SYNTHES REAMER/IRRIGATOR/ASPIRATOR (RIA) SYSTEM

K993335 · Synthes (Usa) · HTO · Jun 12, 2000 · Orthopedic

Device Facts

Record IDK993335
Device NameSYNTHES REAMER/IRRIGATOR/ASPIRATOR (RIA) SYSTEM
ApplicantSynthes (Usa)
Product CodeHTO · Orthopedic
Decision DateJun 12, 2000
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.4540
Device ClassClass 1

Indications for Use

Synthes RIA System is intended to clear the medullary canal of bone marrow and debris and to effectively size the medullary canal for the acceptance of an intramedullary implant or prosthesis.

Device Story

RIA System comprises disposable reamer assemblies and reusable drive shafts; used for expedited medullary canal reaming prior to internal fixation. Device features free-rotating reamer head with manifold/tube assembly; enables simultaneous irrigation and aspiration during reaming. Irrigation delivered through reamer cannulation; aspiration drawn from rear of reamer flutes. Available in diameters 9-24 mm and lengths 200-550 mm. Operated by surgeons in clinical settings to prepare bone for implants; removes debris and marrow to facilitate prosthesis acceptance.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

System includes disposable reamer assemblies and reusable drive shafts. Features integrated irrigation and aspiration manifold. Reamer diameters: 9-24 mm; lengths: 200-550 mm. Mechanical device; no software or electronic components.

Indications for Use

Indicated for clearing medullary canal of bone marrow and debris and sizing canal for intramedullary implant or prosthesis placement.

Regulatory Classification

Identification

An orthopedic manual surgical instrument is a nonpowered hand-held device intended for medical purposes to manipulate tissue, or for use with other devices in orthopedic surgery. This generic type of device includes the cerclage applier, awl, bender, drill brace, broach, burr, corkscrew, countersink, pin crimper, wire cutter, prosthesis driver, extractor, file, fork, needle holder, impactor, bending or contouring instrument, compression instrument, passer, socket positioner, probe, femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image shows the word "SYNTHES" in bold, black letters. To the left of the word is a circular logo with a design inside. A small circled R symbol is located to the right of the word. JUN 1 2 2000 Image /page/0/Picture/2 description: The image shows a sequence of handwritten digits and a letter. The sequence starts with the letter 'K', followed by the digits '993335'. The digits are written in a simple, slightly irregular style. | Attachment VIII: | Summary of Safety and Effectiveness [510(k) Summary] | |------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | SUBMITTER | Synthes (USA) 1690 Russell Road Paoli, PA 19301 (610) 647-9700 | | | Contact: Sheri L. Musgnung | | DEVICE NAME: | Synthes Reamer/Irrigator/Aspirator (RIA) System | | COMMON OR USUAL NAME | Jet lavage; Vacuum-powered body fluid suction apparatus; Arthroscope | | DEVICE CLASSIFICATION: | Class II, 21 CFR 880.5475; 880.6740; and 888.1100 | | PREDICATE DEVICE: | Synthes Inramedullary Reamers Zimmer's Flexible Intramedullary Reamer Davol's Pneumatic Arthroscopy Pulsed Irrigator System | | DESCRIPTION: | The RIA System consists of two types of components; a series of disposable reamer assemblies and reusable drive shafts. The RIA is a device designed for expedited reaming of a medullary canal in preparation of internal fixation. The device includes a free rotating reamer head connected to the distal end of the manifold/tube assembly. The manifold allows both irrigation and aspiration during the reaming process. Irrigation is passed through the cannulation of the reamer and aspiration is drawn from the rear of the flutes in the reamer. The RIA coupled with the Drive Shaft serves as a flexible reaming device and is available in reaming diameters ranging from 9 mm to 24 mm and range in 200 mm to 550 mm in effective reaming lengths. | | INTENDED USE: | Synthes RIA System is intended to clear the medullary canal of bone marrow and debris and to effectively size the medullary canal for the acceptance of an intramedullary implant or prosthesis | CONFIDENTIAL prosthesis. {1}------------------------------------------------ ## DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is a stylized image of an eagle with three overlapping wings. ### Public Health Service Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 # JUN 1 2 2000 Ms. Sheri L. Musgnung Regulatory Affairs Specialist Synthes (USA) 1690 Russell Road P.O. Box 1766 Paoli. Pennsylvania 19301 K993335 Re: > Trade Name: Synthes Reamer/IrrigatorAspirator (RIA) System Regulatory Class: II Product Code: HTO, HRX Dated: May 1. 2000 Received: May 2, 2000 Dear Ms. Musgnung: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition. FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. {2}------------------------------------------------ ## Page 2 - Ms. Sheri L. Musgnung This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4595. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html". Sincerely yours, Dana R. Lochner - Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {3}------------------------------------------------ Image /page/3/Picture/0 description: The image shows the word "SYNTHES" in a bold, sans-serif font. To the left of the word is a circular logo with a stylized figure inside. A registered trademark symbol is located to the right of the word. #### Indications for Use Statement 2.0 | | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | |--|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| 510(k) Number (if known): Synthes Reamer/Irrigator/Aspirator (RIA) System Device Name: (99333) Indications For Use: Synthes RIA System is intended to clear the medullary canal of bone marrow and debris and to effectively size the medullary canal for the acceptance of an intramedullary implant or prosthesis. (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) S Prescription Use (Per 21 CFR 801.109) OR Over-The-Counter Use Danne R. Vachner. (Division Sign-Off) (Division Sign-On) Division of General Restorative Devices 943335 510(k) Number ڪلا Synthes (USA) Reamer/Irrigator/Aspirator (RIA) System CONFIDENTIAL 000004
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...