REGENEREX ULTRA POROUS CONSTRUCT-FEMORAL AND TIBIAL KNEE AUGMENTS
K053505 · Biomet Manufacturing, Inc. · MBH · Aug 14, 2006 · Orthopedic
Device Facts
| Record ID | K053505 |
| Device Name | REGENEREX ULTRA POROUS CONSTRUCT-FEMORAL AND TIBIAL KNEE AUGMENTS |
| Applicant | Biomet Manufacturing, Inc. |
| Product Code | MBH · Orthopedic |
| Decision Date | Aug 14, 2006 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 888.3565 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Intended Use
Femoral and Tibial Augments are intended for: - Painful and disabled knee joint resulting from osteoarthritis, theumatoid arthritis, traumatic arthritis 1. where one or more compartments are involved. - 2. Correction of varus, valgus, or posttraumatic deformity. - 3. Correction or revision of unsuccessful osteotomy, arthrodesis, or failure of previous joint replacement procedure. Cemented and uncemented applications The Regenerex™ femoral augments are indicated for use with the Vanguard™ Total Knee System. The Regenerex™ tibial augments are indicated for use with standard and offset Biomet® Tibial Trays. The OSS Augments are intended for: - 1. Painful and disabled joint resulting from avascular necrosis, osteoarthritis, rheumatoid arthritis, or traumatic arthritis - 2. Correction of varus, valqus, or posttraumatic deformity - 3. Correction or revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement - 4. Ligament deficiencies - 5. Tumor Resection - 6. Revision of previously failed total joint arthroplasty - 7. Trauma These are single use implants These devices are for cemented use only
Device Story
Regenerex™ Ultra Porous Construct- Titanium Knee Augments are orthopedic implants designed to augment femoral and tibial components in total knee arthroplasty. Augments attach to Biomet® tibial base plates and femoral components via bolts, cement, or both. Femoral augments available in nine sizes (5-15mm thickness); tibial augments available in 10° wedge and block forms. OSS-specific augments include anterior flange and monoblock/block options for tumor/salvage cases. Used in clinical settings by orthopedic surgeons during knee replacement or revision procedures. Implants provide structural support to address bone loss or deformity, facilitating joint reconstruction and improving patient mobility. Single-use devices.
Clinical Evidence
No clinical data provided as a basis for substantial equivalence. Bench testing only.
Technological Characteristics
Titanium-based porous construct knee augments. Designed for interface with Biomet femoral and tibial components. Available in various sizes and thicknesses (5mm-20mm). Attachment via bolts or cement. Single-use. Uncemented and cemented application options depending on specific augment type.
Indications for Use
Indicated for patients with painful/disabled knee joints due to osteoarthritis, rheumatoid arthritis, traumatic arthritis, or avascular necrosis; requiring correction of varus, valgus, or posttraumatic deformity; revision of failed osteotomy, arthrodesis, or joint replacement; ligament deficiencies; tumor resection; or trauma. OSS augments are for cemented use only.
Regulatory Classification
Identification
A knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis is a device intended to be implanted to replace a knee joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device is designed to achieve biological fixation to bone without the use of bone cement. This identification includes fixed-bearing knee prostheses where the ultra high molecular weight polyethylene tibial bearing is rigidly secured to the metal tibial base plate.
Special Controls
*Classification.* Class II (special controls). The special control is FDA's guidance: “Class II Special Controls Guidance Document: Knee Joint Patellofemorotibial and Femorotibial Metal/Polymer Porous-Coated Uncemented Prostheses; Guidance for Industry and FDA.” See § 888.1 for the availability of this guidance.
