Browse hierarchy: [Physical Medicine (PM)](/submissions/PM) → [Subpart D — Physical Medicine Prosthetic Devices](/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices) → [21 CFR 890.3110](/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/890.3110) → INO — Chair, Positioning, Electric

# INO · Chair, Positioning, Electric

_Physical Medicine · 21 CFR 890.3110 · Class 2_

**Canonical URL:** https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO

## Overview

- **Product Code:** INO
- **Device Name:** Chair, Positioning, Electric
- **Regulation:** [21 CFR 890.3110](/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/890.3110)
- **Device Class:** 2
- **Review Panel:** [Physical Medicine](/submissions/PM)

## Identification

An electric positioning chair is a device with a motorized positioning control that is intended for medical purposes and that can be adjusted to various positions. The device is used to provide stability for patients with athetosis (involuntary spasms) and to alter postural positions.

## Classification Rationale

Class II. The electric positioning chair is exempt from premarket notification procedures in subpart E of part 807 of this chapter, subject to § 890.9 and the following conditions for exemption:

## Special Controls

(1) Appropriate analysis and non-clinical testing must demonstrate that the safety controls are adequate to ensure safe use of the device and prevent user falls from the device in the event of a device failure; 
(2) Appropriate analysis and non-clinical testing must demonstrate the ability of the device to withstand the rated user weight load with an appropriate factor of safety; 
(3) Appropriate analysis and non-clinical testing must demonstrate the longevity of the device to withstand external forces applied to the device and provide the user with an expected service life of the device; 
(4) Appropriate analysis and non-clinical testing must demonstrate proper environments of use and storage of the device to maximize the longevity of the device; 
(5) Appropriate analysis and non-clinical testing (such as that outlined in the currently FDA-recognized editions of ANSI/AAMI/ES60601-1, “Medical Electrical Equipment—Part 1: General Requirements for Basic Safety and Essential Performance,” and ANSI/AAMI/IEC 60601-1-2, “Medical Electrical Equipment—Part 1-2: General Requirements for Basic Safety and Essential Performance—Collateral Standard: Electromagnetic Disturbances—Requirements and Tests”) must validate electromagnetic compatibility and electrical safety; 
(6) Appropriate analysis and non-clinical testing (such as that outlined in the currently FDA-recognized editions of ANSI/AAMI/ISO 10993-1, “Biological Evaluation of Medical Devices—Part 1: Evaluation and Testing Within a Risk Management Process,” ANSI/AAMI/ISO 10993-5, “Biological Evaluation of Medical Devices—Part 5: Tests for In Vitro Cytotoxicity,” and ANSI/AAMI/ISO 10993-10, “Biological Evaluation of Medical Devices—Part 10: Tests for Irritation and Skin Sensitization”) must validate that the skin-contacting components of the device are biocompatible; 
(7) Appropriate analysis and non-clinical testing (such as that outlined in the currently FDA-recognized editions of IEC 62304, “Medical Device Software—Software Life Cycle Processes”) must validate the software life cycle and that all processes, activities, and tasks are implemented and documented; 
(8) Appropriate analysis and non-clinical testing must validate that the device components are found to be non-flammable; 
(9) Appropriate analysis and non-clinical testing must validate that the battery in the device (if applicable) performs as intended over the anticipated service life of the device; and 
(10) Adequate patient labeling is provided to the user to document proper use and maintenance of the device to ensure safe use of the device by the patient in the intended use environment.

## Recent Cleared Devices (20 of 53)

Showing 20 most recent of 53 cleared devices.

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K131909](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K131909.md) | DALTON LIFT CHAIR | Dalton Instrument Corp. | Feb 24, 2014 | SESE |
| [K123834](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K123834.md) | EASYSTAND BANTAM MEDIUM | Altimate Medical, Inc. | Aug 13, 2013 | SESE |
| [K112944](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K112944.md) | FRESENIUS MEDICAL TREATMENT CHAIR T688 SERIES | Fresenius Medical Care South Asia Pacific Pty , Ltd. | Dec 30, 2011 | SESE |
| [K101723](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K101723.md) | COMPACT WHEELCHAIR PLATFORM | Design Specific Fletcher | Dec 23, 2010 | SESE |
| [K091578](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K091578.md) | LIFT CHAIR, MODEL T3 | Pride Mobility Products Corp. | Dec 2, 2009 | SESE |
| [K091727](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K091727.md) | MEDICAL TREATMENT CHAIR,  T400, T500,T600 | Fresenius Medical Care South Asia Pacific Pty , Ltd. | Jul 6, 2009 | SESE |
| [K091242](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K091242.md) | BANTAM | Altimate Medical, Inc. | Jul 6, 2009 | SESE |
| [K073565](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K073565.md) | STANDARD WHEELCHAIR PLATFORM | Design Specific , Ltd. | Feb 6, 2009 | SESE |
| [K081053](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K081053.md) | PIVOT ASSIST | Pivot Assist, LLC | Oct 9, 2008 | SESE |
| [K080533](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K080533.md) | WINCO MODEL POWER SERIES LIFT CHAIR | Winco, Inc. | Aug 11, 2008 | SESE |
| [K071793](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K071793.md) | CONVERTIBLE I-SERIES POSITIONING AND TRANSFER CHAIR | Barton Medical Corp. | Aug 3, 2007 | SESE |
| [K070950](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K070950.md) | LIFT CHAIR, MODEL C5 | Pride Mobility Products Corp. | Apr 16, 2007 | SESE |
| [K062402](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K062402.md) | EASYSTAND EVOLV | Invacare Corp. | Sep 21, 2006 | SESE |
| [K060212](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K060212.md) | MERITS MODEL E SERIES LIFT CHAIRS | Merits Health Products Co., Ltd. | Mar 7, 2006 | SESE |
| [K031045](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K031045.md) | AEROLET TOILET LIFT, MODEL AER-01 | Economic Holland B.V. | Jul 10, 2003 | SESE |
| [K023521](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K023521.md) | EASY LIFE | Berkline Corp. | Nov 19, 2002 | SESE |
| [K022407](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K022407.md) | MULTI FUCTIONAL REHABILITATION CHAIR | Raye'S, Inc. | Aug 16, 2002 | SESE |
| [K002318](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K002318.md) | UNITED #1018-FREEDOM SERIES, UNITED #2018-COMFORT SERIES, UNITED #3018-ELEGANCE SERIES, UNITED #5018-MASTER SERIES | United Chair Mfg., LLC | Oct 11, 2000 | SESE |
| [K001937](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K001937.md) | MEDLINE ELECTRONIC POSITIONING CHAIR | Medline Industries, Inc. | Sep 22, 2000 | SESE |
| [K002171](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO/K002171.md) | INVACARE LIFT CHAIR | Invacare Corp. | Aug 10, 2000 | SESE |

## Top Applicants

- Invacare Corp. — 4 clearances
- Altimate Medical, Inc. — 2 clearances
- Craftmatic/Contour Organization, Inc. — 2 clearances
- Fresenius Medical Care South Asia Pacific Pty , Ltd. — 2 clearances
- Penox Technologies, Inc. — 2 clearances

---

**Source:** [https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO](https://fda.innolitics.com/submissions/PM/subpart-d%E2%80%94physical-medicine-prosthetic-devices/INO)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).