A clinical literature review and analysis of the PearlDiver reimbursement database were conducted to assess the safety and efficacy of using allograft in conjunction with the device in the lumbar spine to support an expanded indication.
Allograft; Claims database; Literature review; Safety and efficacy
Clinical Evidence
Study Design
Population
Comparator
Key Endpoints
Clinical literature review and PearlDiver reimbursement analysis; Retrospective literature review and claims database analysis
Patients undergoing lumbar spine fusion with allograft
Not applicable for this study
Safety and efficacy of allograft use
Indications for Use
The STALIF TT™, STALIF MIDLINE®, MIDLINE II™, and MIDLINE II-Ti™ is indicated for use with bone graft (autograft bone and/or allogenic bone graft composed of cancellous and/or corticocancellous bone graft) in patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1. These DDD patients may also have up to Grade I Spondylolisthesis or retrolisthesis at the involved levels. DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had six months of non-operative treatment. Patients with previous non-fusion spinal surgery at the treated level may be treated. These implants may be implanted via a laparoscopic or an open anterior approach. The STALIF TT™, STALIF MIDLINE II™, and MIDLINE II-Ti™ is a stand-alone system intended to be used with the bone screws provided and requires no additional supplementary fixation systems. The STALIF TT™, STALIF MIDLINE II™, and MIDLINE II-Ti™ system must be used with autograft and/or allogenic bone graft composed of cancellous and/or corticocancellous bone graft.
Device Story
Radiolucent intervertebral body fusion (IBF) cages; used for spinal fusion in lumbar region (L2-S1). Device features central cavity for bone graft packing; includes unicortical cancellous bone screws for stand-alone fixation. Implanted via laparoscopic or open anterior approach by surgeons. Provides structural support to vertebral endplates; promotes fusion using autograft or allogenic bone graft. Benefits patients by stabilizing spinal segments and alleviating discogenic pain. Subject device expands previous indications to include allogenic bone graft usage.
Clinical Evidence
No new clinical trials performed. Evidence based on comprehensive clinical literature review and PearlDiver reimbursement analysis to assess safety and efficacy of allograft use in the lumbar spine. Previous biomechanical studies support equivalence to interbody cages with supplemental fixation.
Indicated for skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1, including those with up to Grade I Spondylolisthesis or retrolisthesis. Patients must have discogenic back pain confirmed by history/radiography and have failed six months of non-operative treatment. Includes patients with previous non-fusion spinal surgery at the treated level.
Regulatory Classification
Identification
An intervertebral body fusion device is an implanted single or multiple component spinal device made from a variety of materials, including titanium and polymers. The device is inserted into the intervertebral body space of the cervical or lumbosacral spine, and is intended for intervertebral body fusion.
Special Controls
*Classification.* (1) Class II (special controls) for intervertebral body fusion devices that contain bone grafting material. The special control is the FDA guidance document entitled “Class II Special Controls Guidance Document: Intervertebral Body Fusion Device.” See § 888.1(e) for the availability of this guidance document.(2) Class III (premarket approval) for intervertebral body fusion devices that include any therapeutic biologic (e.g., bone morphogenic protein). Intervertebral body fusion devices that contain any therapeutic biologic require premarket approval.
(c)
*Date premarket approval application (PMA) or notice of product development protocol (PDP) is required.* Devices described in paragraph (b)(2) of this section shall have an approved PMA or a declared completed PDP in effect before being placed in commercial distribution.
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features the department's name in a circular arrangement around a symbol. The symbol depicts a stylized representation of three human profiles facing to the right, stacked on top of each other. The profiles are rendered in a dark color, contrasting with the white background.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
June 8, 2015
Centinel Spine, Incorporated % Mr. Justin Eggleton Director, Spine Regulatory Affairs Musculoskeletal Clinical Regulatory Advisors, LLC. 1331 H Street, Northwest 12th Floor Washington, District of Columbia 20005
Re: K150643
Trade/Device Name: Centinel Spine STALIF TT™, STALIF MIDLINE 9, MIDLINE II™ and MIDLINE II-TiTM Regulation Number: 21 CFR 888.3080 Regulation Name: Intervertebral body fusion device Regulatory Class: Class II Product Code: OVD Dated: March 11, 2015 Received: March 12, 2015
Dear Mr. Eggleton:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing
{1}------------------------------------------------
Page 2 – Mr. Justin Eggleton
(21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
# Mark N. Melkerson -S
Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
# Indications for Use
510(k) Number (if known) K150643
Device Name
Centinel Spine STALIF TT™, STALIF MIDLINE®, MIDLINE II™, and MIDLINE II-Ti™
Indications for Use (Describe)
The STALIF TT™, STALIF MIDLINE®, MIDLINE II™, and MIDLINE II-Ti™ is indicated for use with bone graft (autograft bone and/or allogenic bone graft composed of cancellous bone graft) in patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1. These DDD patients may also have up to Grade I Spondylolisthesis or retrolisthesis at the involved levels. DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had six months of non-operative treatment. Patients with previous non-fusion spinal surgery at the treated level may be treated. These implants may be implanted via a laparoscopic or an open anterior approach.