Predicate Devices
- Maxim® Accel Knee System (K023546)
- MCK Knee System (K915132)
- Trabecular Metal Knee System Augments (K040487)
- NexGen Complete Knee Solution Trabecular Metal (K024161)
- Oncology Salvage System (K002757)
Related Devices
- K072336 — REGENEREX POROUS TITANIUM SLEEVE AUGMENTS · Biomet Manufacturing Corp · Nov 5, 2007
- K024161 — NEXGEN COMPLETE KNEE SOLUTION - TRABECULAR METAL AUGMENTS · Implex Corp. · Jan 15, 2003
- K152494 — Zimmer NexGen Complete Knee Solution Tibial and Femoral Augments · Zimmer, Inc. · Nov 25, 2015
- K162775 — Legion Cone System · Smith & Nephew, Inc. · Jan 13, 2017
- K143393 — Triathlon Tritanium Cone Augments · Stryker Orthopaedics · Jan 13, 2015
Submission Summary (Full Text)
{0}------------------------------------------------
K053575 1/2
Image /page/0/Picture/1 description: The image shows the word "BIOMET" in a bold, sans-serif font. The letters are outlined in black, with the interior of the letters being white. The letters are all capitalized and evenly spaced. The overall impression is one of a strong, modern logo.
AUG 1 4 2006
Applicant/Sponsor: Biomet Manufacturing Corp.
Contact Person: Tracy Bickel Johnson, RAC
Proprietary Name: Regenerex™ Ultra Porous Construct- Titanium Knee Augments
Common Name: Knee Augments
Classification Name: - prosthesis, knee, patello/femorotibial, semi-constrained, cemented, polymer/metal/polymer (888.3560) -prosthesis, knee, patello/femorotibial, semi-constrained, uncemented, porous, coated, polymer/metal/polymer (888.3565) -prosthesis, knee, femorotibial, constrained, cemented, metal/polymer (888.3510)
Legally Marketed Devices To Which Substantial Equivalence Is Claimed: Maxim® Accel Knee System- K023546 (Biomet, Inc.); MCK Knee System- K915132 (Biomet, Inc.); Trabecular Metal Knee System Augments- K040487 (Zimmer Holdings); NexGen Complete Knee Solution Trabecular Metal- K024161 (Zimmer Holdings); Oncology Salvage System- K002757 (Biomet, Inc.)
Device Description: The Regenerex™ Ultra Porous Construct- Titanium Knee Augments are designed for attachment to selected commercially available Biomet® tibial base plates and femoral components using bolts, cement or a combination of both (depending on the augment).
The augments are manufactured to interface with selected femoral and tibial Biomet® components. The femoral augments come in nine (9) different sizes that correspond with the sizes of the femoral components. The thickness options for the femoral augments vary from 5mm to 15mm. The tibial augments are available in 10° wedge and block form. The block augments are available in three (3) thicknesses for nine (9) tibial sizes. The OSS femoral augments are available in a 3,5mm thick anterior flange augment. The OSS tibial augments are available in monoblock and block form. The monoblocks are only available in 10mm thicknesses for three tibial sizes, while the block augments are available in 10mm and 20 mm sizes for three tibial sizes.
#### Intended Use:
Femoral and Tibial Augments are intended for:
- Painful and disabled knee joint resulting from osteoarthritis, theumatoid arthritis, traumatic arthritis 1. where one or more compartments are involved.
- 2. Correction of varus, valgus, or posttraumatic deformity.
- 3. Correction or revision of unsuccessful osteotomy, arthrodesis, or failure of previous joint replacement procedure.
Cemented and uncemented applications
The Regenerex™ femoral augments are indicated for use with the Vanguard™ Total Knee System.
The Regenerex™ tibial augments are indicated for use with standard and offset Biomet® Tibial Trays.
MAILING ADDRESS 19 - P.O. Box 587
트
SHIPPING ADDRESS 56 E. Bell Drive Warsaw, IN 46582
■
()FFICE: 574.267.6639
I·AX 574.267.8137
E-MAIL biomet@biomet.com
{1}------------------------------------------------
Image /page/1/Picture/0 description: The image shows handwritten text that appears to be a combination of letters and numbers. The text includes 'K653525' followed by '2/2'. The handwriting is somewhat stylized, with some characters slightly distorted or connected.
