Adult Cephalic                  |                   |   |     |     |                  |                       |                     |
|                             | Trans-rectal                    |                   |   |     |     |                  |                       |                     |
|                             | Trans-vaginal                   |                   |   |     |     |                  |                       |                     |
|                             | Trans-urethral                  |                   |   |     |     |                  |                       |                     |
|                             | Trans-esoph. (non-Card.)        |                   |   |     |     |                  |                       |                     |
|                             | Musculo-skeletal (Conventional) | P                 | P | P   |     | P                | Note1                 | Note2, 4            |
|                             | Musculo-skeletal (Superficial)  | P                 | P | P   |     | P                | Note1                 | Note2, 4            |
|                             | Intravascular                   |                   |   |     |     |                  |                       |                     |
|                             | Other (Specify)                 |                   |   |     |     |                  |                       |                     |
| Cardiac                     | Cardiac Adult                   |                   |   |     |     |                  |                       |                     |
|                             | Cardiac Pediatric               |                   |   |     |     |                  |                       |                     |
|                             | Intravascular (Cardiac)         |                   |   |     |     |                  |                       |                     |
|                             | Trans-esoph. (Cardiac)          |                   |   |     |     |                  |                       |                     |
|                             | Intra-cardiac                   |                   |   |     |     |                  |                       |                     |
|                             | Other (Specify)                 |                   |   |     |     |                  |                       |                     |
| Peripheral<br>Vessel        | Peripheral vessel               | P                 | P | P   |     | P                | Note1                 | Note2, 4            |
|                             | Other (Specify)                 |                   |   |     |     |                  |                       |                     |

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

N = new indication; P = previously cleared by FDA; E = added under this appendix

Note 1: Combined mode BM (B + M), BD (B + Pulse Doppler), BcMc (Color Doppler + M Color Doppler) and BcD (B Color Doppler + Pulse Doppler)

Note 2: Other mode Mc (M Color Mode)

Note 3: Small organ includes thyroid and breast

Note 4: Other mode Elastography

{10}------------------------------------------------

#### Ultrasound System SONIMAGE HS1 System: Transducer: MC10-3

| Clinical Application        |                                 | Mode of Operation |   |     |     |                  |                       |                     |
|-----------------------------|---------------------------------|-------------------|---|-----|-----|------------------|-----------------------|---------------------|
| General<br>(Track 1 Only)   | Specific<br>(Tracks 1 & 3)      | B                 | M | PWD | CWD | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |
| Ophthalmic                  | Ophthalmic                      |                   |   |     |     |                  |                       |                     |
| Fetal<br>Imaging<br>& Other | Fetal                           |                   |   |     |     |                  |                       |                     |
|                             | Abdominal                       |                   |   |     |     |                  |                       |                     |
|                             | Intra-operative (Specify)       |                   |   |     |     |                  |                       |                     |
|                             | Intra-operative (Neuro)         |                   |   |     |     |                  |                       |                     |
|                             | Laparoscopic                    |                   |   |     |     |                  |                       |                     |
|                             | Pediatric                       |                   |   |     |     |                  |                       |                     |
|                             | Small Organ (Note3)             | P                 | P | P   |     | P                | Note1                 | Note2               |
|                             | Neonatal Cephalic               |                   |   |     |     |                  |                       |                     |
|                             | Adult Cephalic                  |                   |   |     |     |                  |                       |                     |
|                             | Trans-rectal                    |                   |   |     |     |                  |                       |                     |
|                             | Trans-vaginal                   |                   |   |     |     |                  |                       |                     |
|                             | Trans-urethral                  |                   |   |     |     |                  |                       |                     |
|                             | Trans-esoph. (non-Card.)        |                   |   |     |     |                  |                       |                     |
|                             | Musculo-skeletal (Conventional) | P                 | P | P   |     | P                | Note1                 | Note2               |
|                             | Musculo-skeletal (Superficial)  | P                 | P | P   |     | P                | Note1                 | Note2               |
|                             | Intravascular                   |                   |   |     |     |                  |                       |                     |
|                             | Other (Specify)                 |                   |   |     |     |                  |                       |                     |
| Cardiac                     | Cardiac Adult                   |                   |   |     |     |                  |                       |                     |
|                             | Cardiac Pediatric               |                   |   |     |     |                  |                       |                     |
|                             | Intravascular (Cardiac)         |                   |   |     |     |                  |                       |                     |
|                             | Trans-esoph. (Cardiac)          |                   |   |     |     |                  |                       |                     |
|                             | Intra-cardiac                   |                   |   |     |     |                  |                       |                     |
|                             | Other (Specify)                 |                   |   |     |     |                  |                       |                     |
| Peripheral<br>Vessel        | Peripheral vessel               | P                 | P | P   |     | P                | Note1                 | Note2               |
|                             | Other (Specify)                 |                   |   |     |     |                  |                       |                     |

