BTL-785MJ

K243290 · BTL Industries, Inc. · NUW · May 9, 2025 · Physical Medicine

Device Facts

Record IDK243290
Device NameBTL-785MJ
ApplicantBTL Industries, Inc.
Product CodeNUW · Physical Medicine
Decision DateMay 9, 2025
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 890.5850
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The BTL-785MJ device with the controller and single-use applicators has the following indications for use: 1. To relieve symptoms associated with muscle spasm, to treat temporomandibular joint (TMJ) dysfunction and associated pain 2. Muscle re-education 3. Increasing blood flow 4. Maintain or increase mandibular range of motion

Device Story

BTL-785MJ is an electrostimulation platform for dental applications. System comprises main unit, handpiece, holding arm, connection cables, single-use applicators, and therapy discomfort button. User operates via large color touch screen; on-screen interface provides step-by-step guidance for therapy procedures and parameter setting. Device delivers electromagnetic field to human tissues to induce muscle stimulation. Used in clinical settings by healthcare professionals. Output includes therapy type, remaining time, and parameters. Clinical benefit includes symptom relief for muscle spasm and TMJ dysfunction, muscle re-education, improved blood flow, and enhanced mandibular range of motion.

Clinical Evidence

No clinical data. Bench testing only, including electrical safety (IEC 60601-1, IEC 60601-2-10), EMC (IEC 60601-1-2), usability (IEC 60601-1-6), software life cycle (IEC 62304), risk management (ISO 14971), and biocompatibility (ISO 10993-1, -5, -10).

Technological Characteristics

Electrostimulation platform; Class II, BF electrical safety. Output: rectangular pulse shape, 2 channels, max 80 mA current. Electrodes: silver conductive ink with hydrogel, 10-5000 Ohm impedance. Dimensions: 53.94" x 26.38" x 26.38". Connectivity: touch screen interface. Standards: IEC 60601-1, IEC 60601-1-2, IEC 60601-2-10, IEC 62304, ISO 14971, ISO 10993.

Indications for Use

Indicated for patients requiring relief of muscle spasm symptoms, treatment of TMJ dysfunction and associated pain, muscle re-education, increased blood flow, and maintenance or increase of mandibular range of motion.

Regulatory Classification

Identification

A powered muscle stimulator is an electrically powered device intended for medical purposes that repeatedly contracts muscles by passing electrical currents through electrodes contacting the affected body area.

Predicate Devices

Reference Devices

Submission Summary (Full Text)

