TRUMATCH PERSONALIZED SOLUTIONS

K110397 · DePuy Orthopaedics, Inc. · JWH · Aug 16, 2011 · Orthopedic

Device Facts

Record IDK110397
Device NameTRUMATCH PERSONALIZED SOLUTIONS
ApplicantDePuy Orthopaedics, Inc.
Product CodeJWH · Orthopedic
Decision DateAug 16, 2011
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3560
Device ClassClass 2

Intended Use

The TruMatch™ Patient Specific Instruments are intended to be used as patient-specific surgical instrumentation to assist in the positioning of a joint replacement component intra-operatively and in guiding the marking of bone before cutting. The anatomical landmarks necessary for the creation of the TruMatch™ Patient Specific Instruments must be present and identifiable on CT. The TruMatch™ Patient Specific Instruments are intended for use with Sigma® Total Knee Implants and Attune™ Total Knee Implants and their cleared indications for use. The TruMatch™ Patient Specific Instruments are intended for single use only.

Device Story

TruMatch™ Patient Specific Instruments are custom-manufactured surgical guides created from patient CT imaging data. These instruments assist surgeons during total knee arthroplasty by guiding bone marking and positioning of Sigma® or Attune™ knee implants. The process involves converting patient CT data into patient-specific physical guides used intra-operatively to improve surgical accuracy. The device is intended for single use. Surgeons use these guides to align implants according to the pre-operative plan derived from the patient's anatomy. The system aims to enhance the precision of bone cuts and component placement, potentially improving surgical outcomes for patients undergoing knee replacement.

Clinical Evidence

No clinical data. Substantial equivalence supported by bench testing, including dimensional stability tests, cadaver accuracy studies, and design/software repeatability and validation studies.

Technological Characteristics

Patient-specific surgical instruments manufactured from patient CT data. Designed for single-use. Technical validation includes dimensional stability, design process repeatability, and software verification. Compatible with Sigma and Attune knee implant systems.

Indications for Use

Indicated for patients undergoing total knee arthroplasty requiring joint replacement components; used to assist in intra-operative positioning and bone marking. Requires identifiable anatomical landmarks on CT scans. Contraindicated if landmarks are not present on CT.

Regulatory Classification

Identification

A knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a knee joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and a tibial component or components and a retropatellar resurfacing component made of ultra-high molecular weight polyethylene. This generic type of device is limited to those prostheses intended for use with bone cement (§ 888.3027).