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

N = new indication; P = previously cleared by FDA; E = added under this appendix

Note 1: Combined mode BM (B + M), BD (B + Pulse Doppler), BcMc (Color Doppler + M Color Doppler) and BcD (B Color Doppler + Pulse Doppler)

Note 2: Other mode Mc (M Color Mode)

Note 3: Small organ includes thyroid and breast

{11}------------------------------------------------

#### Ultrasound System SONIMAGE HS1 System: Transducer: HL18-4

| Clinical Application        |                                 | Mode of Operation |   |     |     |                  |                       |                     |
|-----------------------------|---------------------------------|-------------------|---|-----|-----|------------------|-----------------------|---------------------|
| General<br>(Track 1 Only)   | Specific<br>(Tracks 1 & 3)      | B                 | M | PWD | CWD | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |
| Ophthalmic                  | Ophthalmic                      |                   |   |     |     |                  |                       |                     |
| Fetal<br>Imaging<br>& Other | Fetal                           |                   |   |     |     |                  |                       |                     |
|                             | Abdominal                       |                   |   |     |     |                  |                       |                     |
|                             | Intra-operative (Specify)       |                   |   |     |     |                  |                       |                     |
|                             | Intra-operative (Neuro)         |                   |   |     |     |                  |                       |                     |
|                             | Laparoscopic                    |                   |   |     |     |                  |                       |                     |
|                             | Pediatric                       |                   |   |     |     |                  |                       |                     |
|                             | Small Organ (Note3)             | P                 | P | P   |     | P                | Note1                 | Note2               |
|                             | Neonatal Cephalic               |                   |   |     |     |                  |                       |                     |
|                             | Adult Cephalic                  |                   |   |     |     |                  |                       |                     |
|                             | Trans-rectal                    |                   |   |     |     |                  |                       |                     |
|                             | Trans-vaginal                   |                   |   |     |     |                  |                       |                     |
|                             | Trans-urethral                  |                   |   |     |     |                  |                       |                     |
|                             | Trans-esoph. (non-Card.)        |                   |   |     |     |                  |                       |                     |
|                             | Musculo-skeletal (Conventional) | P                 | P | P   |     | P                | Note1                 | Note2               |
|                             | Musculo-skeletal (Superficial)  | P                 | P | P   |     | P                | Note1                 | Note2               |
|                             | Intravascular                   |                   |   |     |     |                  |                       |                     |
|                             | Other (Specify)                 |                   |   |     |     |                  |                       |                     |
| Cardiac                     | Cardiac Adult                   |                   |   |     |     |                  |                       |                     |
|                             | Cardiac Pediatric               |                   |   |     |     |                  |                       |                     |
|                             | Intravascular (Cardiac)         |                   |   |     |     |                  |                       |                     |
|                             | Trans-esoph. (Cardiac)          |                   |   |     |     |                  |                       |                     |
|                             | Intra-cardiac                   |                   |   |     |     |                  |                       |                     |
|                             | Other (Specify)                 |                   |   |     |     |                  |                       |                     |
| Peripheral<br>Vessel        | Peripheral vessel               |                   |   |     |     |                  |                       |                     |
|                             | Other (Specify)                 |                   |   |     |     |                  |                       |                     |

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

N = new indication; P = previously cleared by FDA; E = added under this appendix

Note 1: Combined mode BM (B + M), BD (B + Pulse Doppler), BcMc (Color Doppler + M Color Doppler) and BcD (B Color Doppler + Pulse Doppler)

Note 2: Other mode Mc (M Color Mode)

Note 3: Small organ includes thyroid and breast

---

**Source:** [https://fda.innolitics.com/submissions/RA/subpart-b%E2%80%94diagnostic-devices/IYO/K182153](https://fda.innolitics.com/submissions/RA/subpart-b%E2%80%94diagnostic-devices/IYO/K182153)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