{0} FDA U.S. FOOD & DRUG ADMINISTRATION May 9, 2025 BTL Industries, Inc. David Chmel CEO North America 362 Elm Street Marlborough, Massachusetts 01752 Re: K243290 Trade/Device Name: BTL-785MJ Regulation Number: 21 CFR 890.5850 Regulation Name: Powered Muscle Stimulator Regulatory Class: Class II Product Code: NUW, NFO Dated: October 18, 2024 Received: April 10, 2025 Dear David Chmel: We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. U.S. Food & Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 www.fda.gov {1} K243290 - David Chmel Page 2 Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download). Your device is also subject to, among other requirements, the Quality System (QS) regulation (21 CFR Part 820), which includes, but is not limited to, 21 CFR 820.30, Design controls; 21 CFR 820.90, Nonconforming product; and 21 CFR 820.100, Corrective and preventive action. Please note that regardless of whether a change requires premarket review, the QS regulation requires device manufacturers to review and approve changes to device design and production (21 CFR 820.30 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181). Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050. All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems. For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory- {2} K243290 - David Chmel Page 3 assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely, MICHAEL E. ADJODHA -S Michael E. Adjodha, MChE, RAC, CQIA Assistant Director DHT1B: Division of Dental and ENT Devices OHT1: Office of Ophthalmic, Anesthesia, Respiratory, ENT, and Dental Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health Enclosure {3} DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration Indications for Use Form Approved: OMB No. 0910-0120 Expiration Date: 07/31/2026 See PRA Statement below. Submission Number (if known) K243290 Device Name BTL-785MJ Indications for Use (Describe) The BTL-785MJ device with the controller and single-use applicators has the following indications for use: 1. To relieve symptoms associated with muscle spasm, to treat temporomandibular joint (TMJ) dysfunction and associated pain 2. Muscle re-education 3. Increasing blood flow 4. Maintain or increase mandibular range of motion Type of Use (Select one or both, as applicable) ☑ Prescription Use (Part 21 CFR 801 Subpart D) ☐ Over-The-Counter Use (21 CFR 801 Subpart C) # CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {4} BTL Industries # 510(k) Summary – K243290 ## General Information Sponsor: BTL Industries, Inc. 362 Elm Street Marlborough, MA 01752 Tel: +1-866-285-1656 Fax: +1-888-499-2502 Applicant: BTL Industries, Inc. 362 Elm Street Marlborough, MA 01752 Tel: +1-866-285-1656 Fax: +1-888-499-2502 Contact Person: David Chmel BTL Industries, Inc. chmel@btlnet.com Summary Preparation Date: May 08, 2025 ## Device Trade/Proprietary Name: BTL-785MJ Common Name: Stimulator, muscle, powered, dental Primary Classification Name: Powered muscle stimulator Classification Regulation: 21 CFR 890.5850, Class II Primary Product Code: NUW Secondary Product Code: NFO 510(k) Summary Page 1 of 6 {5} BTL Industries # Legally Marketed Predicate Device The BTL-785MJ is substantially equivalent to the following product(s) that are already cleared for distribution in the USA under the following 510(k) Premarket Notification numbers: ## Primary predicate: Device name: D function Original 510(k) Sponsor: ITO CO., LTD. 510(k) Number: K203525 ## Reference device: Device name: BTL-785BNF-E Original 510(k) Sponsor: BTL Industries, Inc. 510(k) Number: K242532 # Product Description The BTL-785MJ is a state-of-the-art electrostimulation and radiofrequency platform with accessories that enables the application of therapy by electrical stimulation. The control unit of the system is equipped with a large color touch screen that facilitates the use of the device. The on-screen information guides the user step-by-step through the entire therapy procedure. The therapeutic parameters are set using the touch screen of the device. During the therapy the device displays information about the applied therapy type, remaining therapy time and main therapy parameters on the screen. The generated electromagnetic field is intended to interact with the tissues of the human body in order to relieve symptoms associated with muscle spasm, to treat temporomandibular joint (TMJ) dysfunction and associated pain, muscle re-education, increase blood flow and maintain or increase mandibular range of motion. The BTL-785MJ device consists of the following main components: - Main unit - Handpiece - Holding arm - Connection cables - Single-use applicators - Therapy discomfort button 510(k) Summary {6} BTL Industries # Indications for Use The BTL-785MJ device with the controller and single-use applicators has the following indications for use: 1. To relieve symptoms associated with muscle spasm, to treat temporomandibular joint (TMJ) dysfunction and associated pain 2. Muscle re-education 3. Increasing blood flow 4. Maintain or increase mandibular range of motion # Non-clinical Testing (Performance Data) The BTL-785MJ device has been thoroughly evaluated for electrical safety. The device has been found to comply with applicable medical device safety standards: IEC 60601-1 Medical electrical equipment – Part 1: General requirements for basic safety and essential performance IEC 60601-1-2 Medical electrical equipment – Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic disturbances – Requirements and tests IEC 60601-2-10 Medical electrical equipment – Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators IEC 60601-1-6 Medical electrical equipment – Part 1-6: General requirements for basic safety and essential performance – Collateral standard: Usability IEC 62304 Medical device software – Software life cycle processes ISO 14971 Medical devices – Application of risk management to medical devices ISO 10993-1 Biological evaluation of medical devices – Part 1: Evaluation and testing within a risk management process ISO 10993-5 Biological evaluation of medical devices – Part 5: Tests for in vitro cytotoxicity ISO 10993-10 Biological evaluation of medical devices – Part 10: Tests for irritation and skin sensitization # Clinical performance data A clinical study was not conducted. 