RECOVER INFANT HEEL WARMER (5100)

K964523 · Florida Medical Industries, Inc. · MPO · Feb 10, 1997 · Physical Medicine

Device Facts

Record IDK964523
Device NameRECOVER INFANT HEEL WARMER (5100)
ApplicantFlorida Medical Industries, Inc.
Product CodeMPO · Physical Medicine
Decision DateFeb 10, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 890.5710
Device ClassClass 1
AttributesTherapeutic, Pediatric

Indications for Use

The Recover® Infant Heel Warmer is intended to be used for warming the heel site of an infant prior to a heel stick procedure. The warmth enhances vasodilation and increases blood flow in an infant’s heel to ensure adequate blood for sampling.

Device Story

Disposable hot pack; used to warm infant heel prior to blood sampling. Contents: food-grade sodium acetate, water, stainless steel catalytic disc; sealed in nylon/polyethylene laminate bag. Activation via disc manipulation; provides heat to 105°F. Used in clinical settings by healthcare providers to facilitate blood collection; improves sampling success by increasing local blood flow.

Clinical Evidence

Bench testing only; no clinical data provided.

Technological Characteristics

Disposable hot pack; materials: food-grade sodium acetate, water, stainless steel catalytic disc, nylon/polyethylene laminate bag. Thermal energy source: exothermic crystallization triggered by catalytic disc. Form factor: flexible pouch.

Indications for Use

Indicated for infants requiring heel stick blood sampling to enhance vasodilation and blood flow at the heel site.

Regulatory Classification

Identification

A hot or cold disposable pack is a device intended for medical purposes that consists of a sealed plastic bag incorporating chemicals that, upon activation, provides hot or cold therapy for body surfaces.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} K964523 FEB 10 1997 # 510(K) SUMMARY (as required by 807.92(c)) ## Submitter of 510(k): Regulatory & Marketing Services, Inc. (RMS) 40178 U.S. 19 North Tarpon Springs, FL 34689 Phone: 813-942-3908 Fax: 813-942-3828 ## Contact Person: Patrick J. Lamb or Edward H. Ransom ## Date of Summary: October 18, 1996 ## Trade Name: Recover® Infant Heel Warmer ## Classification Name: Pack, Hot, Disposable ## Predicate Device: Florida Medical Industries, Recover® Infant Heel Warmer Pre 1976 Device ## Device Description/ Comparison: Non Toxic, Food Grade Sodium Acetate and water with a stainless steel catalytic disc sealed in a nylon /polyethylene laminate bag. Provides heat to 105°F. | | Proposed Device | Marketed Device | | --- | --- | --- | | | Florida Medical Industries | Florida Medical Industries | | Contents | Food-grade sodium acetate and water. Disc: Stainless Steel Catalytic disc. | Magnesium Sulphate (Kieserite); Colloidal Clay; water. | | Temp. | 105° | 105° | ## Intended Use: The Recover® Infant Heel Warmer is intended to be used for warming the heel site of an infant prior to a heel stick procedure. The warmth enhances vasodilation and increases blood flow in an infant’s heel to ensure adequate blood for sampling.
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...