← Product Code [IYO](/submissions/RA/subpart-b%E2%80%94diagnostic-devices/IYO) · K072797

# GE LOGIQ I COMAPACT ULTRASOUND, GE LOGIQ E COMPACT ULTRASOUND, GE VIVID E COMPACT ULTRASOUND (K072797)

_General Electric Co. · IYO · Oct 17, 2007 · Radiology · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/RA/subpart-b%E2%80%94diagnostic-devices/IYO/K072797

## Device Facts

- **Applicant:** General Electric Co.
- **Product Code:** [IYO](/submissions/RA/subpart-b%E2%80%94diagnostic-devices/IYO.md)
- **Decision Date:** Oct 17, 2007
- **Decision:** SESE
- **Submission Type:** Special
- **Regulation:** 21 CFR 892.1560
- **Device Class:** Class 2
- **Review Panel:** Radiology
- **Attributes:** Pediatric

## Indications for Use

Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows: Fetal/OB: Abdominal (GYN & Urology); Pediatric; Small Organ (breast, testes, thyroid); Neonatal and Adult Cephalic; Cardiac (adult & pediatric); Peripheral Vascular; Intra-operative (abdominal, thoracic and PV), Musculo-skeletal Conventional, Transrectal and Transvaginal.

## Device Story

GE LOGIQ-i/e & Vivid-e are compact, portable diagnostic ultrasound systems; feature integrated keyboard, LCD display, and interchangeable electronic-array transducers. Device acquires, processes, and displays digital ultrasound data; includes Doppler audio and color GUI. Used by physicians in clinical settings for imaging and fluid flow analysis. System provides enhanced needle visualization and electrical docking carts for flexibility. Output allows real-time visualization of anatomy and blood flow, aiding clinical diagnosis and procedural guidance. Benefits include portability for point-of-care use and improved diagnostic capability via specialized transducers.

## Clinical Evidence

Bench testing only. Evaluated for acoustic output, biocompatibility, cleaning/disinfection, and thermal/electrical/mechanical safety. Conforms to applicable medical device safety standards. No clinical data required.

## Technological Characteristics

Compact portable ultrasound system; electronic-array transducers; integrated LCD and keyboard. Connectivity via electrical docking carts. Software-based digital acquisition and processing. Conforms to 21 CFR 820, ISO 9001, and ISO 13485. Sterilization/disinfection per manufacturer guidelines.

## Regulatory Identification

An ultrasonic pulsed echo imaging system is a device intended to project a pulsed sound beam into body tissue to determine the depth or location of the tissue interfaces and to measure the duration of an acoustic pulse from the transmitter to the tissue interface and back to the receiver. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories.

## Special Controls

*Classification.* Class II (special controls). A biopsy needle guide kit intended for use with an ultrasonic pulsed echo imaging system only is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 892.9.

## Predicate Devices

- GE LOGIQ-ile & Vivid-e Compact Ultrasound ([K050126](/device/K050126.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Special 510(k) Premarket Notification GE LOGIQ-i/e & Vivid-e Compact Ultrasound September 28, 2007

K072797

OCT 17 2007

# Attachment B:

Summary of Safety and Effectiveness Prepared in accordance with 21 CFR Part 807.92(c).

|  | GE Healthcare                                                 |
|--|---------------------------------------------------------------|
|  | General Electric Company<br>P.O. Box 414, Milwaukee, WI 53201 |

Section a):

| 1. Submitter:   | GE Medical Systems, Ultrasound and Primary Care Diagnostics, LLC<br>PO Box 414<br>Milwaukee, WI 53201                                                                                                                                         |
|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Contact Person: | Allen Schuh,<br>Manager, Ultrasound Regulatory Affairs<br>Telephone: 414-721-3992; Fax: 414-721-3899                                                                                                                                          |
| Date Prepared:  | September 25, 2007                                                                                                                                                                                                                            |
| 2. Device Name: | GE LOGIQ-i/e & Vivid-e Compact Ultrasound<br>Ultrasonic Pulsed Doppler Imaging System, 21 CFR 892.1550, 90-IYN<br>Ultrasonic Pulsed Echo Imaging System, 21 CFR 892.1560, 90-IYO<br>Diagnostic Ultrasonic Transducer, 21 CFR 892.1570, 90-ITX |

3. Marketed Device: GE LOGIQ-ile & Vivid-e Compact Ultrasound, 510(k) No: K050126.

4. Device Description: The GE Compact Ultrasound is a very compact and portable diagnostic ultrasound system having three variations: LOGIQ-i, LOGIQ-e and Vivid-e, each with options and features suited for its market niche. It has an integrated keyboard, LCD display and several interchangeable electronic-array transducers with an approximate size of 34 cm wide, 29 cm deep and 6 cm high in transport configuration and provides digital acquisition, processing and display capability. The user interface includes a computer keyboard, an intuitive layout of specialized controls, color GUI display and Doppler audio.

5. Indications for Use: The device is intended for use by a qualified physician for ultrasound evaluation of Fetal/OB: Abdominal (GYN & Urology); Pediatric; Small Organ (breast, testes, thyroid); Neonatal and Adult Cephalic; Cardiac (adult & pediatric); Peripheral Vascular; Intra-operative (abdominal, thoracic and PV), Musculo-skeletal Conventional, Transrectal and Transvaginal.