The STALIF TT™, STALIF MIDLINE II™, and MIDLINE II-Ti™ is a stand-alone system intended to be used with the bone screws provided and requires no additional supplementary fixation systems.
The STALIF TT™, STALIF MIDLINE II™, and MIDLINE II-Ti™ system must be used with autograft and/or allogenic bone graft composed of cancellous and/or corticocancellous bone graft.
Type of Use (Select one or both, as applicable)
2 Prescription Use (Part 21 CFR 801 Subpart D)
_ Over-The-Counter Use (21 CFR 801 Subpart C)
#### PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON A SEPARATE PAGE IF NEEDED.
#### FOR FDA USE ONLY
Concurrence of Center for Devices and Radiological Health (CDRH) (Signature)
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Druq Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
# 510(k) Summary
| Device Trade Name: | Centinel Spine STALIF TTTM, STALIF MIDLINE®, MIDLINE<br>IITM, and MIDLINE II-TiTM |
|----------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Manufacturer: | Centinel Spine, Inc.<br>900 Airport Road, Suite 3B<br>West Chester, PA 19380 |
| Contact: | Mr. John Parry<br>Group Manager, Lumbar Technologies<br>Phone: (484) 887.8813 |
| Prepared by: | Mr. Justin Eggleton<br>Musculoskeletal Clinical Regulatory Advisers, LLC<br>1331 H Street NW, 12th Floor<br>Washington, DC 20005<br>Phone: (202) 552-5800<br>jeggleton@mcra.com |
| Date Prepared: | June 4, 2015 |
| Classifications: | 21 CFR §888.3080, Intervertebral Body Fusion Device. |
| Class: | II |
| Product Codes: | OVD |
| Primary Predicate Device: | K141942, (Centinel Spine MIDLINE IITM, and MIDLINE II-TiTM) |
| Additional Predicate<br>Devices: | K101301, K073109 (Centinel Spine STALIF TTTM, STALIF<br>MIDLINE®) |
# Indications For Use:
The STALIF TT™, STALIF MIDLINE®, MIDLINE II™, and MIDLINE II-Ti™ is indicated for use with bone graft (autograft bone and/or allogenic bone graft composed of cancellous and/or corticocancellous bone graft) in patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1. These DDD patients may also have up to Grade I Spondylolisthesis or retrolisthesis at the involved levels. DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had six months of non-operative treatment. Patients with previous non-fusion spinal surgery at the treated level may be treated. These implants may be implanted via a laparoscopic or an open anterior approach.
{4}------------------------------------------------
The STALIF TT™, STALIF MIDLINE®, MIDLINE II™, and MIDLINE II-Ti™ is a standalone system intended to be used with the bone screws provided and requires no additional supplementary fixation systems.
The STALIF TT™. STALIF MIDLINE@. MIDLINE III™. and MIDLINE II-Ti™ system must be used with autograft and/or allogenic bone graft composed of cancellous and/or corticocancellous bone graft.
## Device Description:
STALIF TTTTT, MIDLINE™/ MIDLINE II-Ti™ are radiolucent intervertebral body fusion cages with unicortical cancellous bone screws. It is intended to be used as an IBF cage without supplementary fixation. The cross section profile of the STALIF devices are similar to that of the vertebral body endplate with central cavity that can be packed with autograft or allograft. The STALIF devices are manufactured from PEEK-OPTIMA® LT1 with titanium alloy screws and X-ray marker wires manufactured from unalloyed Tantalum (ASTM F-560). The MIDLINE II-Ti™ is identical to this design with a titanium plasma spray coating on the device endplates.
The purpose of the subject 510(k) was to expand the indications to include use with allograft (i.e., allogenic bone graft composed of cancellous and/or corticocancellous bone graft).
Predicate Device (Summary of Technological Characteristics):
The subject STALF TTT", STALIF MIDLINE®, MIDLINE III™ Interbody Fusion Device System is substantially equivalent to the predicate MIDLINE™MIDLINE II-Ti™ Interbody Fusion Device System (K141942), STALIF MIDLINE® (K101301) and STALIF TTM (K073109) with respect to indications, design, function, and materials.
### Substantial Equivalence:
The subject and predicate STALIF TT™, STALIF MIDLINE®, MIDLINE III™, and MIDLINE II-Ti™ Device Systems are similar in design, material, and indicated use. A comprehensive, clinical literature review and PearlDiver reimbursement were conducted to assess the safety and efficacy of allograft used in conjunction with this device in the lumbar spine. This review concluded that there were no additional risks due to the modified indications for this device. Biomechanical studies were performed to demonstrate equivalence to interbody cages with supplemental fixation. No new mechanical tests were performed since there were no design changes to the device.
### Conclusion:
The Centinel Spine STALIF TT™, STALIF MIDLINE®, MIDLINE III™, and MIDLINE II-Ti™ have been modified to expand the indications to permit use with allograft (i.e., allogenic bone graft composed of cancellous and/or corticocancellous bone graft). The 510(k) demonstrates substantial equivalence to predicate devices.