K965105 · U.S. Imaging Tables, Inc. · IXR · Jan 30, 1997 · Radiology
Device Facts
Record ID
K965105
Device Name
ELECTROPHYSIOLOGY TILT TABLE MODEL #9660
Applicant
U.S. Imaging Tables, Inc.
Product Code
IXR · Radiology
Decision Date
Jan 30, 1997
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 892.1980
Device Class
Class 2
Intended Use
This device, the Electrophysiology™ Tilt Table (Model 9660) and the Deluxe™ Arm Stretcher, Model 9660 are designed for clinical applications such as: to position patients for a diagnostic procedure employing some imaging technique or to position a patient for various treatments in clinics or hospitals. This device is used by a physician or a health care professional; this device is not operated by a patient.
Device Story
Electrophysiology™ Tilt Table (Model 9660) and Deluxe™ Arm Stretcher (Model 9660) provide mechanical support and adjustment to position patients for diagnostic imaging or clinical treatments. Operated by physicians or healthcare professionals in hospitals/clinics. Device facilitates patient access for imaging systems via adjustable arrangements. Design utilizes conventional materials and construction methods similar to existing imaging tables. Benefits include stable patient positioning to support diagnostic and therapeutic procedures.
Clinical Evidence
Bench testing only; no clinical data provided.
Technological Characteristics
Mobile fluoroscopic tilting table. Mechanical support and adjustment system. Conventional materials and construction consistent with industry standards for imaging tables. Class II device (21 CFR 892.11980).
Indications for Use
Indicated for patients requiring positioning for diagnostic imaging procedures or clinical treatments in hospital or clinic settings. Not for patient self-use.
Regulatory Classification
Identification
A radiologic table is a device intended for medical purposes to support a patient during radiologic procedures. The table may be fixed or tilting and may be electrically powered.
Special Controls
*Classification.* Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 892.9.
Predicate Devices
Deluxe “C” Arm Stretcher, Model 056-004 (Biodex Medical Systems, Inc.)
Related Devices
K965096 — FLUOROVIEW SERIES FLUOROSCOPIC TABLES · U.S. Imaging Tables, Inc. · Jan 27, 1997
K973039 — LEGACY/LEGACY-D TABLE · GE Medical Systems · Oct 16, 1997
Submission Summary (Full Text)
{0}
JAN 30 1997
19965105/A1
DUPLICATE
# EXHIBIT 15
## Summary of Safety & Effectiveness
This device, the *Electrophysiology™ Tilt Table* (Model 9660) and the *Deluxe™ Arm Stretcher*, Model 9660 are designed for clinical applications such as: to position patients for a diagnostic procedure employing some imaging technique or to position a patient for various treatments in clinics or hospitals. This device is used by a physician or a health care professional; this device is not operated by a patient. This is a Class II device. As such this device has a Classification name as: Mobile Fluoroscopic Tilting Table, as described in 21 CFR Part 892.11980. *U.S. Imaging Tables, Incorporated* has determined this device is substantially equivalent to a predicate medical device which is currently in commerce and is identified as: Deluxe “C” Arm Stretcher, Model 056-004, and is manufactured by Biodex Medical Systems, Inc. of Shirley New York.
A determination of substantial equivalence is based upon the following:
1. This device offers mechanical support and adjustment to suspend and position a patient into various arrangements where various parts of the patient would be accessible to an imaging system.
2. This device uses conventional design, construction and those materials commonly found in most similar Tables. This device uses conventional design, construction and those materials similar to the predicate, substantially equivalent device {except where this device is suited to a more general purpose design}.
3. This device has benefited from design, development, testing and production procedures that conform to Good Manufacturing Procedures.
4. This device has performance characteristics substantially equivalent to its predicate device {which includes differences to facilitate the various clinical applications for which it is intended}.
5. This device is safe and effective for the application for which it is intended and has been tested to confirm its safety and effectiveness.
U.S. Imaging Tables, Incorporated continues to search all appropriate sources for information relating to safety and effectiveness and maintains an in-house reporting system to identify adverse safety and effectiveness information and as such, applicable data is recorded for this device.
## CERTIFICATION:
I hereby certify that this Summary of Safety and Effectiveness applies for the above indicated device.
November 19, 1996
Date

Signed by
Mr. Ronald Denezzo
Acting Operations Manager
U.S. Imaging Tables, Incorporated
28 Central Avenue
Happauge, NY 11788
V-516 231 7300
F-516 231 7542
24\DLVR\24111A.DOC
Sheet 1 of 1
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.