6. Comparison with Predicate Device: The modified Compact Ultrasound devices are virtually identical having the same design, construction, materials, brand names and intended uses. All technological characteristics and effectiveness features are equivalent. The modified device has additional transducers, enhanced imaging to better visualize invasive needles and electrical docking carts for greater flexibility and ease of use.

#### Section b):

1. Non-clinical Tests: The device has been evaluated for acoustic output, biocompatibility, cleaning and disinfection effectiveness as well as thermal, electrical and mechanical safety, and has been found to conform with applicable medical device safety standards.

2. Clinical Tests: None required.

3. Conclusion: Intended uses and other key features are consistent with traditional clinical practice, FDA guidelines, and established methods of patient examination. The design and development process of the manufacturer conforms with 21 CFR 820, ISO 9001 and 13485 guality systems. The device conforms to applicable medical device safety standards and compliance is verified through independent evaluation by a Nationally Recognized Testing Lab. (NRTL) with ongoing factory surveillance. Diagnostic ultrasound has accumulated a long history of safe and effective performance. Therefore, it is the opinion of GE Healthcare that the GE Compact Ultrasound is substantially equivalent with respect to safely and effectiveness to diagnostic ultrasound devices currently cleared for market.

{1}------------------------------------------------

Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized symbol featuring three abstract shapes that resemble a human figure or a stylized wave pattern.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

# OCT 1 7 2007

Mr. Allen Schuh Manager, Regulatory Affairs GE Medical Systems, Ultrasound and Primary Care Diagnostics, LLC 9900 Innovation Drive WAUWATOSA WI 53226 USA

Re: K072797

Trade/Device Name: GE LOGIQ-i/e & Vivid-e Compact Ultrasound System Regulation Number: 21 CFR 892.1560 Regulation Name: Ultrasonic pulsed echo imaging system Regulatory Class: II Product Code: IYN, IYO, and ITX Dated: September 28, 2007 Received: October 1, 2007

Dear Mr. Schuh:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration,

This determination of substantial equivalence applies to the following transducers intended for use with the GE LOGIQ-i/e & Vivid-e Compact Ultrasound System, as described in your premarket notification:

Transducer Model Number

| 4C-RS  | i12L-RS   |
|--------|-----------|
| 8C-RS  | i/t739-RS |
| E8C-RS | 3S-RS     |
| 8L-RS  | 6S-RS     |
| 9L-RS  | P2D       |
| 12L-RS |           |

{2}------------------------------------------------

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

This determination of substantial equivalence is granted on the condition that prior to shipping the first device, you submit a postclearance special report. This report should contain complete information, including acoustic output measurements based on production line devices, requested in Appendix G. (enclosed) of the Center's September 30, 1997 "Information for Manufacturers Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers." If the special report is incomplete or contains unacceptable values (e.g., acoustic output greater than approved levels), then the 510(k) clearance may not apply to the production units which as a result may be considered adulterated or misbranded.

The special report should reference the manufacturer's 510(k) number. It should be clearly and prominently marked "ADD-TO-FILE" and should be submitted in duplicate to:

> Food and Drug Administration Center for Devices and Radiological Health Document Mail Center (HFZ-401) 9200 Corporate Boulevard Rockville, Maryland 20850

This letter will allow you to begin marketing your device as described in your premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus permits your device to proceed to market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html

{3}------------------------------------------------

If you have any questions regarding the content of this letter, please contact Paul Hardy at (240) 276-3666.

Sincerely yours,

Dovê thi nhung

for Nancy C. Brogdon Director, Division of Reproductive, Abdominal and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure(s)

