← Product Code [MQV](/submissions/OR/subpart-d%E2%80%94prosthetic-devices/MQV) · K172497

# NuVasive AttraX Scaffold (K172497)

_Nu Vasive, Incorporated · MQV · Nov 24, 2017 · Orthopedic · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/OR/subpart-d%E2%80%94prosthetic-devices/MQV/K172497

## Device Facts

- **Applicant:** Nu Vasive, Incorporated
- **Product Code:** [MQV](/submissions/OR/subpart-d%E2%80%94prosthetic-devices/MQV.md)
- **Decision Date:** Nov 24, 2017
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 888.3045
- **Device Class:** Class 2
- **Review Panel:** Orthopedic
- **Attributes:** Therapeutic

## Intended Use

AttraX Scaffold is an implant intended to fill bony voids or gaps of the skeletal system (i.e., posterolateral spine and pelvis). AttraX Scaffold must be used in combination with either autogenous bone or autogenous bone marrow aspirate in the posterolateral spine. These osseous defects may be surgically created or the result of traumatic injury to the bone and are not intrinsic to the stability of the bony structure. AttraX Scaffold resorbs and is replaced with bone during the healing process.

## Device Story

AttraX Scaffold is an osteoconductive, resorbable bone void filler; composed of ceramic granules premixed with purified type I bovine collagen. Device is provided sterile for single-use. Clinician hydrates scaffold with saline or biological fluids; applies directly to bone defects or molds to fit defect contours. Acts as a scaffold for bone growth; resorbs and is replaced by bone during healing. Used in surgical settings for skeletal system voids; specifically posterolateral spine and pelvis. Benefits patient by facilitating bone repair in non-structural defects.

## Clinical Evidence

Bench testing only; no human clinical trials. Physicochemical and crystallographic characterization performed. Biocompatibility demonstrated via ISO 10993 testing. Bacterial endotoxin testing performed via LAL method. In vivo animal data provided to support equivalence to predicates.

## Technological Characteristics

Resorbable calcium salt bone void filler. Materials: ceramic granules and purified type I bovine collagen. Form factor: moldable scaffold. Sterilization: sterile, single-use. No software or electrical components.

## Regulatory Identification

A resorbable calcium salt bone void filler device is a resorbable implant intended to fill bony voids or gaps of the extremities, spine, and pelvis that are caused by trauma or surgery and are not intrinsic to the stability of the bony structure.

## Special Controls

*Classification.* Class II (special controls). The special control for this device is the FDA guidance document entitled “Class II Special Controls Guidance: Resorbable Calcium Salt Bone Void Filler Device; Guidance for Industry and FDA.” See § 888.1(e) of this chapter for the availability of this guidance.

## Predicate Devices

- NuVasive Formagraft Collagen Bone Graft Matrix ([K050789](/device/K050789.md))
- NuVasive AttraX Putty ([K151584](/device/K151584.md))
- NuVasive AttraX Granules ([K090641](/device/K090641.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Image /page/0/Picture/0 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health & Human Services logo. To the right of that is the FDA logo, which consists of the letters "FDA" in a blue square, followed by the words "U.S. FOOD & DRUG" in blue, with the word "ADMINISTRATION" underneath.

November 24, 2017

NuVasive, Incorporated Martin Yahiro, M.D. Director, Medical Affairs 7475 Lusk Boulevard San Diego, California 92121

Re: K172497

Trade/Device Name: NuVasive® AttraX® Scaffold Regulation Number: 21 CFR 888.3045 Regulation Name: Resorbable calcium salt bone void filler device Regulatory Class: Class II Product Code: MQV Dated: November 6, 2017 Received: November 7, 2017

Dear Dr. Yahiro:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

{1}------------------------------------------------

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/) and CDRH Learn (http://www.fda.gov/Training/CDRHLearn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (http://www.fda.gov/DICE) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).

Sincerely,

# Mark N. Melkerson -S

Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

# Indications for Use

Form Approved: OMB No. 0910-0120 Expiration Date: January 31, 2017 See PRA Statement below.

510(k) Number (if known) K172497

Device Name NuVasive® AttraX® Scaffold

Indications for Use (Describe)

AttraX Scaffold is an implant intended to fill bony voids or gaps of the skeletal system (i.e., posterolateral spine and pelvis). AttraX Scaffold must be used in combination with either autogenous bone or autogenous bone marrow aspirate in the posterolateral spine. These osseous defects may be surgically created or the result of traumatic injury to the bone and are not intrinsic to the stability of the bony structure. AttraX Scaffold resorbs and is replaced with bone during the healing process.

