TENODESIS SCREW, 5.5 MM, MODEL AR-1350-55

K011007 · Arthrex, Inc. · MBI · Jun 12, 2001 · Orthopedic

Device Facts

Record IDK011007
Device NameTENODESIS SCREW, 5.5 MM, MODEL AR-1350-55
ApplicantArthrex, Inc.
Product CodeMBI · Orthopedic
Decision DateJun 12, 2001
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3040
Device ClassClass 2
AttributesTherapeutic

Intended Use

The Arthrex Tenodesis Screw is intended for arthroscopic and limited mini-open surgeries requiring soft tissue fixation to bone for repair of shoulder, hand/wrist, foot/ankle, knee, and elbow.

Device Story

Manually operated surgical implant; titanium screw used for interference fixation of soft tissue grafts to bone. Used in arthroscopic or mini-open orthopedic surgeries (shoulder, elbow, wrist, ankle, knee). Surgeon inserts screw to secure tendon or ligament grafts. Provides mechanical fixation to facilitate healing. Benefits patient by stabilizing soft tissue during repair.

Clinical Evidence

No clinical data provided; substantial equivalence based on design and material similarity to legally marketed predicate devices.

Technological Characteristics

Titanium screw; #2 braided polyester suture. Manually operated mechanical fixation device. No energy source, software, or connectivity.

Indications for Use

Indicated for interference fixation of soft tissue grafts in shoulder, elbow, wrist, and ankle via open or arthroscopic surgery. Specific procedures include: Rotator Cuff, Bankart, SLAP, Biceps Tenodesis, AC separation, Deltoid, Capsular shift/reconstruction; Biceps reattachment, Tennis elbow, Ulnar/Radial collateral ligament reconstruction; Scapholunate ligament, Ulnar/Radial collateral ligament reconstruction; Lateral/Medial stabilization, Achilles tendon, Hallux Valgus, Midfoot, and Metatarsal ligament repair. Requires post-operative immobilization.

Regulatory Classification

Identification

A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ # 510(k) Summary 510(k) Number: KOHOOZ Contact Person: Ann Waterhouse, Regulatory Affairs Specialist Date Prepared: April 3, 2001 Trade/Proprietary Name: Tenodesis Screw Classification Name: Fastener, fixation, non-degradable, soft tissue Predicate Devices: Talon Anchor Snap-Pak by Mitek Products, RC Multisuture Bone Anchor Model 4453 bv Innovasive Devices, Inc., Multitak SS Buttons by Bonutti Research, KSEA Flipptack by Karl Storz Endoscopy-America, and Acumed Suture Anchor by Acumed, Inc. This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of 21 CFR 807.92. #### Intended Use: The Arthrex Tenodesis Screw is intended for arthroscopic and limited mini-open surgeries requiring soft tissue fixation to bone for repair of shoulder, hand/wrist, foot/ankle, knee, and elbow. #### Description: The Arthrex Tenodesis Screw is a manually operated surgical implant intended for suture fixation in the repair of tendons and ligaments. The implant is constructed of titanium and the suture is composed of #2 braided polyester. These components are used in a wide variety of cleared medical devices and implants of this type. #### Substantial Equivalence: The Arthrex, Inc. Tenodesis Screw is substantially equivalent to predicate devices where the basic features and intended uses are the same. Minor differences between the Tenodesis Screw and predicate devices do not raise any questions concerning safety and effectiveness and have no apparent effect on the performance, function, or intended use of this device. {1}------------------------------------------------ Image /page/1/Picture/1 description: The image shows the seal of the Department of Health & Human Services - USA. The seal is circular and contains the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is a stylized image of an eagle with three stripes across its body. Public Health Service JUN 1 2 2001 Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 Ms. Ann Waterhouse Regulatory Affairs Specialist Arthrex, Inc. 2885 South Horseshoe Drive Naples, Florida 34104 Re: K011007 Trade Name: Arthrex Tenodesis Screw, 5.5 mm Regulation Number: 888.3040 Regulatory Class: II Product Code: MBI Dated: April 3, 2001 Received: April 4, 2001 Dear Ms. Waterhouse: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general control provisions of the Act. The general control provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. {2}------------------------------------------------ Page 2 - Ms. Ann Waterhouse If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address "http://www.fda.gov/cdrh/dsmamain.html". Sincerely yours, BBhlllellorff Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {3}------------------------------------------------ ## 510(k) Number (if known): K011007 ## Device Name: Tenodesis Screw, 5.5 mm Indications for Use: The Arthrex Tenodesis Screw, 5.5 mm for fixation of tissue grafts is intended for interference fixation of soft tissue grafts in the shoulder, elbow, wrist, and ankle. These surgeries will be performed by both open and arthroscopic means. - Rotator Cuff Repair, Bankart Repair, SLAP Lesion Repair, Biceps Shoulder. Tenodesis, Acromio-Clavicular Separation Repair, Deltoid Repair, Capsular Shift or Capsulolabral Reconstruction. - Biceps Tendon Reattachment, Tennis Elbow Repair, Ulnar or Elbow: Radial Collateral Ligament Reconstruction - Wrist: Scapholunate Ligament Reconstruction, Ulnar Collateral Ligament Reconstruction, Radial Collateral Ligament Reconstruction - Lateral Stabilization, Medial Stabilization, Achilles Tendon Repair, Foot/Ankle: Hallux Valgus Reconstruction, Midfoot Reconstruction, Metatarsal Ligament Repair *This system is to be used in association with adequate post-operative immobilization. ### (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Mmkheunston an (Division Sign-Off) Division of General. Restorative and Neurological Devices (Option Format 3-10-98) 510(k) Number K011007
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...