OEO · Automated Digital Image Manual Interpretation Microscope

Hematology · 21 CFR 864.1860 · Class 2

Overview

Product CodeOEO
Device NameAutomated Digital Image Manual Interpretation Microscope
Regulation21 CFR 864.1860
Device ClassClass 2
Review PanelHematology

Identification

Immunohistochemistry test systems (IHC's) are in vitro diagnostic devices consisting of polyclonal or monoclonal antibodies labeled with directions for use and performance claims, which may be packaged with ancillary reagents in kits. Their intended use is to identify, by immunological techniques, antigens in tissues or cytologic specimens. Similar devices intended for use with flow cytometry devices are not considered IHC's.

Classification Rationale

(1) Class I (general controls). Except as described in paragraphs (b)(2) and (b)(3) of this section, these devices are exempt from the premarket notification requirements in part 807, subpart E of this chapter. (2) Class II (special control, guidance document: “FDA Guidance for Submission of Immunohistochemistry Applications to the FDA,” Center for Devices and Radiologic Health, 1998). (3) Class III (premarket approval). IHC's intended for any use not described in paragraphs (b)(1) or (b)(2) of this section.

Special Controls

(2) Class II (special control, guidance document: “FDA Guidance for Submission of Immunohistochemistry Applications to the FDA,” Center for Devices and Radiologic Health, 1998). These IHC's are intended for the detection and/or measurement of certain target analytes in order to provide prognostic or predictive data that are not directly confirmed by routine histopathologic internal and external control specimens. These IHC's provide the pathologist with information that is ordinarily reported as independent diagnostic information to the ordering clinician, and the claims associated with these data are widely accepted and supported by valid scientific evidence. Examples of class II IHC's are those intended for semiquantitative measurement of an analyte, such as hormone receptors in breast cancer.

Recent Cleared Devices (6 of 6)

RecordDevice NameApplicantDecision DateDecision
K142965Virtuoso System for IHC PR (1E2) using iScan HTVentana Medical Systems, Inc.Jul 16, 2015SESE
K131140OMNYX IDP FOR HER2 MANUAL APPLICATIONOmnyx, LLCApr 1, 2014SESE
K130021PHILIPS HERCEPTEST DIGITAL SCOREPhilips Medical Systems Nederland B.V.Sep 19, 2013SESE
K111914VIRTUAL SLIDE SYSTEM, OLYMPUS VS800 SYSTEMOlympus America Inc. / Scientific Equipment GroupAug 21, 2012SESE
K080254SCANSCOPE XT SYSTEMAperio TechnologiesOct 31, 2008SESE
K071671SCANSCOPE XT SYSTEMAperio TechnologiesDec 28, 2007SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...