{4}------------------------------------------------

### Special 510(k) Premarket Notification GE LOGIQ-i/e & Vivid-e Compact Ultrasound September 28, 2007

### Diagnostic Ultrasound Indications for Use Form

# GE Compact Ultrasound System

LOGIQ-i, LOGIQ-e, Vivid-e

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

|                                                    | Mode of Operation |   |               |               |                  |                    |                  |                   |                     |                |       |
|----------------------------------------------------|-------------------|---|---------------|---------------|------------------|--------------------|------------------|-------------------|---------------------|----------------|-------|
| Clinical Application<br>Anatomy/Region of Interest | B                 | M | PW<br>Doppler | CW<br>Doppler | Color<br>Doppler | Color M<br>Doppler | Power<br>Doppler | Combined<br>Modes | Harmonic<br>Imaging | Coded<br>Pulse | Other |
| Ophthalmic                                         |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Fetal / Obstetrics                                 | P                 | P | P             | P             | P                | P                  | P                | P                 | P                   | P              |       |
| Abdominal[1]                                       | P                 | P | P             | P             | P                | P                  | P                | P                 | P                   | P              |       |
| Pediatric                                          | P                 | P | P             | P             | P                | P                  | P                | P                 | P                   | P              |       |
| Small Organ[2]                                     | P                 | P | P             | P             | P                | P                  | P                | P                 | P                   | P              |       |
| Neonatal Cephalic                                  | P                 | P | P             | P             | P                | P                  | P                | P                 | P                   | P              |       |
| Adult Cephalic                                     | P                 | P | P             | P             | P                | P                  | P                | P                 | P                   | P              |       |
| Cardiac[3]                                         | P                 | P | P             | P             | P                | P                  | P                | P                 | P                   | P              |       |
| Peripheral Vascular                                | P                 | P | P             | E             | P                | P                  | P                | P                 | P                   | P              |       |
| Musculo-skeletal Conventional                      | P                 | P | P             |               | P                |                    | P                | P                 | P                   | P              |       |
| Musculo-skeletal Superficial                       |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Other[4]                                           | P                 | P | P             | P             | P                | P                  | P                | P                 | P                   | P              |       |
| Exam Type, Means of Access                         |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Transesophageal                                    |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Transrectal                                        | P                 | P | P             |               | P                |                    | P                | P                 | P                   |                |       |
| Transvaginal                                       | P                 | P | P             |               | P                |                    | P                | P                 | P                   |                |       |
| Transuretheral                                     |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Intraoperative                                     | P                 | P | P             |               | P                |                    | P                | P                 | P                   | E              |       |
| Intraoperative Neurological                        |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Intravascular                                      |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Laparoscopic                                       |                   |   |               |               |                  |                    |                  |                   |                     |                |       |

N = new indication; P = previously cleared by FDA; E = added under Appendix E

Notes: [1] Abdominal includes renal, GYN/Pelvic

[2] Small organ includes breast, testes, thyroid.

[3] Cardiac is Adult and Pediatric.

[4] Other use includes Urology/Prostate

[*] Combined modes are B/M, B/PWD, B/Color/PWD, B/Power/PWD.

] Coded Pulse is for digitally encoded harmonics and B-flow.

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Aran M. Whay
(Division Sign-Off)

Division of Reproductive, Abdominal and Radiological Devices 510(k) Number

{5}------------------------------------------------

### Special 510(k) Premarket Notification GE LOGIQ-ile & Vivid-e Compact Ultrasound September 28, 2007

### Diagnostic Ultrasound Indications for Use Form

# GE Compact Ultrasound with 4C-RS Transducer

### LOGIQ-i, LOGIQ-e, Vivid-e

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

|                                                    | Mode of Operation |   |               |               |                  |                    |                  |                   |                     |                 |       |
|----------------------------------------------------|-------------------|---|---------------|---------------|------------------|--------------------|------------------|-------------------|---------------------|-----------------|-------|
| Clinical Application<br>Anatomy/Region of Interest | B                 | M | PW<br>Doppler | CW<br>Doppler | Color<br>Doppler | Color M<br>Doppler | Power<br>Doppler | Combined<br>Modes | Harmonic<br>Imaging | Coded<br>Pulse* | Other |
| Ophthalmic                                         |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Fetal / Obstetrics                                 | P                 | P | P             |               | P                |                    | P                | P                 | P                   | P               |       |
| Abdominal[1]                                       | P                 | P | P             |               | P                |                    | P                | P                 | P                   | P               |       |
| Pediatric                                          | P                 | P | P             |               | P                |                    | P                | P                 | P                   | P               |       |
| Small Organ (specify)                              |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Neonatal Cephalic                                  |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Adult Cephalic                                     |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Cardiac[3]                                         |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Peripheral Vascular                                |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Musculo-skeletal Conventional                      |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Musculo-skeletal Superficial                       |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Other[4]                                           | P                 | P | P             |               | P                |                    | P                | P                 | P                   | P               |       |
| Exam Type, Means of Access                         |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Transesophageal                                    |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Transrectal                                        |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Transvaginal                                       |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Transuretheral                                     |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Intraoperative (specify)                           |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Intraoperative Neurological                        |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Intravascular                                      |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Laparoscopic                                       |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |

N = new indication; P = previously cleared by FDA; E = added under Appendix E

Notes: [1] Abdominal includes GYN;

[3] Cardiac is Adult and Pediatric.

[4] Other use includes Urology;

[*] Combined modes are B/M, B/PWD, B/Color/PWD, B/Power/PWD.

[*] Coded Pulse is for digitally encoded harmonics and B-flow.

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

loure M. Whan

(Division Sign-Off) Division of Reproductive, Abdominal and Radiological Devices 510(k) Number

Prescription User (Per 21 CFR 801.109)

