EBI SPINELINK SYSTEM

K964533 · Electro-Biology, Inc. · MNH · Apr 9, 1997 · Orthopedic

Device Facts

Record IDK964533
Device NameEBI SPINELINK SYSTEM
ApplicantElectro-Biology, Inc.
Product CodeMNH · Orthopedic
Decision DateApr 9, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3070
Device ClassClass 2
AttributesTherapeutic

Intended Use

The EBI SpineLink™ System (severe spondylolisthesis indication) is intended for patients: (a) having severe spondylolisthesis (Grades 3 and 4) of the fifth lumbar - first sacral (L5-S1) vertebral joint; (b) who are receiving fusions using autogenous bone graft only; (c) who are having the device fixed or attached to the lumbar and sacral spine; and (d) who are having the device removed after the development of a solid fusion mass. The screws of the system are limited to L3-S1 or iliac screw fixation.

Device Story

Posterior pedicle spinal system; consists of fixed and polydirectional pedicle/sacral screws, interconnecting links, lock nuts, and washers. Used by surgeons in clinical settings for spinal stabilization during fusion procedures. Device provides mechanical fixation to lumbar and sacral spine; intended for removal following solid fusion mass development. Benefits include stabilization of severe spondylolisthesis.

Clinical Evidence

Bench testing only; no clinical data provided. Bench testing compared system performance against predicate devices to verify functional requirements.

Technological Characteristics

Materials: Ti-6Al-4V ELI (ASTM F136); optional TiN coating. Components: fixed/polydirectional pedicle/sacral screws (5.5-7.5 mm diameter), interconnecting links, lock nuts, washers. Mechanical fixation system.

Indications for Use

Indicated for patients with severe spondylolisthesis (Grades 3 and 4) at the L5-S1 vertebral joint requiring fusion with autogenous bone graft. Device fixation limited to L3-S1 or iliac screw placement.

Regulatory Classification

Identification

(1) Rigid pedicle screw systems are comprised of multiple components, made from a variety of materials that allow the surgeon to build an implant system to fit the patient's anatomical and physiological requirements. Such a spinal implant assembly consists of a combination of screws, longitudinal members (e.g., plates, rods including dual diameter rods, plate/rod combinations), transverse or cross connectors, and interconnection mechanisms (e.g., rod-to-rod connectors, offset connectors).(2) Semi-rigid systems are defined as systems that contain one or more of the following features (including but not limited to): Non-uniform longitudinal elements, or features that allow more motion or flexibility compared to rigid systems.