Predicate Devices

Reference Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ #### 510(k) Summary AUG 16 2011 | Applicant / Sponsor: | DePuy Orthopaedics Inc.<br>700 Orthopaedic Drive<br>Warsaw, Indiana 46581-0988<br>Establishment Registration No.: 1818910 | |--------------------------|----------------------------------------------------------------------------------------------------------------------------| | Contact Person: | Nancy S. Friddle<br>Project Manager, Regulatory Affairs<br>Tel: (574) 371-4923<br>Fax: (574) 371-4987 | | Proprietary Name: | TruMatch™ Personalized Solutions | | Common Name: | Total Knee Prosthesis | | Classification Name: | 21 CFR 888.3560: Knee joint patellofemorotibial<br>polymer/metal/polymer semi-constrained cemented prosthesis.<br>Class II | | Product Code: | JWH | | Subsequent Product Code: | OOG | #### Device Description: Subject of this premarket notification are TruMatch™ Patient Specific Instruments which are designed and manufactured from patient imaging data and used with other DePuy Orthopaedics implants. #### Indications and Intended Use: The TruMatch™ Patient Specific Instruments are intended to be used as patient-specific surgical instrumentation to assist in the positioning of a joint replacement component intra-operatively and in guiding the marking of bone before cutting. The anatomical landmarks necessary for the creation of the TruMatch™ Patient Specific Instruments must be present and identifiable on CT. The TruMatch™ Patient Specific Instruments are intended for use with Sigma® Total Knee Implants and Attune™ Total Knee Implants and their cleared indications for use. The TruMatch™ Patient Specific Instruments are intended for single use only. : . {1}------------------------------------------------ ## Summary of Technologies/Substantial Equivalence: The TruMatch™ Patient Specific Instruments have the same indications, intended use, similar design and are substantially equivalent to the Smith & Nephew's Patient Matched Cutting Blocks and also to the traditional instruments that are associated with the Sigma® and Attune™ cleared knee implant systems. The TruMatch™ Patient Specific Instruments are used in conjunction with the DePuy Orthopaedics, Inc Sigma and Attune implant systems identified in the table below. | System | 510k | Clearance Date | |--------------------------|---------|----------------| | Sigma Total Knee System | K882234 | 10/20/1988 | | Sigma Total Knee System | K884796 | 3/29/1989 | | Sigma Total Knee System | K943462 | 12/21/1994 | | Sigma Total Knee System | K950010 | 5/15/1995 | | Sigma Total Knee System | K944538 | 9/26/1995 | | Sigma Total Knee System | K961685 | 7/10/1996 | | Sigma Total Knee System | K961685 | 7/10/1996 | | Sigma Total Knee System | K971189 | 7/17/1997 | | Sigma Total Knee System | K971189 | 7/17/1997 | | Sigma Total Knee System | K082500 | 11/18/2008 | | Attune Total Knee System | K101433 | 12/10/2010 | #### Non-Clinical Testing: The following testing was performed to demonstrate the substantial equivalence of the TruMatch™ Patient Specific Instruments to the predicate devices. - TruMatch™ Dimensional Stability Test . - . Cadaver Accuracy Study - Design Process and Design Software Repeatability Study . - Software Validation and Verification Summary � The tests results demonstrate that all acceptance criteria were met. #### Clinical Testing: Clinical testing was not necessary to determine substantial equivalence between the TruMatch™ Patient Specific Instruments and the predicate devices. {2}------------------------------------------------ # DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized depiction of a bird-like symbol with three curved lines, positioned to the right of the text. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" is arranged in a circular fashion around the symbol. Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002 DePuy Orthopaedics, Inc. % Ms. Nancy S. Friddle Project Manager, Regulatory Affairs 700 Orthopaedic Drive Warsaw. Indiana 46581-0988 AUG 1 6 2011 Re: K110397 Trade/Device Name: DePuy TruMatch™ Patient Specific Instruments Regulation Number: 21 CFR 888.3560 Regulation Name: Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis Regulatory Class: Class II Product Code: JWH, OOG Dated: June 15, 2011 Received: June 16, 2011 Dear Ms. Friddle: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. Iisting of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA 's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807): labeling (21 CFR Part 801): medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set {3}------------------------------------------------ Page 2 - Ms. Nancy S. Friddle forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fdgg.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/wcm115809.html for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportalProblem/default.htm for the CDRH 's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Sincerely yours Mark N. Melkerson Director Division of Surgical, Orthopedic, and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ # K110397 ### 2. INDICATIONS FOR USE 510(k) Number (if known): Device Name: DePuy TruMatch™ Patient Specific Instruments Indications for Use: The TruMatch™ Patient Specific Instruments are intended to be used as patient-specific surgical instrumentation to assist in the positioning of a joint replacement component intra-operatively and in guiding the marking of bone before cutting. The anatomical landmarks necessary for the creation of the TruMatch™ Patient Specific Instruments must be present and identifiable on CT. The TruMatch™ Patient Specific Instruments are intended for use with Sigma® Total Knee Implants and Attune™ Total Knee Implants and their cleared indications for use. The TruMatch™ Patient Specific Instruments are intended for single use only. Prescription Use X (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use (21 CFR 801 Subpart C) # (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) ### Concurrence of CDRH, Office of Device Evaluation (ODE) for M. Melleuson (Division Sign Oft) Division of Surgical, Orthopedic, and Restorative Devices 510(k) Number K110397
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...