{6}------------------------------------------------

# GE Compact Ultrasound with 8C-RS Transducer

### LOGIQ-i, LOGIQ-e, Vivid-e

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

| Clinical Application<br>Anatomy/Region of Interest | B | M | PW<br>Doppler | CW<br>Doppler | Color<br>Doppler | Color M<br>Doppler | Power<br>Doppler | Combined<br>Modes | Harmonic<br>Imaging | Coded<br>Pulse | Other |
|----------------------------------------------------|---|---|---------------|---------------|------------------|--------------------|------------------|-------------------|---------------------|----------------|-------|
| Ophthalmic                                         |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Fetal / Obstetrics                                 |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Abdominal[1]                                       | P | P | P             |               | P                |                    | P                | P                 | P                   |                |       |
| Pediatric                                          | P | P | P             |               | P                |                    | P                | P                 | P                   |                |       |
| Small Organ (specify)                              | P | P | P             |               | P                |                    | P                | P                 | P                   |                |       |
| Neonatal Cephalic                                  | P | P | P             |               | P                |                    | P                | P                 | P                   |                |       |
| Adult Cephalic                                     |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Cardiac[3]                                         | P | P | P             |               | P                |                    | P                | P                 | P                   |                |       |
| Peripheral Vascular                                | P | P | P             |               | P                |                    | P                | P                 | P                   |                |       |
| Musculo-skeletal Conventional                      | P | P | P             |               | P                |                    | P                | P                 | P                   |                |       |
| Musculo-skeletal Superficial                       |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Other[4]                                           |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Exam Type, Means of Access                         |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Transesophageal                                    |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Transrectal                                        |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Transvaginal                                       |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Transuretheral                                     |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Intraoperative (specify)                           |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Intraoperative Neurological                        |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Intravascular                                      |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Laparoscopic                                       |   |   |               |               |                  |                    |                  |                   |                     |                |       |

N = new indication; P = previously cleared by FDA; E = added under Appendix E

Notes: [1] Abdominal includes GYN/Pelvic, Renal and Aorta-iliac artery;

[3] Cardiac is Adult and Pediatric.

[*] Combined modes are B/M, B/PWD, B/Color/PWD, B/Power/PWD.

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Lozue M. Whay

(DIAKS oductive, Abdominal a Division of Radiological Devices 510(k) Number

Prescription User (Per 21 CFR 801.109)

{7}------------------------------------------------

# GE Compact Ultrasound with E8C-RS Transducer

### LOGIQ-i, LOGIQ-e, Vivid-e

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

|                                                     | Mode of Operation |   |            |            |               |                 |               |                |                  |             |
|-----------------------------------------------------|-------------------|---|------------|------------|---------------|-----------------|---------------|----------------|------------------|-------------|
| Clinical Application<br>Anatomy/ Region of Interest | B                 | M | PW Doppler | CW Doppler | Color Doppler | Color M Doppler | Power Doppler | Combined Modes | Harmonic Imaging | Coded Pulse |
| Ophthalmic                                          |                   |   |            |            |               |                 |               |                |                  |             |
| Fetal / Obstetrics                                  | P                 | P | P          |            | P             |                 | P             | P              | N                |             |
| Abdominal [1]                                       | P                 | P | P          |            | P             |                 | P             | P              | N                |             |
| Pediatric                                           |                   |   |            |            |               |                 |               |                |                  |             |
| Small Organ (specify)                               |                   |   |            |            |               |                 |               |                |                  |             |
| Neonatal Cephalic                                   |                   |   |            |            |               |                 |               |                |                  |             |
| Adult Cephalic                                      |                   |   |            |            |               |                 |               |                |                  |             |
| Cardiac                                             |                   |   |            |            |               |                 |               |                |                  |             |
| Peripheral Vascular                                 |                   |   |            |            |               |                 |               |                |                  |             |
| Musculo-skeletal Conventional                       |                   |   |            |            |               |                 |               |                |                  |             |
| Musculo-skeletal Superficial                        |                   |   |            |            |               |                 |               |                |                  |             |
| Other [4]                                           | P                 | P | P          |            | P             |                 | P             | P              | N                |             |
| Exam Type, Means of Access                          |                   |   |            |            |               |                 |               |                |                  |             |
| Transesophageal                                     |                   |   |            |            |               |                 |               |                |                  |             |
| Transrectal                                         | P                 | P | P          |            | P             |                 | P             | P              | N                |             |
| Transvaginal                                        | P                 | P | P          |            | P             |                 | P             | P              | N                |             |
| Transuretheral                                      |                   |   |            |            |               |                 |               |                |                  |             |
| Intraoperative (specify)                            |                   |   |            |            |               |                 |               |                |                  |             |
| Intraoperative Neurological                         |                   |   |            |            |               |                 |               |                |                  |             |
| Intravascular                                       |                   |   |            |            |               |                 |               |                |                  |             |
| Laparoscopic                                        |                   |   |            |            |               |                 |               |                |                  |             |

N = new indication; P = previously cleared by FDA; E = added under Appendix E

Notes: [1] Abdominal includes GYN/Pelvic;

[4] Other use includes Urology/Prostate;

[*] Combined modes are B/M, B/PWD, B/Color/PWD, B/Power/PWD.

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE)

Prescription User (Per 21 CFR 801.109)

