AB BELT PRO

K020429 · The Dezac Group · NGX · Sep 13, 2002 · Physical Medicine

Device Facts

Record IDK020429
Device NameAB BELT PRO
ApplicantThe Dezac Group
Product CodeNGX · Physical Medicine
Decision DateSep 13, 2002
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 890.5850
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The Ab Belt Pro device is indicated for use for the improvement of abdominal muscle tone, for strengthening of the abdominal muscles and for developing a firmer abdomen.

Device Story

Ab Belt Pro is a single-channel, battery-operated powered muscle stimulator; designed for abdominal muscle exercise. System comprises an electronic stimulation controller and a wearable fabric belt with three integrated electrodes. User wraps belt around abdomen; central electrode positioned over umbilicus; outer electrodes positioned toward mid-axillary line. Device generates pulsed electrical stimulation signals; current passes between outer and center electrodes only. Powered by three 1.5V AAA batteries. Intended for consumer use to improve muscle tone and strength. Provides non-invasive muscle stimulation; helps users achieve firmer abdominal appearance.

Clinical Evidence

No clinical data provided; substantial equivalence based on technological characteristics and performance standards.

Technological Characteristics

Powered muscle stimulator (21 CFR 890.5850). Single-channel electronic stimulation controller. Three electrodes connected via press-studs to a fabric belt. Conductive gel used for skin interface. Battery-powered (3x 1.5V AAA). Complies with 21 CFR 898 performance standards.

Indications for Use

Indicated for improvement of abdominal muscle tone, strengthening of abdominal muscles, and development of a firmer abdomen in users.

Regulatory Classification

Identification

A powered muscle stimulator is an electrically powered device intended for medical purposes that repeatedly contracts muscles by passing electrical currents through electrodes contacting the affected body area.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ ## SEP 1 3 2002 #### 2.0 510(K) SUMMARY #### 2.1 Sponsor Information | Sponsor | The Dezac Group | |--------------|------------------------| | | 54-56 Bath Road | | | Cheltenham, Glos. | | | GL53 7HG | | | United Kingdom | | Registration | in England No. 2186341 | Mr. Kevin Herbert, Project Engineer Contact Person Phone +44 1242 702300 Fax +44 1242 702301 E-mail kherbert@dezac.co.uk #### 2.2 Device Name | Trade Name of Device | Ab Belt Pro | |----------------------|---------------------------| | Common Name | Muscle Stimulator | | Classification name | Powered Muscle Stimulator | | Product Code | NGX | | Regulation Class | II | | Regulation Number | 890.5850 | #### 2.3 Indications for Use The Ab Belt Pro device is indicated for use for the improvement of abdominal muscle tone, for strengthening of the abdominal muscles and for developing a firmer abdomen. #### Device Description 2.4 The Ab Belt Pro is a single channel battery operated muscle stimulation system specifically designed to exercise the abdominal muscles for the purposes of improving abdominal muscle tone, strengthening the abdominal muscles and developing a firmer abdomen. 10F 3 {1}------------------------------------------------ 20F=3/KOLOSI It comprises an electronic stimulation controller module which generates the required electrical stimulation signals and an abdominally worn electrode belt which connects the signals from the stimulator to the skin electrodes located on the inner surface of the belt. The device is supplied with a set of three identical electrodes, a tube of conductive gel, an instruction manual, a set of batteries and a fabric belt extension for fuller figures. Power is derived from three (3) 1.5V AAA batteries located in a compartment protected by a removal battery cover at the rear (belt side) of the device. The central umbilical electrode is common to each of the left and right stimulation circuits. The electrodes connect mechanically to 'press-studs' mounted on the inner face of the abdominal belt. The studs are presented in such a way that each of the outer electrodes may be rotated about a single common stud to accommodate both inner and outer muscle groups. Only these single common studs of the outer electrodes and the central umbilical electrically connected to the stimulator unit. This prevents stimulation to the user through a stud, which is not covered by an electrode pad. The user extends the belt and puts it in a wrapping motion from front to back, closing it at the back using Velcro patches. When the belt is in place the central electrode locates over the umbilicus and the two outer electrodes locate on either side of the body towards the mid axillary line, between the pelvis and the rib cage. It is well known in the art that this electrode positioning is particularly useful for stimulating the abdominal muscles. The pulsed stimulation current passes between the outer and center electrodes only. There is no current passed from outer electrode to outer electrode. The user has no access to the wiring or connectors as they are stored internally within the belt structure. As a result he or she cannot alter the current path and so the possibilities for misuse are greatly reduced. #### 2.5 Basis for Substantial Equivalence ## Predicate Device Slendertone™ Flex: K010335 (Class II) Bio-Medical Research Ltd c/o Mr. Robert Dormer {2}------------------------------------------------ # KO20439 3013 Hyman, Phelps & McNamara, P.C. 700 13th Street NW, Suite 1200 Washington, D.C. 20005 - The Ab Belt Pro device has the same indications for use as the predicate device. . - The Ab Belt Pro device has equivalent technological characteristics and instructions for use, . as compared to the predicate device. - . The device meets the mandatory performance standard identified in 21 CFR 898. - The biocompatibility of the electrodes has been established. . - The conductive gel is a legally-marketed gel cleared through 510(k) number K983964. . {3}------------------------------------------------ Image /page/3/Picture/1 description: The image shows the seal of the U.S. Department of Health & Human Services. The seal is circular and contains the words "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" around the perimeter. Inside the circle is a stylized image of three human profiles facing to the right, with the profiles overlapping each other. The profiles are black and the background is white. SFP 1 3 2002 Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 Mr. Kevin Herbert The Dezac Group 54-56 Bath Road Cheltenham, Glos. GL53 7HG United Kingdom Re: K020429 Trade/Device Name: Ab Belt Pro Regulation Number: 21 CFR 890.5850 Regulation Name: Powered Muscle Stimulator Regulatory Class: Class II Product Code: NGX Dated: September 9, 2002 Received: September 10, 2002 Dear Mr. Herbert: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice {4}------------------------------------------------ Page 2 -- Mr. Kevin Herbert requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.qov/cdrh/dsma/dsmamain.html Sincerely vours. Sincerely yours, Mark N Milburn Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative, and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ ### Indications for use statement 510(k) number (if known): K020429 . Device Name: AbBelt Pro Sponsor Name: The Dezac Group Indications for use: The AbBelt Pro is indicated for use for improvement of abdominal muscle tone, for strengthening of the abdominal muscles, and for the development of a firmer abdomen. Mark N. Milliman (Division Sign-Off) (Division Sigil-On), Restorative Divis on on on of cess 510(k) Number --
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...