K991658 · Permobil AB · ITI · Oct 8, 1999 · Physical Medicine
Device Facts
Record ID
K991658
Device Name
PERMOBIL POWERED WHEELCHAIR 1280
Applicant
Permobil AB
Product Code
ITI · Physical Medicine
Decision Date
Oct 8, 1999
Decision
SESE
Submission Type
Abbreviated
Regulation
21 CFR 890.3860
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The intended use of Permobil powered wheelchair 1280 is to provide indoor and outdoor mobility to persons restricted to a sitting position.
Device Story
Front-wheel-driven, battery-powered wheelchair; provides indoor/outdoor mobility for users restricted to sitting position. Input: user manipulation of joystick integrated into Penny & Giles Pilot+ controller. Operation: two 12V 73Ah batteries power drive unit (motor/gear/brakes) mounted on welded steel base frame. Output: mechanical movement of wheelchair. Used in various environments; operated by patient. Healthcare provider uses device to restore mobility; output affects patient independence and quality of life.
Indicated for persons restricted to a sitting position requiring indoor and outdoor mobility.
Regulatory Classification
Identification
A powered wheelchair is a battery-operated device with wheels that is intended for medical purposes to provide mobility to persons restricted to a sitting position.
K982064 — ACTION STORM RANGER II, ACTION STORM POWER 9000 · Invacare Corp. · Oct 5, 1998
K250758 — Electric Wheelchair (F309) · Changshu Pingfang Wheelchair Co., Ltd. · May 9, 2025
K232783 — Power wheelchair (Model: JMPW-01W) · Jiangsu Jumao X-Care Medical Equipment Co., Ltd. · Jan 19, 2024
K031711 — TANGO, MODELS, BP1 · American Bantex Corp. · Dec 18, 2003
K231508 — Power Wheelchair, W5521 · Zhejiang Innuovo Rehabilitation Devices Co.,Ltd · Nov 9, 2023
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the word "permobil" in a bold, sans-serif font, with the "o" in "mobil" stylized as a circle. The word is enclosed in a thin, black oval. The text and oval are black against a white background.
- ブ
#### OCT 8 1999
1252
## 510(K) SUMMARY OF SAFETY AND EFFECTIVENESS
# K991658
## PERMOBIL POWERED WHEELCHAIR 1280
| Submitter | Permobil AB<br>Box 120<br>S-861 23 Timrå<br>Sweden |
|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Phone<br>Fax | +46 60 59 59 00<br>+46 60 57 52 50 |
| Contact person<br>E-mail address | Bengt Persson<br>bengt.persson@permobil.se |
| Date Prepared | May 10 1999 |
| Device name | Powered wheelchair 1280 |
| Classification name | Powered wheelchair |
| Identification of predicate devices | Permobil Chairman L/CS 8 (K960951)<br>G-424 power wheelchair (K983677) |
| Intended use | The intended use of Permobil powered wheelchair 1280 is to provide indoor and<br>outdoor mobility to persons restricted to a sitting position. |
| Description of the device | The Permobil powered wheelchair 1280 is front wheel driven, battery powered,<br>motor driven and is controlled by the Penny & Giles compact powered wheelchair<br>controller Pilot +. The joystick is integrated in the controller.<br>The wheelchair is powered by two 12V 73 Ah batteries.<br>Theoretical driving range on the fully charged batteries is 35 km.<br>The wheelchair consists of two basic sub-sections. These are the base with motor<br>controller and the body supporting system. In this submission, only the design<br>changes made to base is included. The base is of welded steel construction and<br>includes the base frame, front drive wheels with drive unit (motor/gear/brakes),<br>batteries and pivoting rear casters. The motor controller is mounted to the left or<br>right armrest, depending on user needs.<br>The motor controller, including the joystick, is housed in a pressure die cast<br>aluminum enclosure. |
| Substantial equivalence<br>The Permobil powered wheelchair 1280 is substantial equivalent with respect to,<br>intended use, energy source and materials, because those are identical to the<br>predicate device(s). | |
The key changes are frame suspension and use of the Pilot + controller from Penny & Giles instead of the PG8 controller from Penny & Giles.
{1}------------------------------------------------
Image /page/1/Picture/0 description: The image shows the word "permobil" in a bold, sans-serif font, enclosed in an oval shape. The word is written in lowercase letters, with the "o" slightly smaller and raised compared to the other letters. The oval shape is a simple black line that surrounds the word, providing a border for the logo.
## 510(K) SUMMARY OF SAFETY AND EFFECTIVENESS
## PERMOBIL POWERED WHEELCHAIR 1280
Jos
1699/1658
### Safety and effectiveness
The Permobil powered wheelchair 1280 has in substantials the same technological characteristics and the same safety and effectiveness as the predicate device(s) and the minor design changes declared in this submission do not raise new questions of safety and effectiveness.
{2}------------------------------------------------
Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized image of a bird-like figure, possibly representing an eagle or other national symbol. The bird is depicted with flowing lines, giving it a sense of movement and freedom.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
OCT 8 1999
Mr. Bengt Persson Quality Manager Permobil A.B. Engelbrekts Vag 101 S-191 62 Sollentuna, Sweden
Re: K991658
> Trade Name: Permobil Powered Wheelchair 1280 Regulatory Class: II Product Code: ITI Dated: July 7, 1999 Received: July 12, 1999
Dear Mr. Persson:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition. FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
{3}------------------------------------------------
#### Page 2 - Mr. Bengt Persson
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4595. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely vours.
Mark N Milhusan
Celia M. Witten, Ph.D., M.D. Director
Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
Image /page/4/Picture/0 description: The image shows the word "permobil" in a bold, sans-serif font, with the "o" in "mobil" being smaller and slightly raised. The word is enclosed in a black oval. The background is white, providing a clear contrast to the black text and oval.
## PERMOBIL POWERED WHEELCHAIR 1280
### Indication for Use
The intended use is to provide indoor and outdoor mobility to persons restricted to a sitting position.
#### 510(k) number
Not assigned at the writing of this submission
#### Device name
Not decided at writing of this submission Working name, also use in this submission, 1280
#### Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription use (per 21 CFR 801.109) □
or
Over the counter use of
Mark M. Mellikerson
---
(Division Sign Off)
(Division Sign-Off) Division of Ggeneral Restorative Devices
510(k) number
(k) number K99/65Y
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.