Loyu Th-Whag

Division of Reproductive, Abdominal Radiological Devices 510(k) Number

{8}------------------------------------------------

## GE Compact Ultrasound with 8L-RS Transducer

### LOGIQ-i, LOGIQ-e, Vivid-e

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

|                                                    | Mode of Operation |   |               |               |                  |                    |                  |                   |                     |                 |       |
|----------------------------------------------------|-------------------|---|---------------|---------------|------------------|--------------------|------------------|-------------------|---------------------|-----------------|-------|
| Clinical Application<br>Anatomy/Region of Interest | B                 | M | PW<br>Doppler | CW<br>Doppler | Color<br>Doppler | Color M<br>Doppler | Power<br>Doppler | Combined<br>Modes | Harmonic<br>Imaging | Coded<br>Pulse* | Other |
| Ophthalmic                                         |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Fetal / Obstetrics                                 |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Abdominal[1]                                       | P                 | P | P             |               | P                |                    | P                | P                 | P                   | P               |       |
| Pediatric                                          | P                 | P | P             |               | P                |                    | P                | P                 | P                   | P               |       |
| Small Organ (specify)[2]                           | P                 | P | P             |               | P                |                    | P                | P                 | P                   | P               |       |
| Neonatal Cephalic                                  |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Adult Cephalic                                     |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Cardiac[3]                                         | P                 | P | P             |               | P                |                    | P                | P                 | P                   |                 |       |
| Peripheral Vascular                                | P                 | P | P             |               | P                |                    | P                | P                 | P                   | P               |       |
| Musculo-skeletal Conventional                      | P                 | P | P             |               | P                |                    | P                | P                 | P                   |                 |       |
| Musculo-skeletal Superficial                       |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Other [4]                                          |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Exam Type, Means of Access                         |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Transesophageal                                    |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Transrectal                                        |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Transvaginal                                       |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Transuretheral                                     |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Intraoperative (specify)[5]                        | P                 | P | P             |               | P                |                    | P                | P                 | P                   |                 |       |
| Intraoperative Neurological                        |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Intravascular                                      |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |
| Laparoscopic                                       |                   |   |               |               |                  |                    |                  |                   |                     |                 |       |

N = new indication; P = previously cleared by FDA; E = added under Appendix E

Notes: [1] Abdominal includes GYN/Pelvic.

[3] Cardiac is Adult and Pediatric.

[5] Intraoperative includes abdominal, thoracic (cardiac), and vascular (PV).

[*] Combined modes are B/M, B/PWD, B/CWD, B/Color/PWD, B/Amplitude/PWD,

[*] Coded Pulse is for digitally encoded harmonics and B-flow.

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE)

Loyu Tn Whang

sion Sign-Off) Division of Reproductive, Abdominal and Radiological Devices 510(k) Number

{9}------------------------------------------------

# GE Compact Ultrasound with 9L-RS Transducer

LOGIQ-i, LOGIQ-e, Vivid-e

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

| Clinical Application<br>Anatomy/Region of Interest | Mode of Operation |   |            |            |               |                 |               |                |                  |             |       |
|----------------------------------------------------|-------------------|---|------------|------------|---------------|-----------------|---------------|----------------|------------------|-------------|-------|
|                                                    | B                 | M | PW Doppler | CW Doppler | Color Doppler | Color M Doppler | Power Doppler | Combined Modes | Harmonic Imaging | Coded Pulse | Other |
| Ophthalmic                                         |                   |   |            |            |               |                 |               |                |                  |             |       |
| Fetal / Obstetrics                                 |                   |   |            |            |               |                 |               |                |                  |             |       |
| Abdominal[1]                                       | E                 | E | E          |            | E             |                 | E             | E              | E                | E           |       |
| Pediatric                                          | E                 | E | E          |            | E             |                 | E             | E              | E                | E           |       |
| Small Organ (specify)[2]                           | E                 | E | E          |            | E             |                 | E             | E              | E                | E           |       |
| Neonatal Cephalic                                  |                   |   |            |            |               |                 |               |                |                  |             |       |
| Adult Cephalic                                     |                   |   |            |            |               |                 |               |                |                  |             |       |
| Cardiac[3]                                         |                   |   |            |            |               |                 |               |                |                  |             |       |
| Peripheral Vascular                                | E                 | E | E          |            | E             |                 | E             | E              | E                | E           |       |
| Musculo-skeletal Conventional                      | E                 | E | E          |            | E             |                 | E             | E              | E                | E           |       |
| Musculo-skeletal Superficial                       |                   |   |            |            |               |                 |               |                |                  |             |       |
| Other[4]                                           |                   |   |            |            |               |                 |               |                |                  |             |       |
| Exam Type, Means of Access                         |                   |   |            |            |               |                 |               |                |                  |             |       |
| Transesophageal                                    |                   |   |            |            |               |                 |               |                |                  |             |       |
| Transrectal                                        |                   |   |            |            |               |                 |               |                |                  |             |       |
| Transvaginal                                       |                   |   |            |            |               |                 |               |                |                  |             |       |
| Transuretheral                                     |                   |   |            |            |               |                 |               |                |                  |             |       |
| Intraoperative (specify)[5]                        | E                 | E | E          |            | E             |                 | E             | E              | E                | E           |       |
| Intraoperative Neurological                        |                   |   |            |            |               |                 |               |                |                  |             |       |
| Intravascular                                      |                   |   |            |            |               |                 |               |                |                  |             |       |
| Laparoscopic                                       |                   |   |            |            |               |                 |               |                |                  |             |       |

N = new indication; P = previously cleared by FDA; E = added under Appendix E

Notes: [1] Abdominal includes GYN/Pelvic,

[3] Cardiac is Adult and Pediatric.

[5] Intraoperative includes abdominal, thoracic (cardiac), and vascular (PV).

[*] Combined modes are B/M, B/PWD, B/CWD, B/Color/PWD, B/Amplitude/PWD,

[*] Coded Pulse is for digitally encoded harmonics and B-flow.