### 510(k) Summary Biomet Manufacturing Corp. Regenerex™ Ultra Porous Construct- Titanium Knee Augments
The OSS Augments are intended for:
- 1. Painful and disabled joint resulting from avascular necrosis, osteoarthritis, rheumatoid arthritis, or traumatic arthritis
- 2. Correction of varus, valqus, or posttraumatic deformity
- 3. Correction or revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement
- 4. Ligament deficiencies
- 5. Tumor Resection
- 6. Revision of previously failed total joint arthroplasty
- 7. Trauma
These are single use implants These devices are for cemented use only
Summary of Technologies: The technological characteristics (material modification, design, sizing, indications) of the Regenerex™ Ultra Porous Construct- Titanium Knee Augments are similar to or identical to the predicate devices.
Non-Clinical Testing: Non-clinical laboratory testing was performed to determine substantial equivalence. The results indicated that the device was functional within its intended use.
Clinical Testing: None provided as a basis for substantial equivalence.
All trademarks are property of Biomet, Inc. except for Hedrocel® and Tantalum, which are property of Zimmer Vinglex Corp.)
{2}------------------------------------------------
Image /page/2/Picture/12 description: The image is a black and white logo for the Department of Health and Human Services, USA. The logo features a stylized eagle with three lines forming its wings and body. The words "DEPARTMENT OF HEALTH AND HUMAN SERVICES, USA" are arranged in a circular pattern around the eagle.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Biomet Manufacturing, Inc % Ms. Tracy Bickel Johnson, RAC Manager, Regulatory Affairs P.O. Box 587 Warsaw, Indiana 46581-0587
Received: May 16, 2006
AUG 1 4 2006
Re: K053505
Trade/Device Name: Regenerex™ Ultra Porous Construct -- Titanium OSS Knee Augments Regulation Number: 21 CFR 888.3565 Regulation Name: Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis Regulatory Class: Class II Product Code: MBH, KRO, JWH Dated: May 15, 2006
Dear Ms. Johnson:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k)
{3}------------------------------------------------
Page 2 - Ms. Tracy Bickel Johnson, RAC
premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0210 Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours.
Barbara Buell
Mark N. Melkerson Director Division of General, Restorative, and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
K053505 (1)/2
# Indications for Use
510(k) Number (if known):
Device Name: Regenerex™ Ultra Porous Construct- Femoral and Tibial Knee Augments
Indications For Use:
- Painful and disabled knee joint resulting from osteoarthritis, rheumatoid arthritis, 1. traumatic arthritis where one or more compartments are involved.
- Correction of varus, valgus, or posttraumatic deformity. 2.
- Correction or revision of unsuccessful osteotomy, arthrodesis, or failure of previous ന് joint replacement procedure.
Cemented and uncemented applications
The Regenerex™ femoral augments are indicated for use with the Vanguard™ Total Knee System.
The Regenerex™ tibial augments are indicated for use with standard and offset Biomet® Tibial Trays.
> Prescription Use __ (Part 21 CFR 801 Subpart D) AND/OR
Over-The-Counter Use_ NO (21 CFR 807 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Soubrie buclund to oul.
Division of General, Restorative, and Neurological Devices
510(k) Number k053505
Page 1 of 2
{5}------------------------------------------------
Ko 53505 (2)/2
## Indications for Use
510(k) Number (if known):
Device Name: Regenerex™ Ultra Porous Construct- Titanium OSS Knee Augments
Indications For Use:
- 1. Painful and disabled joint resulting from avascular necrosis, osteoarthritis, rheumatoid arthritis, or traumatic arthritis
- 2. Correction of varus, valgus, or posttraumatic deformity.
- 3. Correction or revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement
- 4. Ligament deficiencies
- 5. Tumor Resection
- 6. Revision of previously failed total joint arthroplasty
- 7. Trauma
These are single use implants These devices are for cemented use only
Prescription Use × (Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use (21 CFR 807 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Soubare Buelum
Division of General, Restorative, and Neurological Devices
Page 2 of 2
510(k) Number K053505