## Type of Use (Select one or both, as applicable)

2 Prescription Use (Part 21 CFR 801 Subpart D)

Over-The-Counter Use (21 CFR 801 Subpart C)

# PLEASE DO NOT WRITE BELOW THIS LINE – CONTINUE ON A SEPARATE PAGE IF NEEDED.

## FOR FDA USE ONLY

Concurrence of Center for Devices and Radiological Health (CDRH) (Signature)

This section applies only to requirements of the Paperwork Reduction Act of 1995.

## *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

{3}------------------------------------------------

# 510(k) Summary

K172497

In accordance with Title 21 of the Code of Federal Regulations, Part 807, and in particular 21 CFR §807.92, the following summary of information is provided:

#### Submitted by: A.

Martin Yahiro, M.D. Director, Medical Affairs NuVasive, Incorporated 7475 Lusk Blvd. San Diego, California 92121 Telephone: (858) 909-1800

Date Prepared: November 6, 2017

#### B. Device Name

| Trade or Proprietary Name: | NuVasive® AttraX® Scaffold                      |
|----------------------------|-------------------------------------------------|
| Common or Usual Name:      | Filler, Bone Void, Calcium Compound             |
| Classification Name:       | Resorbable Calcium Salt Bone Void Filler Device |

| Device Class:   | Class II          |
|-----------------|-------------------|
| Classification: | 21 CFR § 888.3045 |
| Product Code:   | MQV               |

#### C. Predicate Devices

The subject NuVasive AttraX Scaffold substantially equivalent to the primary predicate device, NuVasive Formagrafi™ Collagen Bone Graft Matrix (K050789), and additional predicates NuVasive AttraX Putty (K151584) and NuVasive AttraX Granules' (K090641).

#### D. Device Description

The subject AttraX Scaffold, is an osteoconductive and resorbable bone void filler designed for use in the skeletal system. AttraX Scaffold consists of ceramic granules premixed with purified type I bovine collagen. The ceramic granules are identical to those cleared as CuriOs (K090641; herein after referred to by the commercial name as AttraX Granules) and identical to the granules within AttraX Putty (K151584). The collagen binder used in AttraX Scaffold is manufactured from the same source material as that of the primary predicate Formagraft Collagen Bone Graft Matrix (K050789). AttraX Scaffold will be provided sterile in singleuse packages. Once hydrated with biological fluids or saline, AttraX Scaffold can be applied directly to bone defects or molded to fit the contours of complex bone defects.

<sup>1</sup> AttraX Granules is the commercial name for CuriOs™

{4}------------------------------------------------

#### E. Indications for Use

AttraX Scaffold is an implant intended to fill bony voids or gaps of the skeletal system (i.e., posterolateral spine and pelvis). AttraX Scaffold must be used in combination with either autogenous bone or autogenous bone marrow aspirate in the posterolateral spine. These osseous defects may be surgically created or the result of traumatic injury to the bone and are not intrinsic to the stability of the bony structure. AttraX Scaffold resorbs and is replaced with bone during the healing process.

#### F. Technological Characteristics

As was established in this submission, the subject AttraX Scaffold is substantially equivalent to other predicate devices cleared by the FDA for commercial distribution in the United States. The subject device was shown to be substantially equivalent and have the same technological characteristics to its predicate devices through comparison in areas including design, intended use, material composition, and function. This device does not contain software or electrical equipment.

#### G. Performance Data

Characterization of AttraX Scaffold has been conducted in compliance with Guidance for Industry and FDA Staff - Class II Special Controls Guidance Document: Resorbable Calcium Salt Bone Void Filler Device (Document issued on: June 2, 2003) and the requirements of other applicable standards. Bench-top testing was preformed to evaluate the physicochemical and crystallographic characteristics of AttraX Scaffold. Data to support the substantial equivalence of the AttraX Scaffold to its predicates Formagraft and AttraX Putty, were provided by in vivo animal data in the intended use. The biocompatibility of the AttraX Scaffold is demonstrated by ISO 10993 testing and the long history of clinical use of the collagen/calcium phosphate materials for the same intended use. Bacterial endotoxin testing was performed using the limulus amebocyte lysate (LAL) method and showed that the device meets the endotoxin limits of established guidelines.

#### H. Conclusions

Based on the indications for use, technological characteristics, and performance comparison to its predicate devices, the subject AttraX Scaffold has been shown to be substantially equivalent to the legally marketed predicate devices Formagraft, AttraX Putty, and AttraX Granules.

---

**Source:** [https://fda.innolitics.com/submissions/OR/subpart-d%E2%80%94prosthetic-devices/MQV/K172497](https://fda.innolitics.com/submissions/OR/subpart-d%E2%80%94prosthetic-devices/MQV/K172497)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