Special Controls

*Classification.* (1) Class II (special controls), when intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: severe spondylolisthesis (grades 3 and 4) of the L5-S1 vertebra; degenerative spondylolisthesis with objective evidence of neurologic impairment; fracture; dislocation; scoliosis; kyphosis; spinal tumor; and failed previous fusion (pseudarthrosis). These pedicle screw spinal systems must comply with the following special controls:(i) Compliance with material standards; (ii) Compliance with mechanical testing standards; (iii) Compliance with biocompatibility standards; and (iv) Labeling that contains these two statements in addition to other appropriate labeling information: “Warning: The safety and effectiveness of pedicle screw spinal systems have been established only for spinal conditions with significant mechanical instability or deformity requiring fusion with instrumentation. These conditions are significant mechanical instability or deformity of the thoracic, lumbar, and sacral spine secondary to severe spondylolisthesis (grades 3 and 4) of the L5-S1 vertebra, degenerative spondylolisthesis with objective evidence of neurologic impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudarthrosis). The safety and effectiveness of these devices for any other conditions are unknown.” “Precaution: The implantation of pedicle screw spinal systems should be performed only by experienced spinal surgeons with specific training in the use of this pedicle screw spinal system because this is a technically demanding procedure presenting a risk of serious injury to the patient.” (2) Class II (special controls), when a rigid pedicle screw system is intended to provide immobilization and stabilization of spinal segments in the thoracic, lumbar, and sacral spine as an adjunct to fusion in the treatment of degenerative disc disease and spondylolisthesis other than either severe spondylolisthesis (grades 3 and 4) at L5-S1 or degenerative spondylolisthesis with objective evidence of neurologic impairment. These pedicle screw systems must comply with the following special controls: (i) The design characteristics of the device, including engineering schematics, must ensure that the geometry and material composition are consistent with the intended use. (ii) Non-clinical performance testing must demonstrate the mechanical function and durability of the implant. (iii) Device components must be demonstrated to be biocompatible. (iv) Validation testing must demonstrate the cleanliness and sterility of, or the ability to clean and sterilize, the device components and device-specific instruments. (v) Labeling must include the following: (A) A clear description of the technological features of the device including identification of device materials and the principles of device operation; (B) Intended use and indications for use, including levels of fixation; (C) Identification of magnetic resonance (MR) compatibility status; (D) Cleaning and sterilization instructions for devices and instruments that are provided non-sterile to the end user; and (E) Detailed instructions of each surgical step, including device removal. (3) Class II (special controls), when a semi-rigid system is intended to provide immobilization and stabilization of spinal segments in the thoracic, lumbar, and sacral spine as an adjunct to fusion for any indication. In addition to complying with the special controls in paragraphs (b)(2)(i) through (v) of this section, these pedicle screw systems must comply with the following special controls: (i) Demonstration that clinical performance characteristics of the device support the intended use of the product, including assessment of fusion compared to a clinically acceptable fusion rate. (ii) Semi-rigid systems marketed prior to the effective date of this reclassification must submit an amendment to their previously cleared premarket notification (510(k)) demonstrating compliance with the special controls in paragraphs (b)(2)(i) through (v) and paragraph (b)(3)(i) of this section.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} APR-04-1997 13:01 EBIMS THIRD FLOOR, CORP. 1 201 299 0906 P.19 # EBI Electro Biology *Enhancing Bone Healing through Applied Science* APR - 9 1997 K964533 ## 510(k) Summary of Safety & Effectiveness This 510(k) Summary of Safety and Effectiveness for the EBI SpineLink™ System is provided as required per Section 513(1)(3) of the Food, Drug and Cosmetic Act. 1. Submitter: Electro-Biology, Inc. 6 Upper Pond Road Parsippany, NJ 07054 Contact Person: Jon Caparotta Telephone: (201) 299-9022 Date prepared: April 4, 1997 2. Proprietary Name: EBI SpineLink™ System Common Name: Posterior pedicle spinal system Classification Name: Spondylolisthesis Spinal Fixation Device System (Proposed) 3. Predicate or legally marketed devices that are substantially equivalent: - Webb-Morley Spine System - Electro-Biology, Inc. - TSRH® Spinal System - Sofamor Danek - Dyna-Lok® Spine System - Sofamor Danek - Isola® Spine System - AcroMed Corporation - VSP® Plating System - AcroMed Corporation - KSF Spinal Fixator - Tornier SA 4. Description of the device: The EBI SpineLink™ System is a posterior pedicle system consisting of fixed and polydirectional pedicle/sacral screws (available in diameters from 5.5 to 7.5 mm), various types of interconnecting links, lock nuts, and different types of washers. Intended Use: The EBI SpineLink™ System (severe spondylolisthesis indication) is intended for patients: (a) having severe spondylolisthesis (Grades 3 and 4) of the fifth lumbar - first sacral (L5-S1) vertebral joint; (b) who are receiving fusions using autogenous bone graft only; (c) who are having the device fixed or attached to the lumbar and sacral spine; and (d) who are having the device removed after the development of a solid fusion mass. The screws of the system are limited to L3-S1 or iliac screw fixation. 5. Materials: The components of the system are manufactured from Ti-6Al-4V ELI per ASTM F136. The components will be available with and without TiN coating. 6. Comparison of the technological characteristics of the device to predicate devices: There are no significant differences between EBI SpineLink™ System and other currently marketed spinal systems. It is substantially equivalent* to the predicate devices in regards to intended use, materials and function. Bench testing comparing the system to a predicate system demonstrated that the device complies with applicable standards and meets all of its functional requirements. *Any statement made in conjunction with this submission regarding a determination of substantial equivalence to any other product is intended only to relate to whether the product can be lawfully marketed without pre-market approval or reclassification and is not intended to be interpreted as an admission or any other type of evidence in patent infringement litigation. [Establishment Registration and Premarket Notification Procedures, Final Regulation, Preamble, August 23, 1977, FR 42520 (Docket No. 76N-0355).] Electro-Biology, Inc. - A Subsidiary of Biomet, Inc. 6 Upper Pond Road, Parsippany, NJ 07054-1079 • Telephone 201-299-9022 • Toll Free 800-526-2579 • Fax 201-299-0906
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...