MOSS MIAMI SPINAL SYSTEM
Device Facts
| Record ID | K962628 |
|---|---|
| Device Name | MOSS MIAMI SPINAL SYSTEM |
| Applicant | Depuy, Inc. |
| Product Code | KWP · Orthopedic |
| Decision Date | Mar 18, 1997 |
| Decision | SN |
| Submission Type | Traditional |
| Regulation | 21 CFR 888.3050 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The MOSS Miami Spinal System is intended for non-cervical use in the spine. When used with anterior screw fixation or posterior hook, non-pedicle screw fixation the MOSS Miami Spinal System is intended to treat scoliosis, kyphosis and lordosis, fracture, loss of stability due to tumor, spinal stenosis, spondylolisthesis, a previously failed back surgery or degenerative disc disease (i.e. discogenic back pain with degeneration of the disc confirmed by history and radiographic studies). When used with pedicle screw fixation, the MOSS Miami Spinal System is intended for use in patients with severe spondylolisthesis (Grades 3 and 4) at the L5-S1 vertebral joint, having fusions with autogenous bone graft, with the device fixed or attached to the lumbar and sacral spine (levels of pedicle screw fixation are L3 and below), and for whom the device system is intended to be removed after the development of a solid fusion mass.
Device Story
Spinal fixation system consisting of longitudinal rods, monoaxial screws, polyaxial screws, hooks, transverse/axial connectors, and washers. Components fabricated from stainless steel or titanium. System provides mechanical stabilization of spinal segments to facilitate fusion. Used by orthopedic or neurosurgeons in surgical settings. Input: surgical site anatomy; Output: rigid construct providing structural support. Benefits: correction of spinal deformities, stabilization of fractures, and management of degenerative conditions. This submission adds 4mm diameter rods and 6mm monoaxial screws to existing system; screw head slots narrowed to fit 4mm rods.
Clinical Evidence
No clinical data provided; substantial equivalence based on design, material, and mechanical performance characteristics.
Technological Characteristics
Materials: Stainless steel or titanium. Components: Longitudinal rods, monoaxial/polyaxial screws, hooks, connectors, washers. Design: Mechanical spinal interlaminal fixation orthosis. Connectivity: None. Software: None.
Indications for Use
Indicated for non-cervical spinal stabilization in patients with scoliosis, kyphosis, lordosis, fracture, tumor-related instability, spinal stenosis, spondylolisthesis, failed back surgery, or degenerative disc disease. Pedicle screw fixation indicated specifically for severe spondylolisthesis (Grades 3-4) at L5-S1, requiring autogenous bone graft fusion, with fixation at L3 and below; device removal intended post-fusion.
Regulatory Classification
Identification
A spinal interlaminal fixation orthosis is a device intended to be implanted made of an alloy, such as stainless steel, that consists of various hooks and a posteriorly placed compression or distraction rod. The device is implanted, usually across three adjacent vertebrae, to straighten and immobilize the spine to allow bone grafts to unite and fuse the vertebrae together. The device is used primarily in the treatment of scoliosis (a lateral curvature of the spine), but it also may be used in the treatment of fracture or dislocation of the spine, grades 3 and 4 of spondylolisthesis (a dislocation of the spinal column), and lower back syndrome.
Predicate Devices
- DePuy Motech MOSS Spinal System
- DePuy Motech MOSS Miami Spinal System, Pedicle Fixation
- DePuy Motech MOSS Spinal System, Pedicle Fixation