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE)

loyne M Whay

Division of Reproductive. Abd Radiological Devices 510(k) Number

{10}------------------------------------------------

# GE Compact Ultrasound with 12L-RS Transducer

### LOGIQ-i, LOGIQ-e, Vivid-e

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

|                                                    | Mode of Operation |   |               |               |                  |                    |                  |                   |                     |                 |
|----------------------------------------------------|-------------------|---|---------------|---------------|------------------|--------------------|------------------|-------------------|---------------------|-----------------|
| Clinical Application<br>Anatomy/Region of Interest | B                 | M | PW<br>Doppler | CW<br>Doppler | Color<br>Doppler | Color M<br>Doppler | Power<br>Doppler | Combined<br>Modes | Harmonic<br>Imaging | Coded<br>Pulse* |
| Ophthalmic                                         |                   |   |               |               |                  |                    |                  |                   |                     |                 |
| Fetal / Obstetrics                                 |                   |   |               |               |                  |                    |                  |                   |                     |                 |
| Abdominal                                          |                   |   |               |               |                  |                    |                  |                   |                     |                 |
| Pediatric                                          | P                 | P | P             |               | P                |                    | P                | P                 | P                   | P               |
| Small Organ[2]                                     | P                 | P | P             |               | P                |                    | P                | P                 | P                   | P               |
| Neonatal Cephalic                                  |                   |   |               |               |                  |                    |                  |                   |                     |                 |
| Adult Cephalic                                     |                   |   |               |               |                  |                    |                  |                   |                     |                 |
| Cardiac                                            |                   |   |               |               |                  |                    |                  |                   |                     |                 |
| Peripheral Vascular                                | P                 | P | P             |               | P                |                    | P                | P                 | P                   | P               |
| Musculo-skeletal Conventional                      | P                 | P | P             |               | P                |                    | P                | P                 | P                   | P               |
| Musculo-skeletal Superficial                       |                   |   |               |               |                  |                    |                  |                   |                     |                 |
| Other (specify)                                    |                   |   |               |               |                  |                    |                  |                   |                     |                 |
| Exam Type, Means of Access                         |                   |   |               |               |                  |                    |                  |                   |                     |                 |
| Transesophageal                                    |                   |   |               |               |                  |                    |                  |                   |                     |                 |
| Transrectal                                        |                   |   |               |               |                  |                    |                  |                   |                     |                 |
| Transvaginal                                       |                   |   |               |               |                  |                    |                  |                   |                     |                 |
| Transuretheral                                     |                   |   |               |               |                  |                    |                  |                   |                     |                 |
| Intraoperative [5] (specify)                       |                   |   |               |               |                  |                    |                  |                   |                     |                 |
| Intraoperative Neurological                        |                   |   |               |               |                  |                    |                  |                   |                     |                 |
| Intravascular                                      |                   |   |               |               |                  |                    |                  |                   |                     |                 |
| Laparoscopic                                       |                   |   |               |               |                  |                    |                  |                   |                     |                 |

N = new indication; P = previously cleared by FDA; E = added under Appendix E

Notes: [2] Small organ includes breast, testes, thyroid.

[*] Combined modes are B/M, B/PWD, B/Color/PWD, B/Power/PWD,

[*] Coded Pulse is for digitally encoded harmonics and B-flow.

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE)

Lorry M. Whig

(Divisio ductive. Abdom Division of Re Radiological Devices 510(k) Number

{11}------------------------------------------------

## GE Compact Ultrasound with i12L-RS Transducer

### LOGIQ-i, LOGIQ-e, Vivid-e

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

| Clinical Application<br>Anatomy/Region of Interest | Mode of Operation |   |               |               |                  |                    |                  |                   |                     |                |       |
|----------------------------------------------------|-------------------|---|---------------|---------------|------------------|--------------------|------------------|-------------------|---------------------|----------------|-------|
|                                                    | B                 | M | PW<br>Doppler | CW<br>Doppler | Color<br>Doppler | Color M<br>Doppler | Power<br>Doppler | Combined<br>Modes | Harmonic<br>Imaging | Coded<br>Pulse | Other |
| Ophthalmic                                         |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Fetal / Obstetrics                                 |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Abdominal[1]                                       | P                 | P | P             |               | P                |                    | P                | P                 | P                   | P              |       |
| Pediatric                                          | P                 | P | P             |               | P                |                    | P                | P                 | P                   | P              |       |
| Small Organ (specify)[2]                           | P                 | P | P             |               | P                |                    | P                | P                 | P                   | P              |       |
| Neonatal Cephalic                                  |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Adult Cephalic                                     |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Cardiac[3]                                         | P                 | P | P             |               | P                |                    | P                | P                 | P                   |                |       |
| Peripheral Vascular                                | P                 | P | P             |               | P                |                    | P                | P                 | P                   | P              |       |
| Musculo-skeletal Conventional                      | P                 | P | P             |               | P                |                    | P                | P                 | P                   |                |       |
| Musculo-skeletal Superficial                       |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Other[4]                                           |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Exam Type, Means of Access                         |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Transesophageal                                    |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Transrectal                                        |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Transvaginal                                       |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Transuretheral                                     |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Intraoperative (specify)[5]                        | P                 | P | P             |               | P                |                    | P                | P                 | P                   |                |       |
| Intraoperative Neurological                        |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Intravascular                                      |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Laparoscopic                                       |                   |   |               |               |                  |                    |                  |                   |                     |                |       |

N = new indication; P = previously cleared by FDA; E = added under Appendix E

Notes: [1] Abdominal includes GYN.

