K991132 · Hoveround Corp. · INI · Oct 20, 1999 · Physical Medicine
Device Facts
Record ID
K991132
Device Name
ACTIVA
Applicant
Hoveround Corp.
Product Code
INI · Physical Medicine
Decision Date
Oct 20, 1999
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 890.3800
Device Class
Class 2
Indications for Use
TO PROVIDE FOR THE CONSUMING POBLIC, SELF-CONTAINED, COMPACT PERSONAL MOBILITY VEHICLE FOR PERSONS WHO ARE UNABLE TO AMBULATE EITHER BECAUSE OF MEDICAL NECESSITY OR THROUGH PERSONAL PERSONAL PREFERENCE VEHICLE IS OPERABLE BOTH INDOORS AND OU 198 THE FOR OUTDOOR USAGE. PRIMARILY INTENDED
Device Story
Motorized 3-wheeled scooter; battery-operated via two rechargeable lead-acid batteries. Features platform connecting three wheels (one front, two rear), adjustable tiller, and operator seat. Operator controls speed and steering via hand controls on tiller. Maximum weight capacity 300 lbs. Includes battery charger. Used by patients for personal mobility in indoor and outdoor environments.
Indicated for individuals unable to ambulate due to medical necessity or personal preference requiring a personal mobility vehicle for indoor and outdoor use.
Regulatory Classification
Identification
A motorized three-wheeled vehicle is a gasoline-fueled or battery-powered device intended for medical purposes that is used for outside transportation by disabled persons.
K971388 — FREERIDER, MODEL FR168-4 · Freerider USA, Inc. · Jul 23, 1997
K041187 — A&I SCOOTER, SC-301 · Well Success Biotech, Inc. · May 25, 2004
Submission Summary (Full Text)
{0}------------------------------------------------
OCT 20 1999
## 510K_Summary of Substantial Equivalence
K99//32
Submitted by
Mr. Thomas E. Kruse, President Hoveround Corporation, 2151 Whitfield Industrial Way, Sarasota, FL. 34243 (941) 739 - 6200 Tel. (941) 727 - 8686 Fax.
Contact person
Stan Cooper
March 29th 1999 Date of Submission
Name of the Device Activa 3 Wheeled Scooter.
Scooter, powered, three wheeled Usual Name
Vehicle, Motorized, 3 Wheeled, Class 11 Classification Name
Regulation number 890.3800
Committee Physical Medicine
INI
Product Code
Device Claimed to be "Legend" 3 wheeled scooter. Substantially Equivalent Pride Healthcare Manufacturer
510K Number K915659
Issue Date 01 - 21 - 92
{1}------------------------------------------------
# Summary Description of Device.
K991132
The Hoveround Activa is a motorized three wheeled scooter. It is battery operated from two rechargeable lead-acid batteries. It consists of a platform which connects the three wheels, ( one at the center front, one each on the rear left and right sides ), an adjustable tiller and a seat for the operator.
The device can carry a sole seated operator of maximum weight 300 LB and is driven by using hand controls located at the top of the tiller also acting to steer the vehicle.
A battery charger is provided with each model to replenish batteries.
{2}------------------------------------------------
### DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo features a stylized depiction of an eagle with three heads, representing the department's focus on individuals, families, and communities. The eagle is encircled by the words "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA". The logo is simple and monochromatic.
#### Public Health Service
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
OCT 20 1999
Mr. Stan Cooper Hoveround Corporation 2151 Whitfield Industrial Way Sarasota, Florida 34243
K991132 Re: Trade Name: Activa Regulatory Class: II Product Code: INI Dated: July 22, 1999 Received: July 23, 1999
Dear Mr. Cooper:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions The general controls provisions of the Act of the Act. include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. ਜੋ substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. T Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Féderal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
{3}------------------------------------------------
#### Page 2 - Mr. Stan Cooper
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling requlation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact Also, please note the Office of Compliance at (301) 594-4639. the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours,
Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
510(k) Number (if known): __ K991132 ·
Device Name: ACTIVA_
Indications For Use. To PROVIDE FOR THE CONSUMING POBLIC, SELF-CONTAINED, COMPACT PERSONAL MOBILITY VEHICLE FOR PERSONS WHO ARE UNABLE TO AMBULATE EITHER BECAUSE OF MEDICAL NECESSITY OR THROUGH PERSONAL PERSONAL PREFERENCE VEHICLE IS OPERABLE BOTH INDOORS AND OU લુકા 198 THE FOR OUTDOOR USAGE. PRIMARILY INTENDED ਉਹਪ
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
(Division Sigh-Off)
Division of General Restorative Devices K991132
510(k) Number***_***_
Prescription Use (Per 21 CFR 801.109) OR
(Optional Formal 1-2-96)
Over-The-Counter Use
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.