510(k) Summary {7} BTL Industries Comparison with the Predicate Device | 510(k) number Device name Company name: | K243290 BTL-785MJ BTL Industries, Inc. | K203525 D function ITO CO., LTD. | K242532 BTL-785BNF-E BTL Industries, Inc. | | --- | --- | --- | --- | | Type | Subject device | Predicate device | Reference device | | Product Code and Regulation | Physical medicine Dental 21 CFR 890.5850 NUW – Stimulator, Muscle, Powered, Dental | Physical medicine Dental 21 CFR 890.5850 NUW – Stimulator, Muscle, Powered, Dental | Neurology Neurology 21 CFR 882.5890 NFO – Stimulator, Transcutaneous Electrical, Aesthetic Purposes | | Indications for Use | The BTL-785MJ device with the controller and single-use applicators has the following indications for use: 1. To relieve symptoms associated with muscle spasm, to treat temporomandibular joint (TMJ) dysfunction and associated pain 2. Muscle re-education 3. Increasing blood flow 4. Maintain or increase mandibular range of motion | 1) To relieve symptoms associated with muscle spasm, to treat temporomandibular joint (TMJ) dysfunction and associated pain 2) Muscle re-education 3) Increasing blood flow 4) Maintain or increase mandibular range of motion | The BTL-785BNF-E device has the following indications for use: The device is indicated for aesthetic use including facial and neck or body skin stimulation. | | Principle of Action | Electrostimulation | Electrostimulation | Electrostimulation | | Clinical Use | Prescription use | Prescription use | Prescription use | 510(k) Summary {8} BTL Industries | Energy Source | 100 – 120 V AC, 50/60 Hz 200 – 240 V AC, 50/60 Hz | AC 100-240V, 50/60Hz DC 12 V (AC adaptor) DC 7.4 (Lithium ion battery) | 100 – 120 V AC, 50/60 Hz 200 – 240 V AC, 50/60 Hz | | --- | --- | --- | --- | | Electrical Safety & EMC Testing | IEC 60601-1 IEC 60601-1-2 IEC 60601-2-10 | ANSI AAMI 60601-1 IEC 60601-1-2 IEC 60601-2-10 | IEC 60601-1 IEC 60601-1-2 IEC 60601-2-10 | | Energy Type | Electric stimulation | Electric stimulation | Electric stimulation | | Accessory Attachment Method | Pad – single-use applicator | Pad – single-use applicator | Pad – single-use applicator | | Therapy time | 20-60 minutes | 60 minutes (Up to 480 min) | 20 minutes | | Pulse Width | Preset 1: Up to 150 μs Preset 2: 488 μs | PAIN: Up to 150μs CARE: 488 μs MCR: 150ms | 160 μs | | Output Frequency (Hz) | Preset 1: Up to 200 Preset 2: 0.67 | PAIN: Up to 200 CARE: 0.67 MCR: 400 | 250 | | Output Current | Preset 1: Up to 80 mA Preset 2: Up to 80 mA | PAIN: Up to 80 mA CARE: 24 mA MCR: 750 μA | Up to 130 mA | | Max. Output Voltage [V] | BTL-785-7-2, -8 48,5V @ 500 Ω 48,5V @ 2000 Ω 0 @ 10 000 Ω | Not publicly available | BTL-785-7-2, -8 48,5V @ 500 Ω 48,5V @ 2000 Ω 0 @ 10 000 Ω | | Max. Current density at 500 Ω [μA/mm²] | BTL-785-7-2 – 200 μA/mm² BTL-785-7-8 -276 μA/mm² | Not publicly available | BTL-785-7-2 – 243 μA/mm² BTL-785-7-8 - 335 μA/mm² | | Max average power density at 500 Ω [W/cm²] | BTL-785-7-2 – 0,058 W/cm² BTL-785-7-8 -0.082 W/cm² | Not publicly available | BTL-785-7-2 – 0,047 W/cm² BTL-785-7-8 - 0,065 W/cm² | | Pulse Shape | Rectangular | Rectangular | Rectangular | | Channel Numbers | 2 | 2 | Up to 3 | 510(k) Summary Page 5 of 6 {9} BTL Industries | Electrical Safety Class | Class II, BF | Class II, BF | Class II, BF | | --- | --- | --- | --- | | Timer | Yes | Yes | Yes | | Buzzer | Yes | Yes | Yes | | Display | Yes | Yes | Yes | | (a) Electrodes materials (b) Electroconductive media (c) electrode-to-skin impedance range (d) conductive surface area | a) Conductive ink (Silver) | a) Not publicly available | a) Conductive ink (Silver) | | | b) Conductive hydrogel | b) Not publicly available | b) Conductive hydrogel | | | c) 10-5000 Ohm | c) Not publicly available | c) 10-5000 Ohm | | | d) BTL-785-7-2 - 4 cm² BTL-785-7-8 - 2.9 cm² | d) Not publicly available | d) BTL-785-7-2 - 4 cm² BTL-785-7-8 - 2.9 cm² | | System Weight | 65 kg (143 lb) | 230 g (0.5 lb) | 65 kg (143 lb) | | System Dimensions (W×H×D) | 53.94" × 26.38" × 26.38" | 3.3" × 0.93" × 5.9" | 53.94" × 26.38" × 26.38" | ## Substantial Equivalence The BTL-785MJ device has similar technological characteristics and the same intended use compared to the primary predicate device and comparable mode of action and intended use compared to reference device. Any differences between the predicate device and BTL-785MJ device have no significant influence on safety or effectiveness of the BTL-785MJ device. Therefore, the BTL-785MJ device is substantially equivalent to the predicate device. ## Conclusion Based upon the intended use, comparison of technical characteristics and performance testing provided in this premarket notification, the BTL-785MJ device has been shown to be substantially equivalent to the currently cleared predicate device for requested intended use. 510(k) Summary
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...