[2] Small organ includes breast, testes, thyroid.

[3] Cardiac is Adult and Pediatric.

[5] Intraoperative includes abdominal, thoracic (cardiac), and vascular (PV).

[*] Combined modes are B/M, B/PWD, B/CWD, B/Color/PWD, B/Amplitude/PWD.

["] Coded Pulse is for digitally encoded harmonics and B-flow.

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Aryu M. Why

Radiolog 510(k) Numbe

{12}------------------------------------------------

# GE Compact Ultrasound with i/t739-RS Transducers

### LOGIQ-i, LOGIQ-e, Vivid-e

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

| Clinical Application<br>Anatomy/Region of Interest | B | M | PW<br>Doppler | CW<br>Doppler | Color<br>Doppler | Color M<br>Doppler | Power<br>Doppler | Combined<br>Modes | Harmonic<br>Imaging | Coded<br>Pulse | Other |
|----------------------------------------------------|---|---|---------------|---------------|------------------|--------------------|------------------|-------------------|---------------------|----------------|-------|
| Ophthalmic                                         |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Fetal / Obstetrics                                 |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Abdominal[1]                                       | P | P | P             |               | P                |                    | P                | P                 | P                   |                |       |
| Pediatric                                          | P | P | P             |               | P                |                    | P                | P                 | P                   |                |       |
| Small Organ (specify)[2]                           | P | P | P             |               | P                |                    | P                | P                 | P                   |                |       |
| Neonatal Cephalic                                  |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Adult Cephalic                                     |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Cardiac[3]                                         | P | P | P             |               | P                |                    | P                | P                 | P                   |                |       |
| Peripheral Vascular                                | P | P | P             |               | P                |                    | P                | P                 | P                   |                |       |
| Musculo-skeletal Conventional                      |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Musculo-skeletal Superficial                       |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Other[4]                                           |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Exam Type, Means of Access                         |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Transesophageal                                    |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Transrectal                                        |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Transvaginal                                       |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Transuretheral                                     |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Intraoperative (specify)[5]                        | P | P | P             |               | P                |                    | P                | P                 | P                   |                |       |
| Intraoperative Neurological                        |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Intravascular                                      |   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Laparoscopic                                       |   |   |               |               |                  |                    |                  |                   |                     |                |       |

N = new indication; P = previously cleared by FDA; E = added under Appendix E

Notes: [3] Cardiac is Adult and Pediatric via intraoperative.

[5] Intraoperative includes abdominal, thoracic (cardiac), and vascular (PV).

[*] Combined modes are B/M, B/PWD, B/CWD, B/Color/PWD, B/Amplitude/PWD.

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE)

lory m Wh

Prescription User (Per 21 CFRivision of Reproductive, Abd Radiolog 510(k) Nun

{13}------------------------------------------------

# GE Compact Ultrasound with 3S-RS Transducer

### LOGIQ-i, LOGIQ-e, Vivid-e

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

|                                                    | Mode of Operation |   |            |            |               |                 |               |                |                  |              |       |
|----------------------------------------------------|-------------------|---|------------|------------|---------------|-----------------|---------------|----------------|------------------|--------------|-------|
| Clinical Application<br>Anatomy/Region of Interest | B                 | M | PW Doppler | CW Doppler | Color Doppler | Color M Doppler | Power Doppler | Combined Modes | Harmonic Imaging | Coded Pulse* | Other |
| Ophthalmic                                         |                   |   |            |            |               |                 |               |                |                  |              |       |
| Fetal / Obstetrics                                 | P                 | P | P          | P          | P             | P               | P             | P              | P                | P            |       |
| Abdominal[1]                                       | P                 | P | P          | P          | P             | P               | P             | P              | P                | P            |       |
| Pediatric                                          | P                 | P | P          | P          | P             | P               | P             | P              | P                | P            |       |
| Small Organ (specify)                              |                   |   |            |            |               |                 |               |                |                  |              |       |
| Neonatal Cephalic                                  |                   |   |            |            |               |                 |               |                |                  |              |       |
| Adult Cephalic                                     | P                 | P | P          | P          | P             | P               | P             | P              | P                | P            |       |
| Cardiac[3]                                         | P                 | P | P          | P          | P             | P               | P             | P              | P                | P            |       |
| Peripheral Vascular                                |                   |   |            |            |               |                 |               |                |                  |              |       |
| Musculo-skeletal Conventional                      |                   |   |            |            |               |                 |               |                |                  |              |       |
| Musculo-skeletal Superficial                       |                   |   |            |            |               |                 |               |                |                  |              |       |
| Other[4]                                           | P                 | P | P          | P          | P             | P               | P             | P              | P                | P            |       |
| Exam Type, Means of Access                         |                   |   |            |            |               |                 |               |                |                  |              |       |
| Transesophageal                                    |                   |   |            |            |               |                 |               |                |                  |              |       |
| Transrectal                                        |                   |   |            |            |               |                 |               |                |                  |              |       |
| Transvaginal                                       |                   |   |            |            |               |                 |               |                |                  |              |       |
| Transuretheral                                     |                   |   |            |            |               |                 |               |                |                  |              |       |
| Intraoperative (specify)                           |                   |   |            |            |               |                 |               |                |                  |              |       |
| Intraoperative Neurological                        |                   |   |            |            |               |                 |               |                |                  |              |       |
| Intravascular                                      |                   |   |            |            |               |                 |               |                |                  |              |       |
| Laparoscopic                                       |                   |   |            |            |               |                 |               |                |                  |              |       |

N = new indication; P = previously cleared by FDA; E = added under Appendix E

Notes: [1] Abdominal includes GYN/Pelvic, Renal and Aorta-iliac artery;

[3] Cardiac is Adult and Pediatric.

[*] Combined modes are B/M, B/PWD, B/Color/PWD, B/Power/PWD.

[1] Coded Pulse is for digitally encoded harmonics and B-flow.

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE)

Aorue M. Whay

(Divis Division of Reproductive. Abdominal Radiological Devices 510(k) Number

E-11

{14}------------------------------------------------

# GE Compact Ultrasound with 6S-RS Transducer

### LOGIQ-i, LOGIQ-e, Vivid-e

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

|                                                    | Mode of Operation |   |               |               |                  |                    |                  |                   |                     |                |       |
|----------------------------------------------------|-------------------|---|---------------|---------------|------------------|--------------------|------------------|-------------------|---------------------|----------------|-------|
| Clinical Application<br>Anatomy/Region of Interest | B                 | M | PW<br>Doppler | CW<br>Doppler | Color<br>Doppler | Color M<br>Doppler | Power<br>Doppler | Combined<br>Modes | Harmonic<br>Imaging | Coded<br>Pulse | Other |
| Ophthalmic                                         |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Fetal / Obstetrics                                 |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Abdominal[1]                                       | E                 | E | E             | E             | E                | E                  | E                | E                 | E                   | E              |       |
| Pediatric                                          | E                 | E | E             | E             | E                | E                  | E                | E                 | E                   | E              |       |
| Small Organ (specify)[2]                           |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Neonatal Cephalic                                  | E                 | E | E             | E             | E                | E                  | E                | E                 | E                   | E              |       |
| Adult Cephalic                                     | E                 | E | E             | E             | E                | E                  | E                | E                 | E                   | E              |       |
| Cardiac [3]                                        | E                 | E | E             | E             | E                | E                  | E                | E                 | E                   | E              |       |
| Peripheral Vascular                                |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Musculo-skeletal Conventional                      |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Musculo-skeletal Superficial                       |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Other [4]                                          | E                 | E | E             | E             | E                | E                  | E                | E                 | E                   | E              |       |
| Exam Type, Means of Access                         |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Transesophageal                                    |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Transrectal                                        |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Transvaginal                                       |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Transuretheral                                     |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Intraoperative (specify)[5]                        |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Intraoperative Neurological                        |                   |   |               |               |                  |                    |                  |                   |                     |                |       |
| Intravascular                                      |                   |   |               |               |                  |                    |                  |                   |                     |                |       |

N = new indication; P = previously cleared by FDA; E = added under Appendix E

Notes: [1] Abdominal includes GYN.

[3] Cardiac is Adult and Pediatric.

[4] Other use includes Urology.

[*] Combined modes are B/M, B/PWD, B/CWD, B/Color/PWD, B/Amplitude/PWD.

[*] Coded Pulse is for digitally encoded harmonics and B-flow.

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE)

Lonne In Whaz

Reproductive, Abdom Radiological Devices 510(k) Number

Prescription User (Per 21 CFR 801.109)

{15}------------------------------------------------

## GE Compact Ultrasound with P2D Transducer

LOGIQ-i, LOGIQ-e, Vivid-e

Intended Use: Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

|                                                    | Mode of Operation |   |            |            |               |                 |               |                |                  |             |       |
|----------------------------------------------------|-------------------|---|------------|------------|---------------|-----------------|---------------|----------------|------------------|-------------|-------|
| Clinical Application<br>Anatomy/Region of Interest | B                 | M | PW Doppler | CW Doppler | Color Doppler | Color M Doppler | Power Doppler | Combined Modes | Harmonic Imaging | Coded Pulse | Other |
| Ophthalmic                                         |                   |   |            |            |               |                 |               |                |                  |             |       |
| Fetal / Obstetrics                                 |                   |   |            |            |               |                 |               |                |                  |             |       |
| Abdominal[1]                                       |                   |   |            |            |               |                 |               |                |                  |             |       |
| Pediatric                                          |                   |   |            |            |               |                 |               |                |                  |             |       |
| Small Organ (specify)[2]                           |                   |   |            |            |               |                 |               |                |                  |             |       |
| Neonatal Cephalic                                  |…

---

**Source:** [https://fda.innolitics.com/submissions/RA/subpart-b%E2%80%94diagnostic-devices/IYO/K072797](https://fda.innolitics.com/submissions/RA/subpart-b%E2%80%94diagnostic-devices/IYO/K072797)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
